Hariharan Ramakrishnan

Prof. Dr. Hariharan Ramakrishnan

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Contemporary Clinical Dentistry
Verified
Journal Article
Open access
PDF file
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
PTPriyadarshini Thilagar
Priyadarshini Thilagar
JSJayakrishnakumar Sampathkumar
Jayakrishnakumar Sampathkumar
CKChitraShankar Krishnan
ChitraShankar Krishnan
HRHariharan Ramasubramanian
Hariharan Ramasubramanian
NANs Azhagarasan
Ns Azhagarasan
Purpose: The purpose of this in vitro study was to comparatively evaluate the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate. Materials and Methods: A total of 30 heat pressed lithium disilicate ceramic discs of low translucency were fabricated with diameter 10mm and thickness of 1 mm, 1.3 mm and 1.6mm with each thickness consisting of 10 samples to be used in the study. Thirty Ni-Cr metal discs of diameter 10mm were used to simulate metallic substrates .The colour difference of the lithium disilicate ceramic disc before and after cementation were measured using CIE LAB system. Results: The mean colour difference (ΔE) of Group I,Group II, Group III before cementation with the Ni-Cr metal discs was 17.32,13.01 and 11.73 respectively. The mean colour difference (ΔE) of Group I,Group II, Group III after cementation with the Ni-Cr metal discs was 16.32,12.10, 11.05 respectively. Conclusion: The mean colour difference of the three groups were found to be more than the clinically acceptable perceptibility threshold (ΔE < 3.3) indicative of reduced masking ability of all the three groups of ceramic discs over metallic substrate used in this study.

1 October 2020 in Contemporary Clinical Dentistry
Verified
Journal Article
Open access
PDF file
AMAsish Martin
Asish Martin
NAN. S. Azhagarasan
N. S. Azhagarasan
MRMahadevan Ravichandran
Mahadevan Ravichandran
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
SKS. Jaya Krishnakumar
S. Jaya Krishnakumar
VMVallabh Mahadevan
Vallabh Mahadevan
Purpose: The purpose of this study was to evaluate the bioactivity of polyetheretherketone (PEEK) used as an implant material after surface modification by electron beam deposition of titanium. Materials and Methods: Twenty-two samples of PEEK were obtained from a single manufacturer, water jet sectioned, and divided randomly into two groups of eleven each (Group I and Group II). Eleven PEEK samples from Group II were coated with Grade II commercially pure titanium by electron beam deposition technique. One representative sample from each group was evaluated for surface roughness, topography and composition using three dimensional surface profilometer, scanning electron microscope coupled with energy dispersive X-ray (SEM-EDX) analysis. Simulated body fluid (SBF) was prepared and calcium (Ca) content in it was quantitatively analyzed by inductively coupled plasma mass spectrometry (ICP-MS) technique. Ten samples from each group were then immersed in SBF for a period of 21 days and amount of calcium depletion was analyzed to determine the bioactivity of two groups. Surface characteristics and elemental composition of immersed samples were analyzed by SEM-EDX and correlated with results of ICP-MS tests. The data obtained were then subjected to statistical analysis using independent t-test. Results: Group II samples showed a significant increase in surface roughness compared to Group I (P < 0.02). There were significant differences in Ca depletion of Group I and Group II samples when compared to preimmersion Ca content (P < 0.001). When compared between two Groups, Group II samples showed higher Ca depletion (P < 0.001). Conclusion: Within the limitations of this study, it was concluded that PEEK dental implants which were surface modified by electron beam deposition of titanium had enhanced bioactivity when compared to unmodified PEEK. Hence, they can serve as a valuable alternative to conventional dental implant materials.

1 January 2020 in Contemporary Clinical Dentistry
Verified
Journal Article
Open access
PDF file
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
MRManiamuthu Ragupathi
Maniamuthu Ragupathi
VMVallabh Mahadevan
Vallabh Mahadevan
NANs Azhagarasan
Ns Azhagarasan
SJS Jayakrishnakumar
S Jayakrishnakumar
Purpose: To comparatively evaluate the wear resistance of two different implant abutment materials with titanium implants after cyclic loading. Methodology: Two groups utilizing 20 titanium implants secured in resin blocks, in which 10 titanium implants are connected with titanium abutments (Group I, n = 10) and the other 10 titanium implants are connected with Polyether ether Ketone (PEEK) abutments (Group II, n = 10). Abutments are cyclically loaded for 550,000 cycles. Surface profilometry, scanning electron microscopy (SEM), and energy-dispersive X-ray spectrometry (EDS) are carried out for all the abutment in both Group I and Group II before and after cyclic loading. The abutment surface at the implant-abutment interface is analyzed for wear. Results: On comparison using independent “t”-test, it was found that the mean difference values of pre- and post-cyclic loading surface roughness (Ra value) of Group I (premachined titanium straight abutments) (−0.073 μm) was lower than the Group II test samples (premachined PEEK straight abutments) (−0.0004 μm), and this was found to be statistically insignificant (P = 0.272). SEM micrographs and EDS results also corroborate with the results of surface profilometry. Conclusion: The new concept in this study is Group II (PEEK abutments) are connected with titanium implants, to prove its compatibility and aesthetics. Within the limitations of the study, the surface roughness values before and after cyclic loading of two different abutment materials revealed that the wear resistance of titanium abutments is more than PEEK abutments, but the difference was found to be statistically insignificant.

1 January 2020 in Journal of Pharmacy and Bioallied Sciences
Verified
Journal Article
Open access
PDF file
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
GAGayathree Alagiriswamy
Gayathree Alagiriswamy
CKChitra Shankar Krishnan
Chitra Shankar Krishnan
SJSampath Kumar Jayakrishnakumar
Sampath Kumar Jayakrishnakumar
VMVallabh Mahadevan
Vallabh Mahadevan
NANagarasampatti Sivaprakasam Azhagarasan
Nagarasampatti Sivaprakasam Azhagarasan
Background: Zirconia being a bio-inert material needs to be surface treated to render it more bioactive and enhance its osseointegration potential. However, bioactivity studies focusing on the ability of sandblasting and ultraviolet photofunctionalization (UVP) surface treatments in inducing apatite precipitation using simulated body fluid (SBF) are lacking. Aim: The aim of the study was to comparatively evaluate the effect of two different surface treatments—sandblasting with 50 µm alumina and UVP with ultraviolet C (UVC) light on the bioactivity of zirconia. Materials and Methods: A total of 33 discs with dimensions 10 mm × 2 mm were obtained from zirconia blanks (Amann Girrbach, Koblach, Austria) and randomly divided into three groups (n = 11), namely Group I (untreated), Group II (sandblasted), and Group III (UVP). Surface characteristics of representative test samples were analyzed using X-ray diffraction (XRD), atomic force microscopy (AFM), contact angle goniometry, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX), to assess type of crystal phase of zirconia, surface roughness, wettability, surface topography, and elemental composition, respectively. SBF was prepared and calcium content in SBF (Ca-SBF) was determined using inductively coupled plasma mass spectrometry (ICP-MS). Results: Data were analyzed by one-way analysis of variance (ANOVA), post hoc Tukey honestly significant difference (HSD), and Student’s t test for statistical significance (P < 0.05, significant; P < 0.01, highly significant). Surface characteristics analyses revealed that XRD showed predominant tetragonal (t) zirconia crystal phase for all test groups. Mean surface roughness (Sa) of Group I was 41.83 nm, and it was significantly lesser than that of Group II (115.65 nm) and Group III (102.43 nm). Mean contact angles were 98.26°, 86.77°, and 68.03° for Groups I, II, and III, respectively, and these differences were highly significant. Mean pre-immersion Ca content in SBF was found to be 159 mg/L. Mean post-immersion Ca content was 70.10, 60.80, and 56.20 mg/L for Groups I, II, and III, respectively. Significant differences were found between Group I as compared to both Groups II and III. Bioactivity of Group III was marginally, but insignificantly higher with respect to Group II. Groups II and III were insignificant with respect to each other. Post-immersion XRD revealed predominant “t” phase, and SEM-EDX revealed well-formed, abundant calcium apatite layer on the treated samples as compared to that on untreated sample and an increasing Ca/P ratio from 1.15, 1.79 to 2.08, respectively from Group I to Group III. Conclusion: Within the limitations of this study, both sandblasting and UVP significantly and similarly improved bioactivity of zirconia as compared to the untreated samples, which was corroborated by the SEM-EDX results.

1 January 2010 in Indian Journal of Dental Research
Verified
Journal Article
Open access
PDF file
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
RSRaj G Singh
Raj G Singh
Background: The U-shaped maxillary major connector is considered to be the least-desirable design by many prosthodontists as it lacks rigidity, which is a primary requisite for a major connector. Aims and Objectives: Design modifications in the U-shaped palatal major connector are desired because it lacks rigidity. The study also aimed to determine the best design when a U-shaped palatal major connector is indicated for clinical use. Materials and Methods: The normal design and the design-modified models (modification 1, 2, 3, 4) were loaded at the functional cusps of the premolars and the molars with a magnitude of 200 N, 250 N and 300 N at angulations of 60 o and 90 o on both sides of the maxillary arch. Results for each loading were obtained as stress distribution colored images and numerical values were recorded. A three-dimensional finite element analysis study of the design-modified models was performed using two finite element softwares, namely PRO-E and IDEAS. Results: The least stress value of 7.86 Megapascals (MPa) at 200 N, 60 o was recorded for the double-thickness design, followed by design 1, which was 8.03 MPa. The least stress value for the palatal mucosa and ligament was provided by design modification 1 (0.5 mm-thick U-shaped connector, 9 mm anteroposteiorly, 14.6 mm laterally), which was 9.78 MPa and 2.98 MPa, respectively. Conclusion: The double-thickness group exhibited the least internal stress for the U-shaped major connector. However, it delivered the greatest stress to the palatal mucosa and the periodontal ligaments.

30 March 2022 in Journal of Dental Implant Research
Verified
Journal Article
Open access
PDF file
HRHariharan Ramakrishnan
Hariharan Ramakrishnan
MRManiamuthu Ragupathi
Maniamuthu Ragupathi
Hariharan Ramakrishnan, Maniamuthu Ragupathi. Journal of Dental Implant Research 2022;41:1-14. https://doi.org/10.54527/jdir.2022.41.1.1