Kui Liu

Kui Liu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2025 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
JLJun Luo
Jun Luo
SBShaojun Bai
Shaojun Bai
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
HDHao Dang
Hao Dang
JMJianwei Mei
Jianwei Mei
TianQin is a future space-based gravitational wave (GW) observatory targeting the frequency window of 10−4–1 Hz. A large variety of GW sources are expected in this frequency band, including the merger of massive black hole binaries, the inspiral of extreme/intermediate mass ratio systems, stellar-mass black hole binaries, Galactic compact binaries, and so on. TianQin will consist of three Earth orbiting satellites on nearly identical orbits with orbital radii of about 105 km. The satellites will form a normal triangle constellation whose plane is nearly perpendicular to the ecliptic plane. The TianQin project has been progressing smoothly following the ‘0123’ technology roadmap. In step ‘0’, the TianQin laser ranging station has been constructed and it has successfully ranged to all the five retro-reflectors on the Moon. In step ‘1’, the drag-free control technology has been tested and demonstrated using the TianQin-1 satellite. In step ‘2’, the inter-satellite laser interferometry technology will be tested using the pair of TianQin-2 satellites. The TianQin-2 mission has been officially approved and the satellites will be launched around 2026. In step ‘3’, i.e. the TianQin-3 mission, three identical satellites will be launched around 2035 to form the space-based GW detector, TianQin, and to start GW detection in space.

19 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KLKui Liu
Kui Liu
FZFenglei Zhang
Fenglei Zhang
ZLZongyang Li
Zongyang Li
XFXiaohua Feng
Xiaohua Feng
KLKe Li
Ke Li
Jie ZhangJie Zhang
Jie Zhang
Large-scale laser gyroscopes have found important applications in Earth sciences due to their self-sufficient property of measurement of the Earth’s rotation without any external references. In order to extend the relative rotation measurement accuracy to a better level so that it can be used for the determination of the Earth orientation parameters (EOP), we investigate the limitations in a passive resonant laser gyroscope (PRG) developed at Huazhong University of Science and Technology (HUST) to pave the way for future development. We identify the noise sources from the derived noise transfer function of the PRG. In the frequency range below 10−2Hz, the contribution of free-spectral-range (FSR) variation is the dominant limitation, which comes from the drift of the ring cavity length. In the 10−2 to 103Hz frequency range, the limitation is due to the noises of the frequency discrimination system, which mainly comes from the residual amplitude modulation (RAM) in the frequency range below 2 Hz. In addition, the noise contributed by the Mach–Zehnder-type beam combiner is also noticeable in the 0.01 to 2 Hz frequency range. Finally, possible schemes for future improvement are also discussed.

30 November 2020 in Journal of Asthma
Verified
Journal Article
Open access
MJMeng Jin
Meng Jin
CCCan Chen
Can Chen
JHJinyu Huang
Jinyu Huang
FZFengqin Zhang
Fengqin Zhang
TDTianyi Dong
Tianyi Dong
HZHuilan Zhang
Huilan Zhang
Although it is reported that patients with coronavirus disease 2019 (COVID-19) disease who have comorbidities are at higher risk to suffer adverse clinical outcomes, there are inadequate evidence t...

1 April 2025 in Photonics Research
Verified
Journal Article
Closed access
DLDanqing Liu
Danqing Liu
CGChanglei Guo
Changlei Guo
CMChunzhao Ma
Chunzhao Ma
WFWeitong Fan
Weitong Fan
XGXuezhen Gong
Xuezhen Gong
HYHsien-Chi Yeh
Hsien-Chi Yeh
He-Ne gaseous ring-laser gyroscopes (RLGs) have brought great breakthroughs in numbers of fields such as inertial navigation and attitude control in the past 50 years. However, their counterparts of all-solid-state, active RLGs have been far behind even though they have a few indispensable advantages. Here, we propose and demonstrate an all-solid-state, active RLG based on a millimeter-sized, single monolithic non-planar ring oscillator (NPRO) with a gain medium of Nd:YAG crystal or Nd-glass. The clockwise (CW) and counter-clockwise (CCW) laser modes in NPRO are simultaneously initiated under a regime of laser feedback interferometry, whose nonzero frequency difference intrinsically formats the single monolithic NPRO working as a Sagnac laser gyroscope without a noticeable lock-in effect. The higher wavefront distortion in NPRO samples is revealed to introduce less mode competition (higher beat frequency stability) between the two laser modes, which is a precondition to build the NPRO gyroscope. Under a free-running condition, the NPRO gyroscope typically has a bias instability of 31.3 deg/h and an angle random walk of 0.22 deg/h with a scale factor of 38.3 Hz/(deg s−1), and the instability is mainly caused by the magnetic noise at present. The NPRO gyroscope can be enclosed in a centimeter-sized package, with a power consumption below 0.7 W and a mass under 20 g. Moreover, the stability performance can be further improved by NPRO design and active noise suppression in the future. Such compact, low-power-consumed, and highly stable RLGs may find important applications in aerospace, defense, and industry.

31 January 2023 in Applied Optics
Verified
Journal Article
Closed access
XFXiaohua Feng
Xiaohua Feng
KLKui Liu
Kui Liu
YCYuxuan Chen
Yuxuan Chen
HZHaobo Zhang
Haobo Zhang
ZLZongyang Li
Zongyang Li
JZJie Zhang
Jie Zhang
Large-scale laser gyroscopes with sufficiently high sensitivity for measurement of the rotation rate of the Earth Ω E are inertial sensors with the capability to provide Earth orientation parameters, i.e., rotation rate and polar motion in near real time. Larger-scale passive resonant gyroscopes (PRGs) theoretically have a lower shot-noise limit. However, the cavity perimeter fluctuations and laser frequency noise become challenges in a passive gyro. In this paper, we introduce a three-wave differential locking scheme for large-scale PRGs, resulting in an in situ measurement of the cavity perimeter with nanometer resolution. Furthermore, the laser frequency noise is effectively suppressed with an additional gain of 30 dB by a double-stage locking system, based on the three-wave differential locking scheme. Finally, the rotation rate resolution of our 3 m × 3 m gyroscope improves to 1.1 × 10 − 9 r a d / s over 200 s. The simplicity, robustness, and effectiveness of the locking scheme are important to the long-term operation of large-scale PRGs aiming for applications in the geosciences.

4 June 2025 in Optics Letters
Verified
Journal Article
Closed access
PDF file
YCYuxuan Chen
Yuxuan Chen
YZYuhong Zhong
Yuhong Zhong
KLKui Liu
Kui Liu
YLYawen Liu
Yawen Liu
YCYangsheng Cai
Yangsheng Cai
JLJun Luo
Jun Luo
Large-scale laser gyroscopes with high resolution are widely used in Earth rotation sensing and geophysical detection. We demonstrate a giant 64 m2 green laser gyroscope in a passive running mode. By adopting a heterolithic architecture and using a 532 nm solid state laser as the light source, the gyroscope demonstrates a short wavelength, a large-scale factor, and currently the highest Q-factor of 6 × 1012 among existing gyroscopes. A minimum sensitivity of 7×10−11rad/s/Hz is achieved, which is the best performance among passive ring gyroscopes (PRGs) to the best of our knowledge. This high sensitivity allows detection of terrestrial secondary microseismic signal at about 0.25 Hz, demonstrating the application value of large-scale PRGs in the field of geophysics. With a theoretical shot-noise limit of 1×10−12rad/s/Hz, the PRG offers a promising solution for future detection of Earth rotation with extreme sensitivity.