Background: The development of conveniently sprayed, tissue‐adherent, inert hydrogel films has made possible the creation of novel products that can serve a dual function, as a surgical sealant to achieve immediate hemostasis, and as a barrier to prevent adhesion formation over time. Methods: A sprayable, in situ formed absorbable hydrogel film was evaluated as a tissue sealant in a heparinized canine carotid artery graft model. PTFE grafts with leaking end‐to‐side anastomoses were treated with the synthetic sealant, and hemostasis was evaluated upon restoration of blood flow. Also, the hydrogel films were evaluated as an adhesion barrier in a rabbit pericardial abrasion model. Results: The sprayable, in situ forming hydrogel film was shown to immediately seal carotid‐PTFE anastomoses in six of six applications. Hydrogel application in a rabbit pericardial abrasion model resulted in a statistically significant reduction in the number and tenacity of adhesions. Conclusions: This novel in situ formed sprayable hydrogel film has demonstrated a dual function as an effective tissue sealant and as an adhesion barrier in cardiovascular preclinical models. These next generation synthetic biomaterials are currently undergoing clinical investigations. (J Card Surg 2003;18:494‐499)
1 January 1999 in Journal of Investigative Surgery
Adhesion formation after bowel surgery is a significant problem. The objective of this study was to evaluate two adhesion barriers composed of oxidized regenerated cellulose (ORC) in a model of bowel surgery, with and without bleeding. Ceca of female New Zealand White rabbits were abraded with gauze and a 3x5 cm patch of peritoneum and underlying muscle was excised from the right sidewall. Animals were randomized to receive no treatment, INTERCEED Barrier (Ethicon, Inc.), or neutralized INTERCEED (nTC7). ORC fabrics were applied to the excision site. Seven days later the percentage of the site and length of cecum with adhesions were estimated. The study was replicated in the presence of blood by nicking small vessels near the site sufficient to saturate the fabrics with blood. With hemostasis, the percentage of the sidewall with adhesions was reduced (p < .01) from 63.2 +/- 14.7% in controls (n=6) to 4 +/- 2.7% with INTERCEED Barrier(n=6) and 3 +/- 1.2% (n=5) with nTC7. With bleeding, however, control (n=5) levels of adhesions (67 +/- 17.5%) were reduced significantly with nTC7 (5.5 +/- 4%, n=4; p < .01), but not INTERCEED Barrier (34.2 +/- 18.4%, n=4). Similar trends were observed when the extent of adherent cecum was examined, since the cecum was the main site of adherence to the sidewall. However in the presence of blood, there was no effect of INTERCEED Barrier on cecal adhesions. We conclude that with hemostasis, both absorbable fabrics of ORC reduced adhesion formation between the injured cecum and abdominal sidewall. The effectiveness of INTERCEED Barrier, but not nTC7, was reduced but not eliminated in the presence of bleeding. This confirms similar observations in models of gynecologic surgery.