Thanh Nguyen

Dr. Thanh Nguyen

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
TNThanh Nguyen
Thanh Nguyen
KDKofi Deh
Kofi Deh
EMElizabeth Monohan
Elizabeth Monohan
SPSneha Pandya
Sneha Pandya
PSPascal Spincemaille
Pascal Spincemaille
SGSusan A. Gauthier
Susan A. Gauthier

6 June 2022 in Journal of Neuroimaging
Verified
Journal Article
Closed access
ADAlexey V. Dimov
Alexey V. Dimov
TNThanh Nguyen
Thanh Nguyen
KGKelly M. Gillen
Kelly M. Gillen
MMMelanie Marcille
Melanie Marcille
PSPascal Spincemaille
Pascal Spincemaille
YWYi Wang
Yi Wang

3 January 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TNThanh Nguyen
Thanh Nguyen
CWCynthia Wisnieff
Cynthia Wisnieff
MCMitchell A. Cooper
Mitchell A. Cooper
DKDushyant Kumar
Dushyant Kumar
ARAshish Raj
Ashish Raj
SGSusan A. Gauthier
Susan A. Gauthier
Quantitative assessment of myelination is important for characterizing tissue damage and evaluating response to therapy in white matter diseases such as multiple sclerosis. Conventional multicomponent T2 relaxometry based on the two‐dimensional (2D) multiecho spin echo sequence is a promising method to measure myelin water fraction, but its clinical utility is impeded by the prohibitively long data acquisition and limited brain coverage. The objective of this study was to develop a signal‐to‐noise ratio efficient 3D T2prep spiral gradient echo (3D SPIRAL) sequence for full brain T2 relaxometry and to validate this sequence using 3D multiecho spin echo as reference standard in healthy brains at 1.5 T. 3D SPIRAL was found to provide similar myelin water fraction in six selected white and gray matter areas using region‐of‐interest signal averaging analysis (N = 7, P > 0.05). While 3D multiecho spin echo only provided partial brain coverage, 3D SPIRAL enabled whole brain coverage with a fivefold higher acquisition speed per imaging slice and similar signal‐to‐noise ratio efficiency. Both 3D sequences provided superior signal‐to‐noise ratio efficiency when compared to the conventional 2D multiecho spin echo approach. Magn Reson Med, 2012.

14 December 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
YYY. Yao
Y. Yao
TNThanh Nguyen
Thanh Nguyen
SPS. Pandya
S. Pandya
YZY. Zhang
Y. Zhang
SRS. Hurtado Rúa
S. Hurtado Rúa
SGS.A. Gauthier
S.A. Gauthier
BACKGROUND AND PURPOSE: A hyperintense rim on susceptibility in chronic MS lesions is consistent with iron deposition, and the purpose of this study was to quantify iron-related myelin damage within these lesions as compared with those without rim. MATERIALS AND METHODS: Forty-six patients had 2 longitudinal quantitative susceptibility mapping with automatic zero reference scans with a mean interval of 28.9 ± 11.4 months. Myelin water fraction mapping by using fast acquisition with spiral trajectory and T2 prep was obtained at the second time point to measure myelin damage. Mixed-effects models were used to assess lesion quantitative susceptibility mapping and myelin water fraction values. RESULTS: Quantitative susceptibility mapping scans were on average 6.8 parts per billion higher in 116 rim-positive lesions compared with 441 rim-negative lesions (P < .001). All rim-positive lesions retained a hyperintense rim over time, with increasing quantitative susceptibility mapping values of both the rim and core regions (P < .001). Quantitative susceptibility mapping scans and myelin water fraction in rim-positive lesions decreased from rim to core, which is consistent with rim iron deposition. Whole lesion myelin water fractions for rim-positive and rim-negative lesions were 0.055 ± 0.07 and 0.066 ± 0.04, respectively. In the mixed-effects model, rim-positive lesions had on average 0.01 lower myelin water fraction compared with rim-negative lesions (P < .001). The volume of the rim at the initial quantitative susceptibility mapping scan was negatively associated with follow-up myelin water fraction (P < .01). CONCLUSIONS: Quantitative susceptibility mapping rim-positive lesions maintained a hyperintense rim, increased in susceptibility, and had more myelin damage compared with rim-negative lesions. Our results are consistent with the identification of chronic active MS lesions and may provide a target for therapeutic interventions to reduce myelin damage.

28 October 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
TNThanh Nguyen
Thanh Nguyen
LRLudovic de Rochefort
Ludovic de Rochefort
PSPascal Spincemaille
Pascal Spincemaille
MCMatthew D. Cham
Matthew D. Cham
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
YWYi Wang
Yi Wang
Purpose: To investigate the effectiveness of flow signal suppression of a motion‐sensitizing magnetization preparation (MSPREP) sequence and to optimize a 2D MSPREP steady‐state free precession (SSFP) sequence for black blood imaging of the heart.Materials and Methods: Using a flow phantom, the effect of varying field of speed (FOS), b‐value, voxel size, and flow pattern on the flow suppression was investigated. In seven healthy volunteers, black blood images of the heart were obtained at 1.5T with MSPREP‐SSFP and double inversion recovery fast spin echo (DIR‐FSE) techniques. Myocardium and blood signal‐to‐noise ratio (SNR) and myocardium‐to‐blood contrast‐to‐noise ratio (CNR) were measured. The optimal FOS that maximized the CNR for MSPREP‐SSFP was determined.Results: Phantom data demonstrated that the flow suppression was induced primarily by the velocity encoding effect. In humans, FOS = 10–20 cm/s was found to maximize the CNR for short‐axis (SA) and four‐chamber (4C) views. Compared to DIR‐FSE, MSPREP‐SSFP provided similar blood SNR efficiency in the SA basal and mid‐views and significantly lower blood SNR efficiency in the SA apical (P = 0.02) and 4C (P = 0.01) views, indicating similar or better blood suppression.Conclusion: Velocity encoding is the primary flow suppression mechanism of the MSPREP sequence and 2D MSPREP‐SSFP black blood imaging of the heart is feasible in healthy subjects. J. Magn. Reson. Imaging 2008;28:1092–1100.

26 February 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
TNThanh Nguyen
Thanh Nguyen
PSPascal Spincemaille
Pascal Spincemaille
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
BHBernard Y. Ho
Bernard Y. Ho
MCMatthew D. Cham
Matthew D. Cham
YWYi Wang
Yi Wang
Purpose: To develop a rapid navigator‐gated three‐dimensional (3DNAV) delayed‐enhancement MRI (DE‐MRI) sequence for myocardial viability assessment, and to evaluate its performance with breathhold two‐dimensional (2DBH) DE‐MRI sequence as the reference standard.Materials and Methods: 2DBH DE‐MRI was initiated 10 minutes after contrast administration and followed by 3DNAV DE‐MRI in 23 patients at 1.5 T. Comparison was performed using three qualitative criteria (image quality score, diagnostic outcome, relative diagnostic confidence score) in all patients, and three quantitative criteria (infarct volume, infarct signal‐to‐noise ratio [SNRinf], and infarct‐viable myocardium contrast‐to‐noise ratio [CNRinf‐myo]) in patients with hyperenhanced myocardium.Results: Compared to 2DBH DE‐MRI, 3DNAV DE‐MRI provided slightly better image quality, the same final diagnostic outcomes, and better relative diagnostic confidence score with 79% SNRinf improvement (P = 0.002) and 90% CNRinf‐myo improvement (P = 0.004) in 39% less scan time (414 ± 118 seconds for 2DBH and 251 ± 93 seconds for 3DNAV). The measured infarct volumes demonstrated excellent correlation (18.9 ± 19.0 mL for 2DBH DE‐MRI vs. 17.6 ± 19.0 mL for 3DNAV DE‐MRI, r2 = 0.998, P < 0.001, N = 7) and narrow limits of agreement (–1.3 ± 1.8 mL).Conclusion: 3DNAV DE‐MRI provides improved image quality and similar infarct detection in less scan time compared to the standard 2DBH DE‐MRI. J. Magn. Reson. Imaging 2008.