Johannes Schick

Mr. Johannes Schick


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JDJonas Paul David
Jonas Paul David
DSDavid Schick
David Schick
LRLorenz Rapp
Lorenz Rapp
JSJohannes Schick
Johannes Schick
MGMarkus Glaser
Markus Glaser
Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data were uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below that of most comparable systems. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.

1 January 2019
Verified
Conference Paper
Closed access
TWTobias Winter
Tobias Winter
JSJan Schnitzler
Jan Schnitzler
JSJohannes Schick
Johannes Schick
JPJulian Popp
Julian Popp
SISebastian Imle
Sebastian Imle
BBBernd Bertsche
Bernd Bertsche

10 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JDJonas Paul David
Jonas Paul David
DSDavid Schick
David Schick
LRLorenz Rapp
Lorenz Rapp
JSJohannes Schick
Johannes Schick
MGMarkus Glaser
Markus Glaser
Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data was uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below most of the comparable system. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.

2 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DSDavid Schick
David Schick
JSJohannes Schick
Johannes Schick
JDJonas Paul David
Jonas Paul David
RNRobin Neubauer
Robin Neubauer
MGMarkus Glaser
Markus Glaser
The behavior of pedestrians in a non-constrained environment is difficult to predict. In wearable robotics, this poses a challenge, since devices like lower-limb exoskeletons and active orthoses need to support different walking activities, including level walking and climbing stairs. While a fixed movement trajectory can be easily supported, switches between these activities are difficult to predict. Moreover, the demand for these devices is expected to rise in the years ahead. In this work, we propose a cloud software system for use in wearable robotics, based on geographical mapping techniques and Human Activity Recognition (HAR). The system aims to give context to the surrounding pedestrians by providing hindsight information. The system was partially implemented and tested. The results indicate a viable concept with great extensibility prospects.

19 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JDJonas Paul David
Jonas Paul David
JSJohannes Schick
Johannes Schick
RNRobin Neubauer
Robin Neubauer
MGMarkus Glaser
Markus Glaser
Ensuring user safety while enabling independent mobility is crucial to autonomous healthcare and rehabilitation robots, such as active lower-limb orthoses and exoskeletons. A key requirement for these devices is to provide full assistance without supervision; however, existing designs do not simultaneously satisfy autonomous operation and inherent safety. To address this gap, a novel safety principle, Safety by Design, and a corresponding system architecture for a fully assistive active knee orthosis are introduced. The proposed architecture is based on a comprehensive risk analysis for the use of active orthoses and exoskeletons and integrates redundancies for all safety-critical components while minimizing additional weight. This redundancy enables the orthosis to remain operational at reduced power in the event of component failure, improving both user safety and system reliability. The design supports safe, unsupervised operation by ambulatory users, enhancing independent patient mobility and the performance of the gait activities of level walking, stair climbing and sitting down/standing up. The proposed architecture is scalable and adaptable to a wide range of robotic devices. By improving robustness, efficiency, and safety, this work contributes to the advancement of autonomous biomedical robotic systems and wearable assistive devices.