In this paper, we developed a quick, economical and sensitive colorimetric strategy for copper ions (Cu2+) quantification via the redox response of MnO2 nanosheets with glutathione (GSH). This reaction consumed MnO2 nanosheets, which acted as a catalyst for the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) to a blue product (oxTMB). In the presence of Cu2+, the GSH was catalyzed to GSSG (oxidized glutathione), and the solution changed from colorless to deep blue. Under the optimum conditions, the absorption signal of the oxidized product (oxTMB) became proportional to Cu2+ concentration in the range from 10 to 300 nM with a detection limit of 6.9 nM. This detection system showed high specificity for Cu2+. Moreover, the system has been efficaciously implemented for Cu2+ detection in actual tap water samples. The layered-nanostructures of MnO2 nanosheets make it possess high chemical and thermal stability. TMB can be quickly oxidized within 10 min by the catalyzing of MnO2 nanosheets with high oxidase-like activity. There is no need of expensive reagents, additional H2O2 and complicated modification processes during the colorimetric assay. Therefore, the strategy primarily based on MnO2 nanosheets is promising for real-time, rapid and highly sensitive detection of Cu2+ under practical conditions.
A new fluorescence detection method for PO43− was developed through the in situ synthesis of cadmium sulfide quantum dots (CdS QDs). Without PO43−, the CdS QDs could not be effectively formed by only the S2− and Cd2+ in the solution. As a stabilizer, PO43− is an essential component to regulate the in situ synthesis of CdS QDs. The fluorescence intensity following the addition of different concentrations of PO43− was monitored for quantification. Under optimum conditions, the fluorescence intensity shows a linear relationship with concentrations ranging from 3.0 to 300 µM, and a detection limit of 2.9 µM. This assay was successfully employed to assess PO43− in tap water and wastewater. Compared with traditional methods, which require pre-synthesizing QDs and tethering them with recognition elements to achieve sample detection, the proposed method is simpler and quicker. It takes less than 5 min to complete PO43− detection.