Corneal foreign bodies are reported to be the second most common type of ocular injury. Anterior segment optical coherence tomography (AS-OCT) is a valuable tool for the early diagnosis and monitoring the progress of treatment in cases of ocular trauma. Herein we aimed to report on a patient with an intra-corneal foreign body and the role of AS-OCT in management. A 34-year-old male presented with foreign body sensation in his left eye. Slit-lamp biomicroscopic examination revealed a peripherally located intrastromally embedded foreign body with a free anterior edge extending outwards from the cornea. It was not possible to visualize the foreign body’s entire route through the cornea because of localized corneal edema. AS-OCT showed shadowing of the corneal layers corresponding to the location of the corneal foreign body. A hyper-reflective lesion was observed close to the inside edge of the foreign body in the cornea, indicating that the foreign body had not completely penetrated the cornea. The foreign body was removed via the external route, as it had not completely penetrated the cornea. During the postoperative period the patient was asymptomatic, although the left eye’s cornea healed with scar tissue. AS-OCT facilitates non-invasive rapid imaging of ocular tissue at va rious depths, thereby providing accurate assessment of foreign body characteristics.The location of an intracorneal foreign body and the status of the surrounding ocular structure dictate the optimal surgical technique to be employed. AS-OCT in the present case facilitated localization and determination of the size of a corneal foreign body. In addition, AS-OCT findings assisted in selection of the appropriate surgical intervention.
Purpose: To determine the effect of aging on corneal biomechanical parameters measured via ocular response analyzer in a homogenous healthy Caucasian population. Methods: A total of 2039 Caucasian adults were consecutively recruited and divided into seven groups according to decades of age. The difference in mean corneal hysteresis (CH), mean corneal resistance factor (CRF), mean Goldmann-correlated intraocular pressure (IOPg), and mean corneal-compensated IOP (IOPcc) between decades of age were investigated. The strength of the correlations between corneal biomechanical parameters, and between each biomechanical parameter and age were evaluated. The effect of age on each corneal biomechanical parameter was analyzed. Results: Mean age of the participants (1173 female and 866 male) was 43.30 ± 14.64 years. Mean CH, CRF, IOPcc, and IOPg were 11.49 ± 1.89 mmHg, 11.40 ± 2.30 mmHg, 15.01 ± 3.11 mmHg, and 15.72 ± 3.80 mmHg, respectively. There were significant differences in mean CH, CRF, IOPcc, and IOPg between groups (p < 0.001 for all parameters). There was a significant negative correlation between age and CH (r = –0.067 and p = 0.003), and a significant negative correlation between age and CRF (r = –0.053 and p = 0.017). There was a significant positive correlation between age and IOPg (r = 0.25 and p < 0.001), and between age and IOPcc (r = 0.20 and p < 0.001). Linear regression analysis showed that for every 1-year increase CH decreased 0.011 mmHg, CRF decreased 0.004 mmHg, IOPcc increased 0.053 mmHg, and IOPg increased 0.047 mmHg. Conclusions: Aging can cause significant changes in corneal biomechanical parameters. Corneal biomechanical parameters were correlated with each other, and each was correlated with aging.
31 January 2018 in Advances in Clinical and Experimental Medicine
Background. The effect of hemodialysis (HD) on intraocular pressure (IOP) has been investigated before, but there is a lack of consensus. Clinicians dealing with renal failure patients are interested in the potential negative effects of HD on IOP and the course of glaucoma. Objectives. The aim of this study was to investigate the effects of HD on IOP in patients with end-stage renal disease. Material and methods. This prospective study included 106 patients who were receiving outpatient hemodialysis. Patient history of systemic and ophthalmologic conditions was recorded. Serum osmolality (mOsm), blood urea nitrogen (BUN), blood glucose (BG), bicarbonate (BC), and hematocrit (Hct) levels at the start of HD (pre-HD), at the end of HD (end-HD), and 30 min after HD (post-HD) were measured. Systolic and diastolic blood pressures (SBP and DBP) and IOP were measured at pre-HD, 1-hour intervals during HD, end-HD, and post-HD. Results. A significant decrease in mOsm and BUN and a significant increase in BG, BC, and Hct levels were observed at end-HD (p < 0.05). Mean IOP was 16.71 +/- 2.51 mm Hg at pre-HD, 15.52 +/- 3.18 mm Hg at end-HD, and 15.23 +/- 2.73 mm Hg at post-HD (p = 0.001; F = 4.439). Post-HD SBP and DBP were significantly lower than at pre-HD (p < 0.001). There was a positive correlation between the change in IOP and the change in mOsm and the change in BUN at end-HD (r = 0.315, p = 0.004; and r = 0.279, p = 0.012, respectively). Conclusions. IOP decreased significantly during HD in this study. Additional research on the effects of the change in blood parameters and ocular perfusion pressure on IOP and optic nerve perfusion during HD is recommended.
1 September 2018 in Eye & Contact Lens: Science & Clinical Practice
Objectives: To determine the effects of estrogen and progesterone on corneal thickness, curvature, and biomechanics in healthy corneas according to hormonal status. Methods: The study included four groups of females: group A (menstruating, not pregnant, not lactating, and not menopausal; n=100), group B (pregnant; n=50), group C (lactating; n=50), and group D (menopausal; n=50). Group A was subdivided according to age, as subgroup A15–25 (age 15–25 years) and subgroup A>25 (age >25 years). Blood estradiol and progesterone levels were measured in each participant. All the participants underwent a full ophthalmologic examination, including corneal thickness and corneal topography measurement, and evaluation of corneal biomechanical properties. Results: The corneal resistance factor and anterior corneal flat keratometry values were significantly higher in group D (P=0.040 and P=0.026, respectively) than in the other three groups. Posterior corneal steep keratometry values were significantly higher in subgroup A>25 during the preovulatory phase than ovulatory and postovulatory phases (P=0.012). In group B, there was a significant negative correlation between gestational week and intraocular pressure (IOP) (r=−0.322, P=0.024). Corneal volume was significantly higher during the early postpartum period than the late postpartum period in group C (P=0.028). Intraocular pressure, Goldman-correlated IOP, and corneal-compensated IOP differed significantly between the groups (P<0.05). Conclusions: Blood levels of estrogen and progesterone were associated with variations in IOP, but estrogen and progesterone did not have a consistent effect on topographic parameters or biomechanical properties in healthy corneas.
1 November 2017 in Eye & Contact Lens: Science & Clinical Practice
Objectives: Study aims to evaluate the indications and surgical techniques for corneal transplantation and to report changes in trends for preferred keratoplasty surgical techniques. Methods: Clinical records of 815 consecutive corneal transplantations between January 1, 2004 and December 31, 2014 in Haydarpasa Numune Training and Research Hospital Eye Clinic were analyzed and classified into seven broad groups according to indications. Main outcome measures were change of leading indications and trends for surgical techniques. Results: Leading indications for keratoplasty were keratoconus (KCN) (27.7%), bullous keratopathy (BK) (23%), postinfectious corneal scars (13.5%), regrafts (13.1%), corneal dystrophies (12.1%), and noninfectious corneal scars (5.4%). Regrafts were the only indication with a significantly increasing trend (P<0.01). Since the introduction of lamellar keratoplasty (LK) techniques including deep anterior lamellar keratoplasty (DALK) and Descemet stripping automated endothelial keratoplasty (DSAEK), there was a significant increasing trend in number and percentage of both LK techniques (DALK; P=0.001 and P=0.007, and DSAEK; P<0.001 and P<0.001, respectively) and a significant corresponding decline in the percentage of penetrating keratoplasty (PK) (P<0.01). Similarly, DALK and DSAEK replaced PK as the preferred surgical technique for KCN and BK indications, (P=0.007 and P=0.01, respectively). Although PK was the most common surgical technique over the 11-year period (54.7%), both anterior and posterior LK techniques showed an emerging trend as the procedures of choice when indicated. Conclusions: No major shift was observed in the clinical indications for corneal transplantation over the previous 11 years, except for regrafts. Lamellar keratoplasty techniques largely overtook the PK technique, but PK was still the overall preferred technique in the era when both LK techniques were used.