Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: Background: The goal of this study was to determine the occurrence of intraoperative electromagnetic interference from monopolar electrosurgery in patients with an implantable cardioverter defibrillator undergoing surgery. A protocolized approach was used to position the dispersive electrode. Methods: This was a prospective cohort study including 144 patients with implantable cardioverter defibrillators undergoing surgery between May 2012 and September 2016 at an academic medical center. The primary objectives were to determine the occurrences of electromagnetic interference and clinically meaningful electromagnetic interference (interference that would have resulted in delivery of inappropriate antitachycardia therapy had the antitachycardia therapy not been programmed off) in noncardiac surgeries above the umbilicus, noncardiac surgeries at or below the umbilicus, and cardiac surgeries with the use of an underbody dispersive electrode. Results: The risks of electromagnetic interference and clinically meaningful electromagnetic interference were 14 of 70 (20%) and 5 of 70 (7%) in above-the-umbilicus surgery, 1 of 40 (2.5%) and 0 of 40 (0%) in below-the-umbilicus surgery, and 23 of 34 (68%) and 10 of 34 (29%) in cardiac surgery. Had conservative programming strategies intended to reduce the risk of inappropriate antitachycardia therapy been employed, the occurrence of clinically meaningful electromagnetic interference would have been 2 of 70 (2.9%) in above-the-umbilicus surgery and 3 of 34 (8.8%) in cardiac surgery. Conclusions: Despite protocolized dispersive electrode positioning, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with surgery above the umbilicus were high, supporting published recommendations to suspend antitachycardia therapy whenever monopolar electrosurgery is used above the umbilicus. For surgery below the umbilicus, these risks were negligible, implying that suspending antitachycardia therapy is likely unnecessary in these patients. For cardiac surgery, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with an underbody dispersive electrode were high. Conservative programming strategies would not have eliminated the risk of clinically meaningful electromagnetic interference in either noncardiac surgery above the umbilicus or cardiac surgery.
22 July 2017 in Journal of Interventional Cardiac Electrophysiology
Dexmedetomidine (Dex) is an attractive agent for procedural sedation due to its unique pharmacodynamic profile, specifically affording predictable sedation without concurrent respiratory depression. However, Dex has previously been reported to prevent or terminate arrhythmias. The purpose of this study was to investigate paroxysmal supraventricular tachycardia (PSVT) inducibility and homeostatic stability during electrophysiology studies (EPSs) and ablation when a standardized Dex protocol was used as the primary sedation agent. We performed a retrospective review of 163 consecutive procedures for PSVT ablation that received Dex as the primary sedative with adjunct fentanyl and midazolam boluses (DEX-FENT-MIDAZ). This cohort was compared to 163 consecutive control procedures wherein strictly fentanyl and midazolam were used for sedation. The primary outcome reviewed was PSVT inducibility assessed before ablation. Reviewed secondary outcomes included level of sedation and intraprocedure hemodynamics and oxygenation. The arrhythmia profiles of the DEX-FENT-MIDAZ and control cohorts were very similar. The overall incidence of a “negative” EPSs in which arrhythmia was not induced was 24% in the DEX-FENT-MIDAZ group and 26% in the control group (P = .7). Unintended deep sedation was significantly less with DEX-FENT-MIDAZ (4.3% vs 27%; P ≤ .0001). However, DEX-FENT-MIDAZ use was associated with a higher incidence of intraprocedure hypotension. Dex sedation during EPSs is not associated with a reduction in PSVT inducibility. The therapeutic utility of Dex during EPS arises from the predictable sedation Dex affords but is associated with an increased incidence of intraprocedure hypotension.
1 September 2017 in Circulation: Arrhythmia and Electrophysiology
Background: Implantable cardioverter-defibrillator (ICD) recipients require close follow-up that can be difficult for patients who have to travel long distances for clinic follow-up. We aimed to compare clinical outcomes between ICD patients followed-up in a telemedicine video-conferencing clinic (TMVC) and a conventional in-person clinic (CIC). We hypothesized that outcomes of patients followed in the TMVC are noninferior to the CIC. Methods and Results: This retrospective study compares time to first appropriate ICD therapy, time to first inappropriate ICD therapy, time to first shock, and overall survival in patients followed in TMVC compared with CIC between 2001 and 2016. Two hundred and eighty-seven patients were followed in the TMVC group and 236 patients in the CIC. The average age of the TMVC and CIC groups was 64.13±9.38 and 65.23±8.57 years, respectively ( P =0.164). There was no difference in the modified Seattle heart failure model score between the 2 groups (−0.12±1.0 versus −0.21±0.99; P =0.287). The Charlson comorbidity index score was higher in the CIC group compared with the TMVC group (7.0 versus 6.0; P =0.01). Mean duration of follow-up was 4.8 years. Adjusted and unadjusted tests of noninferiority found TMVC was not inferior to in-person follow-up for the prespecified outcomes. Conclusions: Video-conferencing ICD follow-up for patients in areas where electrophysiology subspecialty care is not available leads to outcomes that are noninferior to CIC follow-up.
21 May 2019 in Journal of Cardiovascular Electrophysiology