Bo Liu

Dr. Bo Liu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
WCWei Chen
Wei Chen
ZYZhe Yi
Zhe Yi
LLLincoln Jian Rong Lim
Lincoln Jian Rong Lim
RLRebecca Qian Ru Lim
Rebecca Qian Ru Lim
AZAijie Zhang
Aijie Zhang
BLBo Liu
Bo Liu
In recent decades, there has been ongoing development in the application of computer vision (CV) in the medical field. As conventional contact-based physiological measurement techniques often restrict a patient’s mobility in the clinical environment, the ability to achieve continuous, comfortable and convenient monitoring is thus a topic of interest to researchers. One type of CV application is remote imaging photoplethysmography (rPPG), which can predict vital signs using a video or image. While contactless physiological measurement techniques have an excellent application prospect, the lack of uniformity or standardization of contactless vital monitoring methods limits their application in remote healthcare/telehealth settings. Several methods have been developed to improve this limitation and solve the heterogeneity of video signals caused by movement, lighting, and equipment. The fundamental algorithms include traditional algorithms with optimization and developing deep learning (DL) algorithms. This article aims to provide an in-depth review of current Artificial Intelligence (AI) methods using CV and DL in contactless physiological measurement and a comprehensive summary of the latest development of contactless measurement techniques for skin perfusion, respiratory rate, blood oxygen saturation, heart rate, heart rate variability, and blood pressure.

25 March 2024 in Heliyon
Verified
Journal Article
Open access
WCWei Chen
Wei Chen
LLLincoln Jian Rong Lim
Lincoln Jian Rong Lim
RLRebecca Qian Ru Lim
Rebecca Qian Ru Lim
ZYZhe Yi
Zhe Yi
JHJiaxing Huang
Jiaxing Huang
BLBo Liu
Bo Liu
Magnetic resonance imaging (MRI) is an indispensable medical imaging examination technique in musculoskeletal medicine. Modern MRI techniques achieve superior high-quality multiplanar imaging of soft tissue and skeletal pathologies without the harmful effects of ionizing radiation. Some current limitations of MRI include long acquisition times, artifacts, and noise. In addition, it is often challenging to distinguish abutting or closely applied soft tissue structures with similar signal characteristics. In the past decade, Artificial Intelligence (AI) has been widely employed in musculoskeletal MRI to help reduce the image acquisition time and improve image quality. Apart from being able to reduce medical costs, AI can assist clinicians in diagnosing diseases more accurately. This will effectively help formulate appropriate treatment plans and ultimately improve patient care. This review article intends to summarize AI's current research and application in musculoskeletal MRI, particularly the advancement of DL in identifying the structure and lesions of upper extremity joints in MRI images.

25 February 2025 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
MLMing Lu
Ming Lu
AZAijie Zhang
Aijie Zhang
YWYao Wang
Yao Wang
RLRebecca Qian Ru Lim
Rebecca Qian Ru Lim
WCWei Chen
Wei Chen
BLBo Liu
Bo Liu
Background: Postoperative flap monitoring is a labor-intensive task that relies heavily on the subjective judgment of skin color change by both medical and nursing staff. Human errors, such as misinterpretation of visual cues, may result in flap failure due to missed or delayed detection of vascular compromise. Objective: To simulate clinical situations of vascular compromise and investigate the feasibility of using an artificial intelligence (AI) model with skin color monitoring algorithms (SCMAs) and pulse wave monitoring algorithms (PWMAs) in identifying changes to site vascularity. Materials and Methods: A tourniquet machine was used on human participants to simulate clinical conditions of venous and arterial obstruction by applying 6 different pressure conditions (0, 40, 70, 100, 160, and 200 mm Hg). The tourniquet was placed 10 cm above each participant’s elbow crease, and each pressure condition was maintained for 3 minutes. The color changes of the participant’s forearm and arm were assessed by 5 clinical specialists of level 2 according to the Tang and Giddins classification, and the SCMAs and PWMAs were recorded as well with their respective algorithms. The results from the SCMAs were then compared with the manual assessments, while the results from the PWMAs were compared with the pulse oximeter readings. Results: The 100 mm Hg pressure condition simulated a clinical venous blockage, while the 200 mm Hg pressure condition simulated an arterial blockage. The results from the SCMAs and PWMAs correlated with manual assessments of skin color changes and pulse oximetry readings, respectively. The simulation of a venous compromise showed a gradual deepening of skin color, whereas an arterial obstruction demonstrated decreased peripheral oxygen saturation instead of significant changes to skin color. Conclusion: These AI algorithms are comparable with manual assessment and contact-based devices in identifying vascular compromise, which portends feasibility in future research and development of such technology.