In this work, 13 jet nebulizers, some of which in different configurations, were investigated in order to identify the biopharmaceutical constraints related to the quality attributes of the medicinal products, which affect their safety, efficiency, compliance, and effectiveness. The aerosolization parameters, including the aerosol output, aerosol output rate, mass median aerodynamic diameter, and fine particle fraction, were determined according to the European Standard EN 13544-1, using sodium fluoride as a reference formulation. A comparison between the aerosol output nebulization time and the fine particle fraction displayed a correlation between the aerosol quality and the nebulization rate. Indeed, the quality of the nebulization significantly increased when the rate of aerosol emission was reduced. Moreover, the performance of the nebulizers was analyzed in terms of respirable delivered dose and respirable dose delivery rate, which characterize nebulization as the rate and amount of respirable product that could be deposited into the lungs. Depending on which of these two latter parameters was used, the nebulizers showed different performances. The differences, in terms of the rate and amount of delivered aerosol, could provide relevant information for the appropriate choice of nebulizer as a function of drug product, therapy, and patient characteristics.
The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5–7 days at room temperature, followed by 2–3 days at 30–35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light-amber solutions. In addition, the reliability of the nutrient medium and the process was demonstrated by positive growth promotion tests with S. epidermidis. During automated preparation the recommended limits < 1 cfu per settle/contact plate set for cleanroom Grade A zones were not succeeded in the carousel and working area, but in the loading area of the robot. During manual preparation, the number of cfus detected on settle/contact plates inside the workbenches lay far below the limits. The number of cfus detected on fingertips succeeded several times the limit during manual preparation but not during automated preparation. There was no difference in the microbial contamination rate depending on the extent of cleaning and disinfection of the robot. Extensive media-fill tests simulating manual and automated preparation of ready-to-use cytotoxic injection solutions revealed the same level of sterility for both procedures. The results of supplemental environmental controls confirmed that the aseptic procedures are well controlled. As there was no difference in the microbial contamination rates of the media preparations depending on the extent of cleaning and disinfection of the robot, the results were used to adapt the respective standard operating procedures.
21 May 2020 in Pharmaceutical Technology in Hospital Pharmacy
All dosage forms prepared in hospital pharmacies should be labelled with an appropriate shelf-life. This shelf-life should be validated taking chemical, physical and microbiological data into consideration. This guidance focuses on parenteral aseptically prepared products, as they are high-risk preparations. The risk is exacerbated by a requirement for longer shelf lives for reasons of economy and efficiency. The scope of this guidance includes individual patient preparations, preparations prepared in series (same type of preparation being repeatedly prepared) and batch preparations prepared from the same initial bulk admixture.
Autoantibodies (Ab) against the thyrotropin receptor (TSH-R-Ab) are key mediators for the pathogenesis of Graves' disease (GD). TSH-R-Ab degradation was evaluated using several immunoassays within an exploratory, controlled trial in patients with GD receiving a monoclonal antibody (mAb) targeting the neonatal crystallizable fragment receptor (FcRn). Serial measurements of TSH-R-Ab serum levels were performed using three different binding and cell-based assays in GD patients either on medication or on placebo. In contrast to placebo where no changes were observed, a 12-week mAb therapy led to an early and significant decrease (> 60%) of the serum TSH-R-Ab serum levels in patients with thyroidal and extra-thyroidal GD, as unanimously shown in all three assays. These marked changes were noted already at week seven post baseline (P<0.0001 for the binding immunoassay and for the luciferase (readout) bioassay. The three TSH-R-Ab binding and bioassays highly correlated in the samples of both study groups (binding immunoassay versus luciferase bioassay r = 0.91, P < 0.001, binding vs. cyclic adenosine monophosphate (cAMP) bioassay, r = 0.86, P < 0.001, luciferase versus cAMP bioassay, r = 0.71, P = 0.006). The serological results correlated with the course of the extra-thyroidal clinical parameters of GD, i.e. clinical activity score and proptosis. Targeting the FcRn markedly reduces the disease-specific TSH-R-Ab in patients with GD. The novel and rapid TSH-R-Ab bioassay improves diagnosis and management of GD patients.
1 June 2014 in Pulmonary Pharmacology & Therapeutics