Toshifumi Nogawa

Dr. Toshifumi Nogawa

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
TNToshifumi Nogawa
Toshifumi Nogawa
MSMasayasu Saito
Masayasu Saito
NMNaomichi Murashima
Naomichi Murashima
YTYoshiyuki Takayama
Yoshiyuki Takayama
AYAtsuro Yokoyama
Atsuro Yokoyama
Background: Implant-supported removable partial dentures (ISRPDs) are an effective treatment for partially edentulous patients. ISRPDs improve patients’ satisfaction and oral function to a greater extent than RPDs by improving denture stability and enhancing support. However, the effect of a type of direct retainer on displacement of the abutment teeth and dentures in ISRPDs remains unclear. Therefore, we made a resin mandibular model of unilateral mandibular distal-extension partial edentulism for mechanical simulation and compared the dynamic behavior of the abutment teeth and the denture base among different tooth-borne retainers with various rigidities for RPDs and ISRPDs. Methods: A resin mandibular model for mechanical simulation that had unilateral mandibular distal-extension edentulism and was missing the first molar, second molar, first premolar, and second premolar, and a denture fabricated from the patient’s computed tomography images were used. Three types of direct retainers with different connecting rigidities were evaluated. The vertical displacement of the denture base and buccal and lingual sides and the mesial displacement of the abutment teeth were measured. Results: Regardless of the rigidity of the direct retainers and loading positions, the displacement of the denture bases in the ISRPDs was significantly smaller than that in the RPDs (P < 0.001). There was no significant difference in vertical displacement of the denture bases among direct retainers with various connecting rigidities in the ISRPDs. Conversely, horizontal displacement of the abutment teeth in both the RPDs and ISRPDs tended to be larger with the cone crown telescope, which has high rigidity, than with the cast cingulum rest and wire clasp, which have much lower rigidities. Conclusion: Our results suggested that cast cingulum rest and wire clasps as direct retainers are appropriate ISRPDs to minimize denture movement and suppress displacement of the remaining teeth in patients with unilateral mandibular distal-extension partial edentulism.

1 December 2022 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
TNToshifumi Nogawa
Toshifumi Nogawa
YTYoshiyuki Takayama
Yoshiyuki Takayama
MIMakoto Ishikawa
Makoto Ishikawa
AYAtsuro Yokoyama
Atsuro Yokoyama
Background: Implant-supported removable partial dentures (ISRPDs) provide effective prosthodontic treatment for partially edentulous patients. ISRPDs offer greater patient satisfaction and better oral function compared with removable partial dentures (RPDs) by enhancing denture stability and support. However, few clinical studies have focused on RPD design in patients with mandibular Kennedy Class II edentulism. The aim of this case reports was to investigate the oral function, oral health-related quality of life, and satisfaction of four patients with unilateral distal-extension mandibular RPDs with the same design which were replaced with ISRPDs. In addition, we investigated how each patient’s evaluation varied with the change from RPD to ISRPD. Case presentation: Four patients had unilateral distal-extension mandibular edentulism and were missing the first and second molars and the first and second premolars. They received one implant (4.0 mm in diameter, 8.0 mm in length; IAT EXA PLUS Bone level; Nippon Piston Ring Co. Ltd, Saitama, Japan) at the position equivalent to the first molar in the edentulous residual ridge perpendicular to the occlusal plane. Implant position was determined by surgical guide plate. RPDs were fabricated after the residual mucosal membrane had healed. The basic design of the RPD was as follows: a cobalt–chromium alloy cast metal framework denture with a lingual bar as the major connector, a double Akers clasp on the molars and an auxiliary retainer on the premolar as indirect retainers, and a wrought wire clasp and a cast cingulum rest (combination clasp) as direct retainers. Masticatory performance, occlusal force, oral health-related quality of life, and satisfaction were estimated at baseline, and at time points after insertion of the RPD and after insertion of the adapted ISRPD. Each evaluation item showed a tendency for improvement on insertion of the new RPD. Masticatory performance and satisfaction tended to be better after insertion of the ISRPD than after insertion of the RPD. Conclusion: Our findings suggest that ISRPDs provided better patient satisfaction and masticatory performance than RPDs in patients with mandibular Kennedy Class II edentulism. Trial registration UMIN Clinical Trials Registry and Japan Registry of Clinical Trials, UMIN000025283 and jRCTs012180003. Registered 19 February 2016 and 17 December 2018, https://www.umin.ac.jp/ and https://jrct.niph.go.jp/

11 November 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
NMNaomichi Murashima
Naomichi Murashima
YTYoshiyuki Takayama
Yoshiyuki Takayama
TNToshifumi Nogawa
Toshifumi Nogawa
AYAsturo Yokoyama
Asturo Yokoyama
KSKiwamu Sakaguchi
Kiwamu Sakaguchi
Background: In recent years, implant-assisted removable partial dentures (IARPDs) have been used clinically. However, the extent to which additional implants reduce the burden of supporting tissues is unclear. The aim of this study was therefore to investigate the influence of implanted IARPDs on stress sharing among supporting tissues, using finite element (FE) analysis. Methods: FE models were constructed based on the computed tomography (CT) of a patient with a unilateral defect of the mandibular premolars and molars and the surface data of an RPD with cuspids as abutments, designed using computer-aided design software. A titanium implant was placed in the area equivalent to the first premolar, second premolar, or first molar (IARPD4, IARPD5, and IARPD6, respectively). FE analysis was performed for laterally symmetrical models, i.e., bilateral distal free-end IARPDs. A vertical load of 200 N was applied to the central fossa of the artificial premolars or molars (L4, L5, or L6). Results: Equivalent stress in the alveolar mucosa and vertical displacement of the denture was smaller, with IARPDs under L5 and L6 loads, compared to RPDs. However, abutment teeth were displaced upward under an L6 load in the IARPD5 model. Conclusions: Within the limitations of this study, the area corresponding to the first molar was recommended as the location for an implant under the denture base of bilateral distal free-end IARPDs. Implants located in the area corresponding to the second premolar may apply non-physiological extrusion force on abutment teeth under the load on the artificial second molar.

12 January 2022 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
RYRyo Yamada
Ryo Yamada
TNToshifumi Nogawa
Toshifumi Nogawa
YTYoshiyuki Takayama
Yoshiyuki Takayama
KIKai Iwata
Kai Iwata
MSMasayasu Saito
Masayasu Saito
AYAtsuro Yokoyama
Atsuro Yokoyama

12 January 2023 in International Dental Journal
Verified
Journal Article
Open access
DTDairo Takahashi
Dairo Takahashi
TKTakashi Kanehira
Takashi Kanehira
JTJunji Takehara
Junji Takehara
KNKimiya Nakamura
Kimiya Nakamura
RMRyo Miyake
Ryo Miyake
Manabu MoritaManabu Morita
Manabu Morita
The purposes of this study were to analyse trends in primary tooth emergence patterns and to identify physical factors potentially associated with them. The participants were 27,454 infants who underwent routine 18-month-old health examinations in Ebetsu City, Japan, between 1980 and 2012. This study was conducted using data from infants' 18-month-old health examinations over a 33-year period. The mean number of emerged primary teeth was analysed by sex using a general linear model. For logistic regression analysis, the proportion of infants with 16 emerged teeth or more at 18 months old was used as a dependent variable. Examination year; birth order; birth weight; weight, height, and chest girth at 18 months old; number of fused teeth; and mother's age were used as independent variables. The mean number of emerged primary teeth decreased over the 33-year period. Birth weight and weight and height at 18 months old decreased, and the proportion of low-birth-weight (<2500 g) infants increased over the 33-year period. On general linear model analysis, the yearly change in the mean number of emerged primary teeth was -0.0188 for boys and -0.0181 for girls. Birth weight and weight and height at 18 months old were significantly associated with the presence of 16 emerged primary teeth or more, according to the logistic regression analysis. The results demonstrated that, over the 33-year period examined, the mean number of emerged primary teeth decreased and birth weight and weight and height at 18 months old were associated with the pattern of tooth emergence.

16 February 2022 in medRxiv
Verified
Preprint
Open access
PDF file
MTMoyoko Tomiyasu
Moyoko Tomiyasu
YSYasuka Sahara
Yasuka Sahara
EMEtsuko Mitsui
Etsuko Mitsui
HTHiroki Tsuchiya
Hiroki Tsuchiya
TMTakamasa Maeda
Takamasa Maeda
TOTakayuki Obata
Takayuki Obata
Background: Visualization of aqueous humor flow in the human eye is difficult because gadolinium, a magnetic resonance imaging (MRI) contrast agent, does not readily cross the blood-retinal and blood-aqueous barriers of capillaries that supply water to the eye. The proton ( 1 H) of oxygen-17 water (H 2 17 O) has a very short transverse relaxation time (T 2 ), and the T2-weighted (T2W) 1 H-MRI signal intensity of a region with H 2 17 O is lower than that with only H 2 16 O. Purpose: To observe the distribution of H 2 17 O in the human eye, and the flow into and out of the anterior chamber of H 2 17 O, using dynamic T2W 1 H-MRI. Materials and Methods: Seven ophthalmologically normal adult volunteers under 40 years old participated in this study. During dynamic imaging, the subject self-administered 10 mol% H 2 17 O saline (0.92–1.37 mL) to their right eye for 1 min. Time-series images were created by subtracting the image before the eye drops from each of the images obtained after the eye drops. The “normalized signal intensity of the right anterior chamber” (rAC) in each image was obtained by dividing the signal intensity of the right anterior chamber region-of-interest by that of the left. Changes in transverse relaxation rate and H 2 17 O concentration ( P O 17 ) were calculated from the rAC. The inflow and outflow constants of H 2 17 O in the right anterior chamber were also determined. Results: Decreased signal intensity after the H 2 17 O eye drops was observed in the anterior and posterior chambers, but not in the vitreous body. The rAC signal intensity decreased after the eye drops, and then recovered to close to rAC(0) at 40 min. The inflow and outflow constants were 0.53 ± 0.19 and 0.055 ± 0.019 min -1 , respectively, and the peak value of P O 17 was 0.19 ± 0.04% (mean ± SD). Conclusion: H 2 17 O saline eye drops distributed in the human anterior and posterior chambers. Further, the eye drops smoothly flowed into, and slowly out of, the anterior chamber. Summary: O-17 water dropped into human eyes as a T2-weighted MRI contrast agent was distributed in the anterior and posterior chambers, with smooth flow into, and slow outflow from, the anterior chamber. Key findings: In seven healthy volunteers, dynamic T2-weighted 1 H-MRI showed that the signal intensity in the anterior chamber decreased smoothly after H 2 17 O eye drops and then slowly recovered, reaching a value close to that observed before the eye drops, after 40 minutes, with inflow and outflow constants of H 2 17 O of 0.53 ± 0.19 min -1 and 0.055 ± 0.019 min -1 , respectively. The signal changes were limited to the anterior and posterior chambers and were not observed in the vitreous body.