Martine Breteler

Dr. Martine Breteler

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Injury
Verified
Journal Article
Open access
MBMartine Breteler
Martine Breteler
EKEline KleinJan
Eline KleinJan
LNLieke Numan
Lieke Numan
JRJelle P. Ruurda
Jelle P. Ruurda
RHRichard Van Hillegersberg
Richard Van Hillegersberg
TBTaco J. Blokhuis
Taco J. Blokhuis
Adverse events are common in high-risk surgical patients, but early detection is difficult. Recent innovations have resulted in wireless and 'wearable' sensors, which may capture patient deterioration at an early stage, but little is known regarding their ability to timely detect events. The objective of this study is to describe the ability of currently available wireless sensors to detect adverse events in high-risk patients. A descriptive analysis was performed of all vital signs trend data obtained during an observational comparison study of wearable sensors for vital signs monitoring in high-risk surgical patients during the initial days of recovery at a surgical step-down unit (SDU) and subsequent traumatology or surgical oncology ward. Heart rate (HR), respiratory rate (RR) and oxygen saturation (SpO2) were continuously recorded. Vital sign trend patterns of patients that developed adverse events were described and compared to vital sign recordings of patients without occurrence of adverse events. Two wearable patch sensors were used (SensiumVitals and HealthPatch), a bed-based mattress sensor (EarlySense) and a patient-worn monitor (Masimo Radius-7). Twenty adverse events occurred in 11 of the 31 patients included. Atrial fibrillation (AF) was most common (20%). The onset of AF was recognizable as a sudden increase in HR in all recordings, and all patients with new-onset AF after esophagectomy developed other postoperative complications. Patients who developed respiratory insufficiency showed an increase in RR and a decrease in SpO2, but an increase in HR was not always visible. In patients without adverse events, temporary periods of high HR and RR are observed as well, but these were transient and less frequent. Current systems for remote wireless patient monitoring on the ward are capable of detecting abnormalities in vital sign patterns in patients who develop adverse events. Remote patient monitoring may have potential to improve patient safety by generating early warnings for deterioration to nursing staff.

4 December 2020 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
MBMartine Breteler
Martine Breteler
LNLieke Numan
Lieke Numan
JRJelle Ruurda
Jelle Ruurda
RHRichard van Hillegersberg
Richard van Hillegersberg
SHSylvia van der Horst
Sylvia van der Horst
CKCor J Kalkman
Cor J Kalkman
Background: Hospital stays after major surgery are shorter than ever before. Although enhanced recovery and early discharge have many benefits, some complications will now first manifest themselves in home settings. Remote patient monitoring with wearable sensors in the first days after hospital discharge may capture clinical deterioration earlier but is largely uncharted territory. Objective: This study aimed to assess the technical feasibility of patients, discharged after esophagectomy, being remotely monitored at home with a wireless patch sensor and the experiences of these patients. In addition, we determined whether observing vital signs with a wireless patch sensor influences clinical decision making. Methods: In an observational feasibility study, vital signs of patients were monitored with a wearable patch sensor (VitalPatch, VitalConnect Inc) during the first 7 days at home after esophagectomy and discharge from hospital. Vital signs trends were shared with the surgical team once a day, and they were asked to check the patient’s condition by phone each morning. Patient experiences were evaluated with a questionnaire, and technical feasibility was analyzed on a daily basis as the percentage of data loss and gap durations. In addition, the number of patients for whom a change in clinical decision was made based on the results of remote vital signs monitoring at home was assessed. Results: Patients (N=20) completed 7 days each of home monitoring with the wearable patch sensor. Each of the patients had good recovery at home, and remotely observed vital signs trends did not alter clinical decision making. Patients appreciated that surgeons checked their vital signs daily (mean 4.4/5) and were happy to be called by the surgical team each day (mean 4.5/5). Wearability of the patch was high (mean 4.4/5), and no reports of skin irritation were mentioned. Overall data loss of vital signs measurements at home was 25%; both data loss and gap duration varied considerably among patients. Conclusions: Remote monitoring of vital signs combined with telephone support from the surgical team was feasible and well perceived by all patients. Future studies need to evaluate the impact of home monitoring on patient outcome as well as the cost-effectiveness of this new approach.

17 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HGHarriët MR van Goor
Harriët MR van Goor
MBMartine Breteler
Martine Breteler
KLKim van Loon
Kim van Loon
THTitus de Hond
Titus de Hond
JRJohannes B. Reitsma
Johannes B. Reitsma
KKkarin kaasjager
karin kaasjager
Background: To ensure availability of hospital beds and improve COVID-19 patients’ well-being during the ongoing pandemic, hospital care could be offered at home. Retrospective studies show promising results of deploying remote hospital care to reduce the number of days spent in the hospital, but the beneficial effect has yet to be established. Methods: We conducted a single centre, randomised trial from January to June 2021, including hospitalised COVID-19 patients who were in the recovery stage of the disease. Hospital care for the intervention group was transitioned to the patient’s home, including oxygen therapy, medication and remote monitoring. The control group received in-hospital care as usual. The primary endpoint was the number of hospital-free days during the 30 days following randomisation. Secondary endpoints included health care consumption during the follow-up period and mortality. Results: A total of 62 patients were randomised (31 control, 31 intervention). The mean difference in hospital-free days was 1.7 (26.7 control vs. 28.4 intervention, 95% CI of difference −0.5 to 4.2, p = 0.112). In the intervention group, the index hospital length of stay was 1.6 days shorter (95% CI −2.4 to −0.8, p < 0.001), but the total duration of care under hospital responsibility was 4.1 days longer (95% CI 0.5 to 7.7, p = 0.028). Conclusion: Remote hospital care for recovering COVID-19 patients is feasible. However, we could not demonstrate an increase in hospital-free days in the 30 days following randomisation. Optimising the intervention, timing, and identification of patients who will benefit most from remote hospital care could improve the impact of this intervention.

24 April 2019 in JMIR Formative Research
Verified
Journal Article
Open access
MBMartine Breteler
Martine Breteler
JJJoris H Janssen
Joris H Janssen
WSWilko Spiering
Wilko Spiering
CKCor J Kalkman
Cor J Kalkman
WSWouter van Solinge
Wouter van Solinge
Daan DohmenDaan Dohmen
Daan Dohmen
Background: Remote monitoring of physical activity in patients with chronic conditions could be useful to offer care professionals real-time assessment of their patient’s daily activity pattern to adjust appropriate treatment. However, the validity of commercially available activity trackers that can be used for telemonitoring purposes is limited. Objective: The purpose of this study was to test usability and determine the validity of 3 consumer-level activity trackers as a measure of free-living activity. Methods: A usability evaluation (study 1) and validation study (study 2) were conducted. In study 1, 10 individuals wore one activity tracker for a period of 30 days and filled in a questionnaire on ease of use and wearability. In study 2, we validated three selected activity trackers (Apple Watch, Misfit Shine, and iHealth Edge) and a fourth pedometer (Yamax Digiwalker) against the reference standard (Actigraph GT3X) in 30 healthy participants for 72 hours. Outcome measures were 95% limits of agreement (LoA) and bias (Bland-Altman analysis). Furthermore, median absolute differences (MAD) were calculated. Correction for bias was estimated and validated using leave-one-out cross validation. Results: Usability evaluation of study 1 showed that iHealth Edge and Apple Watch were more comfortable to wear as compared with the Misfit Flash. Therefore, the Misfit Flash was replaced by Misfit Shine in study 2. During study 2, the total number of steps of the reference standard was 21,527 (interquartile range, IQR 17,475-24,809). Bias and LoA for number of steps from the Apple Watch and iHealth Edge were 968 (IQR −5478 to 7414) and 2021 (IQR −4994 to 9036) steps. For Misfit Shine and Yamax Digiwalker, bias was −1874 and 2004, both with wide LoA of (13,869 to 10,121) and (−10,932 to 14,940) steps, respectively. The Apple Watch noted the smallest MAD of 7.7% with the Actigraph, whereas the Yamax Digiwalker noted the highest MAD (20.3%). After leave-one-out cross validation, accuracy estimates of MAD of the iHealth Edge and Misfit Shine were within acceptable limits with 10.7% and 11.3%, respectively. Conclusions: Overall, the Apple Watch and iHealth Edge were positively evaluated after wearing. Validity varied widely between devices, with the Apple Watch being the most accurate and Yamax Digiwalker the least accurate for step count in free-living conditions. The iHealth Edge underestimates number of steps but can be considered reliable for activity monitoring after correction for bias. Misfit Shine overestimated number of steps and cannot be considered suitable for step count because of the low agreement. Future studies should focus on the added value of remotely monitoring activity patterns over time in chronic patients.

8 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HGHarriët MR van Goor
Harriët MR van Goor
THTitus de Hond
Titus de Hond
KLKim van Loon
Kim van Loon
MBMartine Breteler
Martine Breteler
CKCor J. Kalkman
Cor J. Kalkman
KKkarin kaasjager
karin kaasjager
Background: Virtual hospital-at-home care might be an alternative to standard hospital care for patients with infectious diseases. In this study, we explore the potential for virtual hospital-at-home care and a potential design for this population. Methods: This was a retrospective cohort study of internal medicine patients suspected of infectious diseases, admitted between 1 January and 31 December 2019. We collected information on delivered care during emergency department visits, the first 24 h, between 24 and 72 h, and after 72 h of admission. Care components that could be delivered at home were combined into care packages, and the potential number of eligible patients per package was described. The most feasible package was described in detail. Results: 763 patients were included, mostly referred for general internal medicine (35%), and the most common diagnosis was lower respiratory tract infection (27%). The most frequently administered care components were laboratory tests, non-oral medication, and intercollegiate consultation. With a combination of telemonitoring, video consultation, non-oral medication administration, laboratory tests, oxygen therapy, and radiological diagnostics, 48% of patients were eligible for hospital-at-home care, with 35% already eligible directly after emergency department visits. Conclusion: While the potential for virtual hospital-at-home care is high, it depends greatly on which care can be arranged.

18 March 2025 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
MBMartine Breteler
Martine Breteler
ELEllen Leigard
Ellen Leigard
LHLisa C. Hartung
Lisa C. Hartung
JWJohn R. Welch
John R. Welch
DBDavid A. Brealey
David A. Brealey
CKCor J. Kalkman
Cor J. Kalkman
Continuous vital signs monitoring with wearable systems may improve early recognition of patient deterioration on hospital wards. The objective of this study was to determine whether the wearable Checkpoint Cardio’s CPC12S, can accurately measure heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), blood pressure (BP) and temperature continuously. In an observational multicenter method comparison study of 70 high-risk surgical patients admitted to high-dependency wards; HR, RR, SpO2, BP and temperature were simultaneously measured with the CPC12S system and with ICU-grade monitoring systems in four European hospitals. Outcome measures were bias and 95% limits of agreement (LoA). Clinical accuracy was assessed with Clarke Error Grid analyses for HR and RR. A total of 3,212 h of vital signs data (on average 26 h per patient) were analyzed. For HR, bias (95% LoA) of the pooled analysis was 0.0 (-3.5 to 3.4), for RR 1.5 (-3.7 to 7.5) and for SpO2 0.4 (-3.1 to 4.0). The CPC12S system overestimated BP, with a bias of 8.9 and wide LoA (-23.3 to 41.2). Temperature was underestimated with a bias of -0.6 and LoA of -1.7 to 0.6. Clarke Error Grid analyses showed that adequate treatment decisions regarding changes in HR and RR would have been made in 99.2% and 92.0% of cases respectively. The CPC12S system showed high accuracy for measurements of HR. The accuracy of RR, SpO2 were slightly overestimated and core temperature underestimated, with LoA outside the predefined clinical acceptable range. The accuracy of BP was unacceptably low.