Background: Pulmonary hypertension (PH) can lead to cardiac failure, thereby significantly affecting life expectancy and quality of life. Due to inadequate disease surveillance and risk assessment, clinical challenges persist despite advances in diagnosis and treatment. We aimed to review the potential of high-sensitivity cardiac troponin (hs-cTn) as a biomarker for predicting outcomes in PH patients. Methods: A thorough examination of the PubMed and Google Scholar databases was conducted through March 2023. Studies involving adult PH patients and hsTn as a prognostic indicator of outcomes such as mortality, hospitalization, and disease progression were included, after screening their titles and abstracts. Two independent evaluators extracted data, with the quality assessed using the JBI critical appraisal tool. Results: This review uncovered eight studies that examined the prognostic value of hs-cTn in PH patients. Higher hs-cTn levels were associated with increased mortality and hospitalization rates, according to the studies. The severity of PH, cardiac dysfunction, right ventricular function, and systolic dysfunction were associated with hs-cTn. Multiple studies have demonstrated that hsTn has the potential to identify high-risk PH patients who could benefit from targeted therapies and increased clinical monitoring. Conclusions: This review suggests that hsTn may be a biomarker for PH risk stratification and prognosis. Across PH subtypes, elevated hsTn levels predict poor outcomes. However, large-scale prospective studies are needed to confirm hs-cTn’s function in diagnosing pulmonary hypertension and determine its potential value in treatment.
Background: Stroke and subclinical cerebral ischemia remain important neurological complications of transcatheter aortic valve replacement (TAVR). The Sentinel cerebral embolic protection (CEP) device is designed to capture embolic debris during TAVR, but its impact on clinical and imaging outcomes remains incompletely characterized. Methods: PubMed, Embase, and Cochrane databases were systematically searched for randomized controlled trials (RCTs) comparing Sentinel CEP versus no protection when TAVR was performed. Outcomes of interest included all stroke, disabling stroke, infarct volume by diffusion-weighted MRI in protected and unprotected areas, all-cause mortality, acute kidney injury, and major vascular complications. Risk ratios (RRs) and median differences with 95% confidence intervals (CIs) were calculated using random-effects models and trial sequential analysis (TSA) assessed evidence robustness. Results: Four RCTs including 10,986 patients were analyzed. Sentinel CEP did not significantly reduce clinical stroke (RR 0.88, 95% CI 0.69–1.12) or disabling stroke (RR 0.68, 95% CI 0.41–1.14). Pooled DW-MRI data showed a significant reduction in new ischemic lesion volume within Sentinel CEP-protected territories (difference in medians −75.7 mm3; 95% CI −130.4 to −21.0). Subgroup analyses in elderly, female, and high-surgical-risk patients revealed no benefit with Sentinel CEP. Additionally, TSA indicated that current data are underpowered for definitive conclusions. Conclusions: The Sentinel CEP device during TAVR did not significantly reduce clinical stroke but was associated with lower MRI-detected ischemic lesion volumes compared with no protection. Further adequately powered RCTs integrating clinical and imaging endpoints are needed to define its role in neuroprotection during TAVR.