A descriptive cadaveric study incorporating a novel nerve root marking technique. To describe the displacement and strain of the lumbosacral nerve roots in the lateral recess during straight leg raise (SLR) without disrupting the foraminal ligaments. Previous studies document 2 to 8 mm of lumbosacral nerve root displacement during SLR. Prior dissection methods incorporated laminectomy and facetectomy. Lower limbs and associated nerve roots of 5 unembalmed cadavers (n = 10) were studied. Metal markers were inserted intraneurally within the lateral recess of L4, L5, and S1 with a modified spinal needle. Fluoroscopic images were digitized to evaluate displacement and strain during SLR. The lumbosacral nerve roots in the lateral recess moved less and experienced less strain during SLR than described in previously published reports. Statistically significant distal displacement occurred at hip positions greater than 60 degrees of flexion at all nerve root levels (P < 0.01). The lumbosacral nerve roots (L4, L5, S1) moved less and underwent less strain during SLR testing than previously reported and may require hip motion greater than 60 degrees to produce substantive displacement in the lateral recess. Additional research is needed to examine the effects of prepositioning during SLR.
An inferential cadaveric study. To compare the displacement and strain of the lumbosacral nerve roots during different conditions of straight leg raise (SLR) with intact foraminal ligaments. Clinicians use sensitizing movements such as dorsiflexion during neurodynamic testing, assuming that these prepositions influence the displacement or strain to the lumbosacral nerve roots. Little is known about the effect of these prepositions on neurodynamic behavior. Lower limbs and associated nerve roots of 5 unembalmed cadavers (n = 10) were used to evaluate the displacement and strain of the L4, L5, and S1 roots during 2 different SLR conditions. Fluoroscopic images of intraneural metal markers were digitized to evaluate displacement and strain during SLR with no preposition (SLR NPP) of the ankle and SLR with dorsiflexion preposition (SLR DF) of the ankle, respectively. SLR NPP produced larger distal displacement at L5 and S1, (P < 0.001) when compared with SLR DF. Displacement comparisons at L4 were nonsignificant (P = 0.051). While nonsignificant, medium to large effect sizes (0.60-0.96) suggest that SLR DF may produce more strain than the SLR NPP condition. Prepositions of the SLR test alter the displacement and possibly the strain of the lumbosacral nerve roots in the lateral recess.
27 November 2014 in Journal of Manual & Manipulative Therapy
Neural mobilization techniques are used clinically to treat neuropathic pain and dysfunction. While selected studies report efficacy of these techniques, the mechanisms of benefit are speculative. The purpose of this study was to evaluate the effects of in vitro simulated stretch/relax neural mobilization cycles on fluid dispersion within sections of unembalmed cadaveric peripheral nerve tissue. Bilateral sciatic nerve sections were harvested from six cadavers. Matched pairs of nerve sections were secured in a tissue tester and injected with a plasma/Toluidine Blue dye solution. Once the initial dye spread stabilized, the experimental nerve sections underwent 25 stretch/relaxation cycles (e.g. simulated neural mobilization) produced by a mechanical tissue tester. Post-test dye spread measurements were compared to pre-test measurements as well as control findings (no simulated mobilization). Data were analyzed using paired t-tests. Individual dye spread measurements were reliable [ICC(3,1) = 0·99]. The post-test intraneural fluid movement (dye spread) in the experimental section increased significantly with simulated neural mobilization compared to pre-test measurements (3·2±2·1 mm; P = 0·015) and control measurements (3·3±2·7 mm; P = 0·013). Repetitive simulated neural mobilization, incorporating stretch/relax cycles, of excised cadaveric peripheral nerve tissue produced an increase in intraneural fluid dispersion. Neural mobilization may alter nerve tissue environment, promoting improved function and nerve health, by dispersing tissue fluid and diminishing intraneural swelling and/or pressure.
20 October 2015 in Journal of Manual & Manipulative Therapy
Manual and physical therapists incorporate neurodynamic mobilisation (NDM) to improve function and decrease pain. Little is known about the mechanisms by which these interventions affect neural tissue. The objective of this research was to assess the effects of repetitive straight leg raise (SLR) NDM on the fluid dynamics within the fourth lumbar nerve root in unembalmed cadavers. A biomimetic solution (Toluidine Blue Stock 1% and Plasma) was injected intraneurally, deep to the epineurium, into the L4 nerve roots of seven unembalmed cadavers. The initial dye spread was allowed to stabilise and measured with a digital calliper. Once the initial longitudinal dye spread stabilised, an intervention strategy (repetitive SLR) was applied incorporating NDMs (stretch/relax cycles) at a rate of 30 repetitions per minute for 5 minutes. Post-intervention calliper measurements of the longitudinal dye spread were measured. The mean experimental posttest longitudinal dye spread measurement (1.1 ± 0.9 mm) was significantly greater (P = 0.02) than the initial stabilised pretest longitudinal dye spread measurement. Increases ranged from 0.0 to 2.6 mm and represented an average of 7.9% and up to an 18.1% increase in longitudinal dye spread. Passive NDM in the form of repetitive SLR induced a significant increase in longitudinal fluid dispersion in the L4 nerve root of human cadaveric specimen. Lower limb NDM may be beneficial in promoting nerve function by limiting or altering intraneural fluid accumulation within the nerve root, thus preventing the adverse effects of intraneural oedema.
To assess the relationship between anatomical landmarks used to locate the first rib during surface palpation. One currently cited technique suggests locating the width of the transverse processes (TPs) of the first cervical vertebrae (C1) to determine the estimated width of the first thoracic vertebrae (T1) TP, allowing for subsequent palpation of the first rib laterally to the transverse process of T1. Based on anatomical structural relationships, the authors propose an additional method of locating the first rib, lateral to T1 TP, by palpating through the trapezius muscle at the width of the mastoid process (MP). Overlying tissue of the bilateral MP, C1 TPs, and T1 TPs of 28 cadavers were removed. Measurements of the left to right spans at the following structures were collected using a digital caliper: mastoid process, C1 TP, and T1 TP. Measurements were used to determine the agreement between each anatomical structural span. The mean absolute difference (standard deviation, SD) between C1 TP span versus T1 TP span was 3.9 (±2.58) mm with an intraclass correlation coefficient (ICC) of 0.88 (95% CI = 2.9–4.9). The mean absolute difference between MP span and T1 TP span was 35.4 (±6.46) mm with an ICC of 0.71 (95% CI = 33.0–37.8). This study confirms the anatomical accuracy and feasibility of using the C1 TP span to determine the general width of the T1 TP span while palpating for the first rib just lateral to the T1 TP. Additionally, this study demonstrates that the more easily palpated mastoid process serves as an effective landmark to identify a width sufficiently lateral to the T1 TP, appropriate for first rib palpation through the trapezius muscle.