Gabriel Fischer-Szava

Dr. Gabriel Fischer-Szava


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2013 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
TFTyler S Fisher
Tyler S Fisher
DGDustin A Gress
Dustin A Gress
RLRick Layman
Rick Layman
MMMichael F McNitt-Gray
Michael F McNitt-Gray
LFLynne A Fairobent
Lynne A Fairobent
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.

13 February 2009 in Malaria Journal
Verified
Journal Article
Open access
PDF file
WMWard P Myers
Ward P Myers
AMAndrea P Myers
Andrea P Myers
JCJanet Cox-Singh
Janet Cox-Singh
HLHui C Lau
Hui C Lau
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
RMRick Malley
Rick Malley
Knowledge of geography is integral to the study of insect-borne infectious disease such as malaria. This study was designed to evaluate whether geographic parameters are associated with malarial infection in the East Sepik province of Papua New Guinea (PNG), a remote area where malaria is a major cause of morbidity and mortality.

6 January 2014 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
AVAndrew Vassil
Andrew Vassil
RTRahul Tendulkar
Rahul Tendulkar
JBJohn Bayouth
John Bayouth
PXPing Xia
Ping Xia
Removing a flattening filter or replacing it with a thinner filter alters the characteristics of a photon beam, creating a forward peaked intensity profile to make the photon beam nonflat. This study is to investigate the feasibility of applying nonflat photon beams to the whole-breast irradiation with breath holds for a potential of delivery time reduction during the gated treatment. Photon beams of 6 MV with flat and nonflat intensity profiles were commissioned. Fifteen patients with early-stage breast cancer, who received whole-breast radiation without breathing control, were retrospectively selected for this study. For each patient, three plans were created using a commercial treatment planning system: (a) the clinically approved plan using forward planning method (FP); (b) a hybrid intensity-modulated radiation therapy (IMRT) plan where the flat beam open fields were combined with the nonflat beam IMRT fields using direct aperture optimization method (mixed DAO); (c) a hybrid IMRT plan where both open and IMRT fields were from nonflat beams using direct aperture optimization (nonflat DAO). All plans were prescribed for ?95% of the breast volume receiving the prescription dose of 50 Gy (2.0 Gy per fraction). In comparison, all plans achieved a similar dosimetric coverage to the targeted volume. The average homogeneity index of the FP, mixed DAO, and nonflat DAO plans were 0.8820.024 , 0.8790.023 , and 0.8670.027 , respectively. The average percentage volume of V105 was 57.66%5.21% , 34.67

30 January 2020 in Postgraduate Medicine
Verified
Journal Article
Closed access
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
PAINWeek abstract book 2020. Postgraduate Medicine. Accepted .

8 May 2014 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
AAAndrew Alexander
Andrew Alexander
RRRussell Ruo
Russell Ruo
ECEunah Chung
Eunah Chung
JSJan Seuntjens
Jan Seuntjens
MFMark J. Foley
Mark J. Foley
IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at the planned gantry angle (rotated delivery). We examined, established, and optimized Monte Carlo simulations of the dosimetry for IMRT verification of treatment plans for these two different delivery modes (collapsed versus rotated). The results of the simulations were compared to the treatment planning system dose calculations for the two delivery modes, as well as to measurements taken. This was done in order to investigate the validity of the use of a collapsed delivery technique for IMRT QA. The BEAMnrc, DOSXYZnrc, and egs_chamber codes were utilized for the Monte Carlo simulations along with the MMCTP system. A number of different plan complexity metrics were also used in the analysis of the dose distributions in a bid to qualify why verification in a collapsed delivery may or may not be optimal for IMRT QA. Following the Alfonso et al.(1) formalism, the kQclin,Qfclin,fref correction factor was calculated to correct the deviation of small fields from the reference conditions used for beam calibration. We report on the results obtained for a cohort of 20 patients. The plan complexity was investigated for each plan using the complexity metrics of homogeneity index, conformity index, modulation complexity score, and the fraction of beams from a particular plan that intersect the chamber when performing the QA. Rotated QA gives more consistent results than the collapsed QA technique. The kQclin,Qfclin,fref factor deviates less from 1 for rotated QA than for collapsed QA. If the homogeneity index is less than 0.05 then the kQclin,Qfclin,fref factor does not deviate from unity by more than 1%. A value this low for the homogeneity index can only be obtained with the rotated QA technique. PACS number: 87.55.Qr

14 May 2025 in Social Sciences
Verified
Journal Article
Open access
PDF file
ESElizabeth Alice Sweigart
Elizabeth Alice Sweigart
GFGabriel Fischer-Szava
Gabriel Fischer-Szava
PWPamela Wisniewski
Pamela Wisniewski
Stakeholders from parents to policy-makers are concerned about youth online safety. Present solutions are frequently punitive and often lack opportunities for youth to make mistakes and try again in a safe environment. This paper proposes a new framework, based on trauma-informed child psychology models and research by computer scientists and human-centered design scholars, entitled Pause, Reflect, and Redirect (PRR). The PRR framework offers three levels of intervention ranging from casual engagement to coached engagement with crisis response. To further develop and validate PRR as a framework, PRR was implemented within a web-filtering software that was installed in a public middle school comprising grades 6 to 8 (i.e., ages 11–14) in an urban charter district. Preliminary results from the deployment of the software suggest that it may help youth make better choices with respect to their online behaviors.