Simon Viniol

Dr. Simon Viniol


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Emergency Radiology
Verified
Journal Article
Closed access
PDF file
SVSimon Viniol
Simon Viniol
RTR. P. Thomas
R. P. Thomas
AKA. M. König
A. M. König
SBS. Betz
S. Betz
AMA. H. Mahnken
A. H. Mahnken

1 November 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
AKAlexander König
Alexander König
JMJ. Maas
J. Maas
SVSimon Viniol
Simon Viniol
RER. Etzel
R. Etzel
MFM. Fiebich
M. Fiebich
AMA.H. Mahnken
A.H. Mahnken

1 October 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
SVSimon Viniol
Simon Viniol
RTR.P. Thomas
R.P. Thomas
SGS. Gombert
S. Gombert
AKA.M. König
A.M. König
SBS. Betz
S. Betz
AMA.H. Mahnken
A.H. Mahnken

21 July 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AKAlexander König
Alexander König
ASAnna Schweer
Anna Schweer
DSDaniel Sasse
Daniel Sasse
RERobin Etzel
Robin Etzel
JAJonas Apitzsch
Jonas Apitzsch
AMAndreas H. Mahnken
Andreas H. Mahnken
Objectives: Multiple studies show orthopedic health problems for medical staff due to wearing radiation protection aprons. The aim of this study was to evaluate the weight pressure on the shoulder as a marker of physical strain caused by different radiation-protection devices. Methods: For the weight pressure measurement, a pressure sensor (OMD-30-SE-100N, OptoForce, Budapest, Hungary) placed on the left and right shoulder was used. Wearing different radiation protection systems the force measurement system was used to quantify the weight pressure. Measurements were acquired in still standing position and during various movements. Results: A mean significant decreasing weight pressure on the shoulder between 74% and 84% (p<0.001) was measured, when the free-hanging radiation protection system was used in comparison to one-piece and two-piece radiation protection aprons and coats. Using two-piece radiation protection aprons, the weight pressure was significantly lower than that of one-piece radiation protection coats. If a belt was used for the one-piece radiation protection coat, the weight pressure on the shoulder was reduced by 32.5% (p = 0.003). For a two-piece radiation protection apron and a one-piece radiation protection coat (with and without belt) a significant different weight pressure distribution between the right and left shoulder could be measured. Conclusions: The free-hanging radiation protection system showed a significant lower weight pressure in comparison to the other radiation protection devices. Apart from this, use of a two-piece radiation protection apron or addition of a belt to a radiation protection coat proved to be further effective options to reduce weight pressure.

11 September 2019 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Open access
PDF file
JFJens Figiel
Jens Figiel
SVSimon Viniol
Simon Viniol
JGJannis Görlach
Jannis Görlach
ARAnja Rinke
Anja Rinke
DLDamiano Librizzi
Damiano Librizzi
AMAndreas H. Mahnken
Andreas H. Mahnken
Background Neuroendocrine neoplasms (NEN) are a heterogeneous group of tumors characterized by the expression of typical proteins. A wide range of morphological and functional imaging methods is required in order to adequately assess the course of the disease and to optimally treat the patient. The spectrum of indications ranges from the detection of small primary tumors to the documentation of the metastasis pattern and the assessment of the suitability for certain invasive or noninvasive therapy methods. The exact recording and quantification of findings is indispensable. Methods This article is based on a comprehensive literature search on the different aspects of neuroendocrine neoplasm imaging. Results This article is intended to provide an overview of the available imaging procedures with their respective advantages and disadvantages for diagnostics and their value for the follow-up of neuroendocrine neoplasms. Recommendations for examination protocols, typical image findings, and an outlook regarding future developments are presented. Key Points: Citation Format

1 July 2017 in Intensiv- und Notfallbehandlung
Verified
Journal Article
Closed access
SVSimon Viniol
Simon Viniol
AMA. Mahnken
A. Mahnken