Marc-Olivier Fischer

Dr. Marc-Olivier Fischer


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
MFMarc-Olivier Fischer
Marc-Olivier Fischer
RAR. Avram
R. Avram
ICI. Cârjaliu
I. Cârjaliu
MMM. Massetti
M. Massetti
JGJ. L. Gérard
J. L. Gérard
JFJ. L. Fellahi
J. L. Fellahi
This observational study was designed to evaluate the reliability and precision of a new digital photoplethysmographic device (Nexfin, BMEYE B.V., Amsterdam, The Netherlands) for continuous and non-invasive assessment of arterial pressure and cardiac output. Fifty consecutive adult subjects were prospectively enrolled at admission to the intensive care unit after conventional cardiac surgery and investigated hourly from T0 to T4. Simultaneous comparative systolic, diastolic, and mean arterial pressures and cardiac index (CI) data points were collected from an invasive radial artery catheter, transpulmonary thermodilution catheter, and the Nexfin device. Correlations were determined by linear regression. The Bland–Altman analysis was used to compare bias, precision, and limits of agreement. Six (12%) subjects were excluded from the analysis because of the inability to obtain a reliable photoplethysmographic signal. No complications were observed. A significant relationship was found between absolute values of photoplethysmographic and radial systolic (r2=0.56, P<0.001), diastolic (r2=0.61, P<0.001), and mean (r2=0.77, P<0.001) arterial pressures. A significant relationship was also found between transpulmonary thermodilution and Nexfin CI absolute values (r2=0.33, P<0.001). Bias, precision, and limits of agreement between the mean photoplethysmographic and radial arterial pressures were 4.6 (95% confidence interval: 3.7–5.5), 6.5, and −17.3 to 8.1 mm Hg, respectively. The percentage error between transpulmonary thermodilution and the Nexfin for CI measurement was 50%. The Nexfin device is safe, convenient, and reliable in measuring continuous non-invasive arterial pressure but not interchangeable with transpulmonary thermodilution to monitor CI.

1 August 2022 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
MFMarc-Olivier Fischer
Marc-Olivier Fischer
FBFrançois Brotons
François Brotons
ABAnais R. Briant
Anais R. Briant
KSKoichi Suehiro
Koichi Suehiro
WGWaldemar Gozdzik
Waldemar Gozdzik
AOAlexandre Ouattara
Alexandre Ouattara

25 March 2013 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
MFMarc-Olivier Fischer
Marc-Olivier Fischer
JCJ. Coucoravas
J. Coucoravas
JTJ. Truong
J. Truong
LZL. Zhu
L. Zhu
JGJ. ‐L. Gérard
J. ‐L. Gérard
JFJ. ‐L. Fellahi
J. ‐L. Fellahi

1 January 2022 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
MFMarc-Olivier Fischer
Marc-Olivier Fischer
PGPierre-Grégoire Guinot
Pierre-Grégoire Guinot
SDStéphane Debroczi
Stéphane Debroczi
PHPierre Huette
Pierre Huette
CBChristophe Beyls
Christophe Beyls
OAOsama Abou-Arab
Osama Abou-Arab

1 July 2019 in Journal of Hospital Infection
Verified
Journal Article
Closed access
VBV. Bonnet
V. Bonnet
HDH. Dupont
H. Dupont
SGS. Glorion
S. Glorion
MAM. Aupée
M. Aupée
EKE. Kipnis
E. Kipnis
MFMarc-Olivier Fischer
Marc-Olivier Fischer

1 December 2013 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
MFMarc-Olivier Fischer
Marc-Olivier Fischer
APArnaud Pelissier
Arnaud Pelissier
DBDan Bohadana
Dan Bohadana
JGJean-Louis Gérard
Jean-Louis Gérard
JHJean-Luc Hanouz
Jean-Luc Hanouz
JFJean-Luc Fellahi
Jean-Luc Fellahi