Andrew Bazyk

Mr. Andrew Bazyk

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ABAndrew Bazyk
Andrew Bazyk
RKRyan D Kaya
Ryan D Kaya
CWColin Waltz
Colin Waltz
EZEric Zimmerman
Eric Zimmerman
JJJoshua D. Johnston
Joshua D. Johnston
JAJay Lance Alberts
Jay Lance Alberts
Background/Objectives: Technological approaches for the objective, quantitative assessment of motor functions have the potential to improve the medical management of people with Parkinson’s disease (PwPD), offering more precise, data-driven insights to enhance diagnosis, monitoring, and treatment. Markerless motion capture (MMC) is a promising approach for the integration of biomechanical analysis into clinical practice. The aims of this project were to evaluate a commercially available MMC system, develop and validate a custom MMC data processing algorithm, and evaluate the effectiveness of the algorithm in discriminating fine motor performance between PwPD and healthy controls (HCs). Methods: A total of 58 PwPD and 25 HCs completed finger-tapping assessments, administered and recorded by a self-worn augmented reality headset. Fine motor performance was evaluated using the headset’s built-in hand tracking software (Native-MMC) and a custom algorithm (CART-MMC). Outcomes from each were compared against a gold-standard motion capture system (Traditional-MC) to determine the equivalence. Known-group validity was evaluated using CART-MMC. Results: A total of 82 trials were analyzed for equivalence against the Traditional-MC, and 152 trials were analyzed for known-group validity. The CART-MMC outcomes were statistically equivalent to Traditional-MC (within 5%) for tap count, frequency, amplitude, and opening velocity metrics. The Native-MMC did not meet equivalence with the Traditional-MC, deviating by an average of 24% across all outcomes. The CART-MMC captured significant differences between PwPD and HCs for tapping amplitude, amplitude variability, frequency variability, finger opening and closing velocities, and their respective variabilities, and normalized path length. Conclusions: The biomechanical data gathered using a commercially available augmented reality device and analyzed via a custom algorithm accurately characterize fine motor performance in PwPD.

28 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MKMandy Miller Koop
Mandy Miller Koop
ARAnson Rosenfeldt
Anson Rosenfeldt
KSKathryn Scelina
Kathryn Scelina
LSLogan Scelina
Logan Scelina
CWColin Waltz
Colin Waltz
JAJay Lance Alberts
Jay Lance Alberts
Freezing of gait (FOG) is a disabling symptom associated with Parkinson’s disease (PD). Its understanding and effective treatment is compromised due to the difficulty in reliably triggering FOG in clinical and laboratory environments. The Cleveland Clinic-Virtual Home Environment (CC-VHE) platform was developed to address the challenges of eliciting FOG by combining an omnidirectional treadmill with immersive virtual reality (VR) environments to induce FOG under physical, emotional, and cognitive triggers. Recent developments in deep brain stimulation devices that sense neural signals from the subthalamic nucleus in real time offer the potential to understand the underlying neural mechanism(s) of FOG. This manuscript presents the coupling of the CC-VHE technology, VR paradigms, and the experimental and analytical methods for recording and analyzing synchronous cortical, subcortical, and kinematic data as an approach to begin to understand the nuanced neural pathology associated with FOG. To evaluate the utility and feasibility of coupling VR and neural sensing technology, initial data from one participant are included.

13 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ABAndrew Bazyk
Andrew Bazyk
CWColin Waltz
Colin Waltz
RKRyan D Kaya
Ryan D Kaya
EZEric Zimmerman
Eric Zimmerman
JJJoshua D. Johnston
Joshua D. Johnston
JAJay Lance Alberts
Jay Lance Alberts
Subjective, imprecise evaluation of lower extremity function hinders the effective treatment of gait impairments in Parkinson’s disease (PD). Markerless motion capture (MMC) offers opportunities for integrating objective biomechanical outcomes into clinical practice. However, validation of MMC biomechanical outcomes is necessary for clinical adoption of MMC technologies. This project evaluated the criterion validity of a custom MMC algorithm (CART-MMC) against gold-standard 3D motion capture (Traditional-MC) and its known-groups validity in differentiating PD from healthy controls (HC). Sixty-two individuals with PD and 29 HCs completed a stepping in place paradigm. The trials were recorded by an augmented reality headset with embedded RGB and depth cameras. The CART-MMC algorithm was used to reconstruct a 3D pose model and compute biomechanical measures of lower extremity performance. CART-MMC outcomes were statistically equivalent, within 5% of Traditional-MC, for measures of step count, cadence, duration, height, height asymmetry, and normalized path length. CART-MMC captured significant between-group differences in step height, height variability, height asymmetry, duration variability, and normalized path length. In conclusion, CART-MMC provides valid biomechanical outcomes that characterize important domains of PD lower extremity function. Validated biomechanical evaluation tools present opportunities for tracking subtle changes in disease progression, informing targeted therapy, and monitoring treatment efficacy.

15 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MKMandy Miller Koop
Mandy Miller Koop
CWColin Waltz
Colin Waltz
ABAndrew Bazyk
Andrew Bazyk
BLBrittany Lapin
Brittany Lapin
Yong LiYong Li
Yong Li
JAJay Lance Alberts
Jay Lance Alberts
Many people with Parkinson’s disease (PwPD) lack optimal care due to limited access to neurologists and a reliance on subjective rating scales for treatment decisions. The Ceraxis Insight platform was designed to provide quantitative measures of the cardinal motor symptoms of Parkinson’s disease (PD) through self-administered assessments performed using a tablet paired with a sensor-embedded stylus. The aim of this study was to assess the validity of the Ceraxis Insight outcome metrics against clinical gold-standard measures of PD motor symptoms. Nineteen PwPD completed a clinical examination and the nine Ceraxis Insight assessment modules. Quantitative performance metrics were calculated from the platform’s IMU, force transducer, and touchscreen inputs. Mixed-effect models and correlation analyses determined that multiple quantitative metrics from the Ceraxis Insight modules significantly predicted (p < 0.05) and were significantly correlated (correlation coefficients > 0.70) with the MDS-UPDRS III total score, bradykinesia, tremor, rigidity, and postural instability and gait difficulty sub-scores. Logistic regression models determined that multiple Ceraxis Insight metrics discriminated between ON- and OFF-deep brain stimulation (DBS) conditions, with Area Under the Receiver Operating Characteristic Curve (AUC) values exceeding 0.70. The Ceraxis Insight platform provides a validated, objective assessment of PD motor symptoms that may be performed within clinical or remote settings for data-driven evaluation and treatment.

1 January 2026 in Parkinson's Disease
Verified
Journal Article
Open access
PDF file
RKRyan D Kaya
Ryan D Kaya
ABAndrew Bazyk
Andrew Bazyk
CWColin Waltz
Colin Waltz
EZEric Zimmerman
Eric Zimmerman
JJJoshua D. Johnston
Joshua D. Johnston
JAJay Lance Alberts
Jay Lance Alberts
Background/Objectives: Postural instability compromises balance, contributing to annual fall rates of 45%–68% in Parkinson’s disease (PD). A fundamental gap in clinical evaluation and treatment of postural instability is the use of insufficiently challenging postural control tests and reliance on subjective scoring. Traditional 3D motion capture (Traditional‐MC), while precise and objective, is not feasible for clinical utilization. Markerless motion capture (MMC) is a viable candidate for quantifying postural control, feasible with embedded cameras of augmented reality (AR) headsets. This project aimed to assess MMC accuracy in quantifying postural control and to compare PD patients and healthy controls (HCs) to develop a loss‐of‐balance (LOB) prediction model. Methods: Video data were acquired by a clinician wearing a Microsoft HoloLens 2 AR headset as participants completed three progressively challenging postural control stances. Depth and red–green–blue camera data were analyzed with our custom‐built human pose estimation software (CART‐MMC). Criterion validity between Traditional‐MC and CART‐MMC was completed on outcomes, 95% ellipsoid sway area (Sway area) and 95% mediolateral and anteroposterior (ML and AP) ranges in 54 (HC = 28, PD = 26) participants. Group differences were assessed, and survival analysis was conducted to quantify no LOB probabilities in 31 HCs and 68 PD patients. A relaxed LASSO model was used to predict LOB in the PD group from CART‐MMC data. Results: Sway area and ML range from CART‐MMC were equivalent to Traditional‐MC. Furthermore, ML range from CART‐MMC differentiated PD patients from HCs in the stance that had the highest completion rate. As postural task difficulty increased, fewer PD patients were able to complete compared to HCs, resulting in lower survival probabilities of the PD group in Tandem‐Firm‐EO and FT‐Foam‐EC stances. In the least challenging stance, ML range predicted the occurrence of LOB in the more challenging stance (LOO‐CV AUC = 0.78). Conclusions: CART‐MMC is a valid method of obtaining objective postural control outcomes, which can detect latent postural control deficits and demonstrates a scalable, objective clinical and remote monitoring approach for predicting falls.