Israa Salameh

Mrs. Israa Salameh


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2026 in Microorganisms
Verified
Journal Article
Open access
PDF file
AIAHMED ISMAIL
AHMED ISMAIL
ISIsraa Salameh
Israa Salameh
NYNadin Younes
Nadin Younes
PBParveen Banu
Parveen Banu
SAShaden Abunasser
Shaden Abunasser
Gheyath NasrallahGheyath Nasrallah
Gheyath Nasrallah
Human immunodeficiency virus (HIV) remains a major global health challenge, requiring accurate diagnostic testing for early detection. Chemiluminescent immunoassay screening, particularly the Architect HIV Ag/Ab Combo assay, followed by immunoblot confirmation using INNO-LIA™ has traditionally been used in many diagnostic workflows. To address these limitations, the U.S. Centers for Disease Control and Prevention (CDC) recommends the use of an HIV-1/2 antibody differentiation immunoassay, such as the Geenius HIV-1/2 Supplemental Assay, as part of the confirmatory testing algorithm. This study evaluates the performance of two rapid HIV-1/2 confirmatory assays—the Multisure HIV-1/2 Confirmatory Test and the Bio-Rad Geenius HIV-1/2 Supplemental Assay—within a CDC-aligned diagnostic framework, with the aim of assessing Multisure as a potential alternative differentiation assay. A total of 224 archived serum samples were analyzed, including true positives (n = 38), true negatives (n = 139), false positives (n = 20), and INNO-LIA™ indeterminate samples (n = 27), as defined by Architect HIV and INNO-LIA™ results. Samples were initially screened using the Architect HIV Ag/Ab Combo assay, confirmed by INNO-LIA™ and PCR, and subsequently re-tested using Multisure HIV-1/2 and Geenius HIV-1/2 assays. Diagnostic performance metrics were evaluated. Both rapid assays demonstrated 100% sensitivity and specificity when compared with INNO-LIA™. Among INNO-LIA™ indeterminate samples, Multisure HIV-1/2 classified 81.5% as negative compared with 55.6% using Geenius HIV-1/2. When compared with PCR, Multisure demonstrated higher specificity (89.2%) and positive predictive value (89.5%) than Geenius (82.9% and 84.6%). No confirmed HIV-2 infections were identified in the analyzed dataset, and HIV-1 subtype information was not available for the archived samples; therefore, conclusions regarding HIV-1/2 differentiation are based primarily on assay design and antigenic targets. Multisure HIV-1/2 demonstrated strong diagnostic performance comparable to established differentiation assays and may represent a practical alternative rapid confirmatory option within CDC-aligned HIV diagnostic workflows. Further studies including larger datasets and confirmed HIV-2 infections are warranted to further validate its clinical utility.

9 June 2026 in Microorganisms
Verified
Journal Article
Open access
PDF file
AIAHMED ISMAIL
AHMED ISMAIL
SAShaden Abunasser
Shaden Abunasser
ISIsraa Salameh
Israa Salameh
MAMazen Najib Abou Assali
Mazen Najib Abou Assali
MEManal Elshaikh
Manal Elshaikh
Gheyath NasrallahGheyath Nasrallah
Gheyath Nasrallah
Fourth-generation immunoassays are widely used for HIV and syphilis screening; however, false-reactive results may increase confirmatory testing and operational burden in high-throughput laboratories. This study evaluated the comparative performance of automated chemiluminescent immunoassays (MAGLUMI® HIV Ab/Ag Combi (Snibe Diagnostics Co. Ltd., Shenzhen, China), VITROS® ECiQ HIV Combo (Ortho Clinical Diagnostics, Raritan, NJ, USA), MAGLUMI® Syphilis (Snibe Diagnostics Co. Ltd., Shenzhen, China), and ARCHITECT® Syphilis TP (Abbott Diagnostics, Abbott Park, IL, USA) within a routine diagnostic algorithm, incorporating antibody differentiation immunoassays (INNO-LIA® HIV I/II Score (Fujirebio Europe N.V., Ghent, Belgium) and HIV-1 RNA PCR where applicable. A total of 240 archived serum samples for HIV testing and 180 for syphilis testing were analyzed. Agreement-based performance measures including sensitivity, specificity, overall percent agreement (OPA), and Cohen’s kappa (κ) were calculated as comparator-based estimates reflecting concordance within the routine diagnostic algorithm rather than absolute diagnostic accuracy against a universal reference standard. For comparisons with HIV-1 RNA PCR, positive and negative concordance rates are reported to reflect agreement between assays detecting different biological targets. Among samples with definitive (positive or negative) results, the MAGLUMI® HIV Ab/Ag Combi assay showed complete agreement with INNO-LIA® HIV I/II Score (κ = 1.00) and high agreement with PCR within the ARCHITECT® HIV Ag/Ab Combo-reactive subset (κ = 0.90). The VITROS® ECiQ HIV Combo assay demonstrated high agreement with INNO-LIA® HIV I/II Score (κ = 0.916) and substantial agreement with PCR (κ = 0.715), with a lower negative concordance rate with PCR observed in the ARCHITECT-reactive subset. A parallel five-modality analysis of 11 discordant samples applying the CDC 2014 algorithm demonstrated that all three immunoassay platforms successfully detected confirmed HIV-seropositive individuals with controlled viremia despite negative PCR, while MAGLUMI® HIV Ab/Ag Combi produced fewer false-reactive results than both ARCHITECT® and VITROS® in this discordant subset. Additionally, two cases showed INNO-LIA® indeterminate results with positive PCR, consistent with acute HIV infection during the early seroconversion stage; all three immunoassay platforms produced signals above the non-reactive threshold in both cases. For syphilis testing, both MAGLUMI® Syphilis and ARCHITECT® Syphilis TP assays showed complete agreement with INNO-LIA® Syphilis Score among samples with definitive results (κ = 1.00). In contrast, the RPR assay showed reduced positive predictive value (49.4%) and moderate agreement with INNO-LIA® Syphilis Score (κ = 0.52). Automated chemiluminescent immunoassay (CLIA) platforms demonstrated high agreement within a structured diagnostic algorithm in a high-throughput screening setting. Differences in assay performance were observed across platforms, particularly with respect to discordant results in the ARCHITECT-reactive PCR-evaluated subset for HIV and non-treponemal concordance for syphilis. These platforms may support more efficient laboratory workflows; however, findings should be interpreted within the context of comparator-based classification rather than absolute diagnostic accuracy.