Farzan Ghalichi

Prof. Farzan Ghalichi


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2017 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
MSMinou Kouh Soltani
Minou Kouh Soltani
SKSohrab Khanmohammadi
Sohrab Khanmohammadi
FGFarzan Ghalichi
Farzan Ghalichi
Farrokh Janabi-SharifiFarrokh Janabi-Sharifi
Farrokh Janabi-Sharifi

4 July 2020 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
MAMehran Ashrafi
Mehran Ashrafi
JGJosé Eduardo Gubaua
José Eduardo Gubaua
JPJucélio Tomás Pereira
Jucélio Tomás Pereira
FGFarzan Ghalichi
Farzan Ghalichi
Manuel DoblaréManuel Doblaré
Manuel Doblaré

1 March 2016 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
PDF file
RTReza Tabe
Reza Tabe
FGFarzan Ghalichi
Farzan Ghalichi
SHSiamak Hossainpour
Siamak Hossainpour
KGKamran Ghasemzadeh
Kamran Ghasemzadeh
Laminar, turbulent, transitional, or combine areas of all three types of viscous flow can occur downstream of a stenosis depending upon the Reynolds number and constriction shape parameter. Neither laminar flow solver nor turbulent models for instance the k – ω ( k –omega), k – ε ( k –epsilon), RANS or LES are opportune for this type of flow. In the present study attention has been focused vigorously on the effect of the constriction in the flow field with a unique way. It means that the laminar solver was employed from entry up to the beginning of the turbulent shear flow. The turbulent model ( k – ω SST Transitional Flows ) was utilized from starting of turbulence to relaminarization zone while the laminar model was applied again with onset of the relaminarization district. Stenotic flows, with 50 and 75% cross-sectional area, were simulated at Reynolds numbers range from 500 to 2000 employing FLUENT (v6.3.17). The flow was considered to be steady, axisymmetric, and incompressible. Achieving results were reported as axial velocity, disturbance velocity, wall shear stress and the outcomes were compared with previously experimental and CFD computations. The analogy of axial velocity profiles shows that they are in acceptable compliance with the empirical data. As well as disturbance velocity and wall shear stresses anticipated by this new approach, part by part simulation, are reasonably valid with the acceptable experimental studies.

5 November 2019 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MAMehran Ashrafi
Mehran Ashrafi
FGFarzan Ghalichi
Farzan Ghalichi
BMBehnam Mirzakouchaki
Behnam Mirzakouchaki
AAAlberto Arruga
Alberto Arruga
MDManuel Doblare
Manuel Doblare

28 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MSMinou Kouh Soltani
Minou Kouh Soltani
SKSohrab Khanmohammadi
Sohrab Khanmohammadi
FGFarzan Ghalichi
Farzan Ghalichi
This paper presents an efficient shape-based three-axial force and stiffness estimator for active catheters commonly implemented in cardiac ablation. The force-sensing capability provides important feedback for catheterization procedures including real-time control and catheter steering in autonomous navigation systems. The proposed platform is based on the introduced accurate and computationally efficient Cosserat rod model for tendon-driven catheters. The proposed nonlinear Kalman filter formulation for contact force estimation along with the developed catheter model provides a real-time force observer robust to nonlinearities and noise covariance uncertainties. Furthermore, the proposed platform enables stiffness estimation in addition to tip contact force sensing in different operational circumstances. The approach incorporates pose measurements which can be achieved using currently developed pose-sensing systems or imaging techniques. The method makes the approach compatible with the range of forces applied in clinical applications. The simulation and experimental results verify the viability of the introduced force and stiffness-sensing technique.

21 March 2018 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
PDF file
MJMahsa Jahed
Mahsa Jahed
FGFarzan Ghalichi
Farzan Ghalichi
MFMehdi Farhoudi
Mehdi Farhoudi
Background: Circle of Willis (COW) is a network of cerebral artery which continually supplies the brain with blood. Any disturbance in this supply will result in trauma or even death. One of these damages is known as brain Aneurysm. Clinical methods