Tommy Sugiarto

Mr. Tommy Sugiarto

Industrial Technology Research Institute, Taiwan
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
WHWei-Chun Hsu
Wei-Chun Hsu
TSTommy Sugiarto
Tommy Sugiarto
YLYi-Jia Lin
Yi-Jia Lin
FYFu-Chi Yang
Fu-Chi Yang
ZLZheng-Yi Lin
Zheng-Yi Lin
KCKuan-Nien Chou
Kuan-Nien Chou
The aim of this study was to conduct a comprehensive analysis of the placement of multiple wearable sensors for the purpose of analyzing and classifying the gaits of patients with neurological disorders. Seven inertial measurement unit (IMU) sensors were placed at seven locations: the lower back (L5) and both sides of the thigh, distal tibia (shank), and foot. The 20 subjects selected to participate in this study were separated into two groups: stroke patients (11) and patients with neurological disorders other than stroke (brain concussion, spinal injury, or brain hemorrhage) (9). The temporal parameters of gait were calculated using a wearable device, and various features and sensor configurations were examined to establish the ideal accuracy for classifying different groups. A comparison of the various methods and features for classifying the three groups revealed that a combination of time domain and gait temporal feature-based classification with the Multilayer Perceptron (MLP) algorithm outperformed the other methods of feature-based classification. The classification results of different sensor placements revealed that the sensor placed on the shank achieved higher accuracy than the other sensor placements (L5, foot, and thigh). The placement-based classification of the shank sensor achieved 89.13% testing accuracy with the Decision Tree (DT) classifier algorithm. The results of this study indicate that the wearable IMU device is capable of differentiating between the gait patterns of healthy patients, patients with stroke, and patients with other neurological disorders. Moreover, the most favorable results were reported for the classification that used the combination of time domain and gait temporal features as the model input and the shank location for sensor placement.

25 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
WHWei-Chun Hsu
Wei-Chun Hsu
TSTommy Sugiarto
Tommy Sugiarto
JCJun Wen Chen
Jun Wen Chen
YLYi-Jia Lin
Yi-Jia Lin
This study aimed to find the correlation between conventional Arch Index (AI) measurements and our prototype of a simplified insole-based plantar pressure measurement system and to find out the effective plantar pressure sensor position. Twenty-one subjects participated in this study, which was divided into two groups: 10 subjects with flatfoot and 11 subjects with normal foot. Five force sensitive resistance sensors were used on this prototype using Arduino as the data acquisition device. Two types of trials, namely static and dynamic, were conducted to validate our system against the ink-type AI measurement as a golden standard. The results showed that in the static trial, there was a high linear correlation with the medial arch sensor configuration, while in the dynamic trial, there was a high linear correlation in the medial arch sensor configuration and sensor 5 configuration. This study showed that both static and dynamic tests using the self-developed device could effectively determine most of the flatfoot subjects and suggests that in the future, it can be applied in clinical applications because of its advantages when compared to the expensive-high tech graphic input board and conventional tools, like ink-type based measurements.

18 March 2021 in IEEE Access
Verified
Journal Article
Open access
TSTommy Sugiarto
Tommy Sugiarto
CHChun-Lung Hsu
Chun-Lung Hsu
CSChi-Tien Sun
Chi-Tien Sun
WHWei-Chun Hsu
Wei-Chun Hsu
SYShu-Hao Ye
Shu-Hao Ye
KLKuan-Ting Lu
Kuan-Ting Lu
Head orientation prediction is one of the solutions to reduce end-to-end latency on Virtual Reality (VR) systems and is important since it can alleviate negative effects like motion sickness. This study compared head orientation prediction models from two different electromyography (EMG) systems: surface EMG (sEMG) and High-Density EMG (HD-EMG). The deep learning method was used to train the prediction model, and the results showed that the model with input from the pre-processed sEMG + IMU sensor outperformed the model with input from the HD-EMG + IMU sensor. However, the decreasing performance from HD-EMG was compensated by its comfort and the ease of use of its electrode. This tradeoff between performance and usability with sEMG compared to HD-EMG should be a consideration for users who want to choose between performance and ease of use for head orientation prediction purposes. Comparison with state-of-the-art head prediction methods proved that the sEMG-based model offers better performance in predictions when users change their head directions, which was quantified by calculating the dt peaks. In other words, our sEMG-based prediction model is suitable for VR applications, which require the user to perform high-intensity or abrupt movements, such as in FPS games or exercise/sports games.

8 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WHWei-Chun Hsu
Wei-Chun Hsu
TSTommy Sugiarto
Tommy Sugiarto
YLyingyi liao
yingyi liao
YLYi-Jia Lin
Yi-Jia Lin
FYFu-Chi Yang
Fu-Chi Yang
KCKuanNien Chou
KuanNien Chou
This study classified the gait patterns of normal and stroke participants by using time- and frequency-domain features obtained from data provided by an inertial measurement unit sensor placed on the subject’s lower back (L5). Twenty-three participants were included and divided into two groups: healthy group (young and older adults) and stroke group. Time- and frequency-domain features from an accelerometer were extracted, and a feature selection method comprising statistical analysis and signal-to-noise ratio (SNR) calculation was used to reduce the number of features. The features were then used to train four Support Vector Machine (SVM) kernels, and the results were subsequently compared. The quadratic SVM kernel had the highest accuracy (93.46%), as evaluated through cross-validation. Moreover, when different datasets were used on model testing, both the quadratic and cubic kernels showed the highest accuracy (96.55%). These results demonstrated the effectiveness of this study’s classification method in distinguishing between normal and stroke gait patterns, with only using a single sensor placed on the L5.

1 December 2017
Verified
Conference Paper
Closed access
TSTommy Sugiarto
Tommy Sugiarto
YLYi-Jia Lin
Yi-Jia Lin
CCChao-Chin Chang
Chao-Chin Chang
WHWei-Chun Hsu
Wei-Chun Hsu
This study aimed to validate the application of an inertial measurement unit (IMU) sensor for calculating the spatiotemporal parameters of gait in healthy young and older adults. Six healthy young adults and four older adults participated in this study; each wore an IMU sensor on the fifth lumbar vertebra (L5) while the sensor was synchronized with a three-dimensional motion capture system. Nineteen gait parameters, including duration, variability, and asymmetry, were calculated from initial contact and final contact event times. Results showed that the gait parameters calculated from the wearable device system were reliable and had a small absolute mean difference from the parameters calculated using a motion capture system, and the highest absolute mean difference was only 0.01 s in the stance and swing phases among the young subjects.

4 December 2019 in IEEE Consumer Electronics Magazine
Verified
Journal Article
Closed access
WHWei-Chun Hsu
Wei-Chun Hsu
TSTommy Sugiarto
Tommy Sugiarto
Jia-Lin WuJia-Lin Wu
Jia-Lin Wu
YLYi-Jia Lin
Yi-Jia Lin
LLLi-Fong Lin
Li-Fong Lin
YLYung-Hsiang Lee
Yung-Hsiang Lee
The vastus medialis oblique (VMO) and vastus lateralis (VL) muscles at the knee joint play important roles for coordination, stability, and posture control. However, no currently available device records muscle activity while simultaneously warning users regarding abnormal muscle activity. This study used a commercialized electromyography sensors placed on the VL and VMO to monitor muscle activity while triggering warnings and vibration feedback to the muscles when an undesired ratio of VL/VMO muscular activation level set by current study was detected. The system was able to trigger alarms when the subject performed moderate-intensity activity and avoid triggering during low-intensity activity. Further research is needed of high-intensity exercises, such as running or weightlifting, to determine the effects of increased muscle activity on the judgment of the undesired ratio of VL/VMO muscular activation level using the device reported in the current study.