This article presents a study of the applicability of fast nonlinear analytical (FNA) models in predicting the global response of Chinese traditional timber-frame building with Dou-Gon under seismic excitation. Efforts are made to overcome challenges in establishing simplified calculation models, and the corresponding dynamic equations are derived considering the mechanical behavior of sliding column root, mortise-tenon joint and Dou-Gon (bracket sets). Furthermore, nonlinear time-history analysis is conducted under different seismic excitations. Through a verification study, a good correspondence is obtained with previous shake-table test results. Seismic response analysis is also conducted to investigate the energy dissipation of column root sliding, mortise-tenon joint, and Dou-Gon. Subsequently, peak responses of column root and roof under increased values of peak ground acceleration (PGA) are also analyzed. And then, seismic isolation ability and damping characteristics of the model are discussed.
9 February 2021 in International Journal of Architectural Heritage
This paper studies the effect of performance degradation and infilled walls on the seismic fragility of a traditional Chinese timber-frame structure. The Yihe Hall was chosen as the archetype building and extended distinct element method (EDEM) models of the structures were developed using the Wallstat software. Validation of the timber frame and the whole structure were conducted, respectively. For this study, a set of 20 ground motion records were selected for the incremental dynamic analysis (IDA). Results indicate that the performance degradation of the structure significantly reduces the probability of basically intact by 18%, and increases the collapse probability by 10%. In addition, the infilled walls highly promote the probability of basically intact by 36%, and decrease the collapse probability by 7%. This study indicates that from the protection point of view, it is necessary to repair and strengthen the ancient timber structures with degraded performance to meet the reliability requirements. From the view of seismic evaluation, the coordinated seismic effect of the walls and the frame should be fully considered.
1 January 2024 in Structural Control and Health Monitoring
Timber structures are vulnerable to failure and collapse under seismic action. To improve the seismic performance of such structures, a replaceable displacement amplification rotary friction damper was proposed and designed. Six specimens were fabricated, each varying in pretension strains and employing three different composite friction materials as control parameters, followed by low cyclic loading tests. The study investigated the working mechanism, hysteresis performance, energy dissipation capacity, performance stability, and displacement amplification effect of the dampers. A finite element model was developed to analyze the hysteresis performance of the damper and evaluate the impact of various parameters on its overall effectiveness. Furthermore, a comparative analysis of the damper’s hysteresis characteristics was conducted. The theoretical calculations and finite element analysis were validated using experimental results, showing a relative error within 10%. The specimens demonstrated a notable displacement amplification capability, which increased as the intermediate connector length decreased. By reducing the length by 200 mm, the maximum damping force could be amplified by 5.5 times, while the nodal rotation values increased by 3.92 times. Additionally, for every 50 με increment in pretension strain, energy consumption increases by an average of 148%, and for each unit increase in the friction coefficient, energy consumption increases by an average of 172%.
19 March 2024 in Journal of Earthquake Engineering
1. The Chinese palace-style timber structure has a unique form of construction, characterized by mortise-tenon connections and floating column footings. Previous studies have identified various typ...
22 July 2011 in Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering
The study described in this article is the application of energy method for the prediction of flutter boundary and the effects of some parameters on aeroelastic stability in turbomachinery. The unsteady flow with multi-layer moving grid technique for blade oscillation was undergone for aerodynamic work with the blade passage being discretized using a background fixed H-grid and a body-fitted O-grid moving with the blade. Also, with the assumption of equivalent viscous damping, aerodynamic modal damping ratio was defined based on energy method. The numerical method, with mode shapes and nodal diameter numbers considered, was applied for a transonic compressor rotor stage for which measured flutter boundary on characteristic map was available. It was found that the calculated flutter boundary in the first bending blade mode agreed well with the measured one. Furthermore, it was concluded that the mode shapes and inter-blade phase angle were key parameters on aeroelasticity in turbomachinery and that the flutter instability was mainly induced by the co-action of shock wave and separated flow.