Cem Zeki Esenyel

Prof. Dr. Cem Zeki Esenyel

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2006 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
CECem Zeki Esenyel
Cem Zeki Esenyel
MDMehmet Demirhan
Mehmet Demirhan
MEMeltem Esenyel
Meltem Esenyel
MSMesut Sonmez
Mesut Sonmez
SKSinan Kahraman
Sinan Kahraman
TOTaskin Ozdes
Taskin Ozdes

4 January 2009 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
PDF file
CECem Zeki Esenyel
Cem Zeki Esenyel
MDMehmet Demirhan
Mehmet Demirhan
OKOnder Kilicoglu
Onder Kilicoglu
OAOktay Adanir
Oktay Adanir
BBBilge Bilgic
Bilge Bilgic
SOSerhat Ozsoy
Serhat Ozsoy
Objectives: We evaluated the inflammatory reactions induced by three commonly used nonabsorbable suture materials in a rabbit model.\r\nMethods: Three suture materials were tested: braided polyester suture (Ethibond), braided blend of polyester and polyethylene suture (FiberWire), and monofilament polypropylene suture (Polypropylene). Thirty-six rabbits were randomly allocated to three suture groups, equal in number. Each suture type was placed bilaterally in the quadriceps muscle, patellar tendon, knee joint capsule, and Achilles tendon. Six animals in each group were sacrificed in the third and sixth weeks. The inflammation induced by each suture was assessed using light microscopy and the width of the inflammation zone (WIZ) was measured.\r\nResults: Ethibond was found to cause the most severe reaction in the muscle and tendon in the third week; in the sixth week, however, it showed the lowest inflammatory reaction in all tissue types. Reaction to Propylene was moderate in the third week, whereas it caused the largest WIZ in all tissue types in the sixth week, such that the eventual size of the WIZ induced by Propylene (6.6±2.1 mm) was significantly greater than that of Ethibond (1.6±0.9 mm) in muscle specimens (p<0.05). Except for the largest WIZ seen in joint capsule specimens in the third week, inflammatory reactions associated with FiberWire were low or moderate in all tissue specimens throughout the study. FiberWire was associated with some necrotic areas in two muscle and one tendon specimens. \r\nConclusion: The extent of inflammatory reaction to nonabsorbable suture materials depends on the type of suture material, tissue type, and the duration of postoperative time. Özet Amaç: Sık kullanılan üç emilmeyen dikiş malzemesinin dokuda oluşturduğu enflamatuvar yanıtlar tavşan modelinde değerlendirildi.\r\nÇalışma planı: Çalışmada, örgülü polyester (Ethibond), monofilaman polipropilen (Polypropylene) ve örgülü polietilen ve polyester karışımı (FiberWire) dikiş malzemesi kullanıldı. Otuz altı adet tavşan, kullanılan dikiş materyaline göre, eşit sayıda üç gruba ayrıldı. Her bir dikiş malzemesi tavşanın her iki bacağındaki kuadriseps kasına, patellar tendona, diz eklem kapsülüne ve Aşil tendonuna uygulandı. Her gruptaki altışar tavşan üçüncü ve altıncı haftalarda öldürüldü. Dikiş malzemesinin oluşturduğu enflamatuvar yanıt ışık mikroskobu kullanılarak değerlendirildi ve enflamatuvar alanın genişliği ölçüldü.\r\nSonuçlar: Üçüncü haftada kas ve tendonda en şiddetli enflamatuvar yanıtı Ethibond oluştururken, Ethibond’a bağlı yanıt altıncı haftada tüm dokularda en az düzeydeydi. Üçüncü haftada Propilen’in oluşturduğu yanıt orta düzeyde iken, altıncı haftada tüm dokularda en geniş enflamatuvar alana sahipti. Altıncı haftada kasta Propilen’in oluşturduğu enflamatuvar alan genişliği (6.6±2.1 mm) Ethibond’un oluşturduğundan (1.6±0.9 mm) anlamlı derecede fazlaydı (p<0.05). FiberWire üçüncü haftada eklem kapsülünde en geniş enflamatuvar yanıtı oluşturdu, fakat diğer dokularda üçüncü ve altıncı haftalarda oluşan enflamatuvar yanıt düşük veya orta düzeydeydi. İki kas ve bir tendon örneğinde FiberWire’a bağlı bazı nekrotik alanlar görüldü.\r\nÇıkarımlar: Emilmeyen dikiş malzemelerine karşı oluşan enflamatuvar yanıt, materyalin cinsine, doku tipine ve ameliyat sonrası geçen süreye bağlıdır.

13 January 2009 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
CECem Zeki Esenyel
Cem Zeki Esenyel
KOKahraman Ozturk
Kahraman Ozturk
MDMehmet Demirhan
Mehmet Demirhan
MSMesut Sonmez
Mesut Sonmez
SKSinan Kahraman
Sinan Kahraman
BSBerna Senel
Berna Senel

3 January 2010 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
PDF file
CECem Zeki Esenyel
Cem Zeki Esenyel
KOKahraman Ozturk
Kahraman Ozturk
MBMurat Bulbul
Murat Bulbul
SASemih Ayanoglu
Semih Ayanoglu
HCHasan Huseyin Ceylan
Hasan Huseyin Ceylan
Objectives: We evaluated the long-term results of acromioclavicular dislocations treated with coracoclavicular fixation using a cancellous screw.\r\nMethods: Coracoclavicular fixation was performed using the modified Bosworth technique in 32 patients (24 males, 8 females; mean age 35 years; range 19 to 58 years) with acromioclavicular dislocations. According to the Rockwood classification, seven patients had type III, nine patients had type IV, 13 patients had type V, and three patients had type VI dislocations. Following repair of the coracoclavicular ligament, fixation was performed with a cancellous screw in all but two patients in whom a cortical screw was used. These two patients developed redislocation due to screw cut out and underwent reoperation with cancellous screw fixation and were not included in the final assessments. The screws were removed under local anesthesia after eight weeks postoperatively. The patients were evaluated for cosmetic appearance, functional status, pain, localized tenderness, articular range of motion, and with the functional Constant scoring system. The mean follow up was 3.1 years (range 1 to 8 years). \r\nResults: The mean Constant score was 98 (range 92 to 100). The results were excellent in 26 patients (86.7%) and good in four patients (13.3%). There was subluxation of the acromioclavicular joint in one patient (3.3%). The alignment of the acromioclavicular joint was normal in the remaining patients. None of the patients showed joint degeneration. All patients were pain-free and achieved full range of motion.\r\nConclusion: With ease of application, low complication rate, and low rate of acromioclavicular joint arthrosis, the modified Bosworth technique is an effective surgical method in providing satisfactory shoulder function in acromioclavicular dislocations.

1 January 2011 in The Eurasian Journal of Medicine
Verified
Journal Article
Open access
TATugrul Alici
Tugrul Alici
CECem Zeki Esenyel
Cem Zeki Esenyel
MEMeltem Esenyel
Meltem Esenyel
YIYunus Imren
Yunus Imren
SASemih Ayanoglu
Semih Ayanoglu
RCRahmi Cubuk
Rahmi Cubuk
Objective: The geometry of the tibial plateau has a direct influence on the translation and the screw home biomechanics of the tibiofemoral joint. Little information on the relationship between the tibial slope and meniscal lesions is available. The objective of this retrospective study was to examine the effect of the tibial slope on the medial and lateral meniscus lesions in patients with intact ACLs. Materials and Methods: The MRIs and lat roentgenograms of 212 patients with meniscus lesions were examined to determine the possible effect of the tibial slope on meniscal tears. First, the anatomic axis of the proximal tibia was established. Then, the angle between the line drawn to show the tibial slopes (medial and lateral) and the line drawn perpendicular to the proximal tibial anatomic axis was established on MRI. The patients with previously detected meniscus lesions were classified into three categories: patients with only medial meniscal tear (Group 1, 90 patients); patients with only lateral meniscal tear (Group 2, 15 patients); and patients with both medial and lateral meniscal tear (Group 3, 19 patients). Group 4 had no meniscal tear (88 patients). The MRIs of the patients who had applied to the Orthopedic Outpatient Clinic with patellofemoral pain and no meniscal tear were included as the control group. Results: The average tibial slope of the medial tibial plateau was 3.18° in group 1, 3.64° in group 2, 3° in group 3, and 3.27° in group 4. The average tibial slope of the lateral tibial plateau was 2.88° in group 1, 3.6° in group 2, 2.68 in group 3, and 2.91 in group 4. The tibial slope on the medial tibial plateau was significantly larger than the lateral tibial plateaus in group 1 and group 4 (p0.05). In addition, the tibial slope on the lateral side of group 2 was significantly larger than that of groups 1, 3, and 4 (p<0.05). Conclusion: An increase in the tibial slopes, especially on the lateral tibial plateau, seems to increase the risk of meniscal tear.

28 March 2012 in Rheumatology International
Verified
Journal Article
Closed access
PDF file
MEMeltem Esenyel
Meltem Esenyel
AIAfitap İçağasıoğlu
Afitap İçağasıoğlu
CECem Zeki Esenyel
Cem Zeki Esenyel