The effects of dimensionless parameters and boundary friction on air-entraining vortices and the critical submergence of an intake located in no-circulation imposed cross-flow and still water are investigated. It is found that limit values affect these vortices and the critical submergence, depending on the flow and geometrical conditions. The slower the cross-flow is, the higher these limit values are. The boundary friction effects on air-entraining vortices at intakes located in both a cross-flow and still water are also examined. The boundary section close to the free surface has a much larger effect than the boundary section away from it. The frictional effect of a boundary section on an air-entraining vortex depends on the distance between the boundary and the vortex centre at the free surface (above the intake centre). The boundary has maximum frictional effect if it is located at the vortex centre.
Both the profile and orientation of an intake entrance basically determine the characteristics of the flow (especially the velocity distribution and therefore the hydraulically developed subsurface depressions) toward the intake. The profile and orientation of the intake affect (1) the process of accumulation and growth of vorticity (circulation) along the pathway axis of the swirling vortex from the free surface to the intake; (2) position of the pathway of the swirling-vortex filament; and (3) location of the point of entry of the free-surface or subsurface vortex at the entrance of the intake. Test results indicate that the intake-entrance profile has limited effects on the occurrence of the air-core vortex and critical submergence. Regardless of the profile of the intake entrance, one common physical mechanism exists for development of free vortices occurring at intake entrances of different profiles. It is proven that spherical sink surface sectors (SSSSs) are essential for the vortex to exist.
The present study highlights the need for using both the kinematic and dynamic similarities in scaled models of the critical submergence of vertical vortices at intake structures. A semi-theoretical approach, which is based on the principle of flow continuity, is used in combination with published experimental data. The present study shows that only the kinematic similarity is needed to model the ratio of the critical submergence to the diameter of the intake. For intakes that have an identical ratio of the intake velocity to the velocity at the critical spherical sink surface (CSSS), the ratio of the critical submergence to the diameter of the intake is identical regardless of the flow and the geometrical conditions. The new finding is that dynamic similarity is not required for the prediction of the ratio of the critical submergence to the intake diameter, provided that the ratio of the intake velocity to the velocity at the CSSS is kept the same.
The critical submergence for dual rectangular intakes with no partition walls was investigated. To predict this critical submergence, the same principles as the available superposition methods developed for multiple pipe intakes were followed. Experiments were conducted on dual rectangular intakes located in different relative positions in an incoming developed canal flow. Multiple (dual) intakes introduce flow blockages on one another’s flow. A flow blockage is a type of extra outflow (intake flow) for sink surfaces in addition to the flow of the intake. Because of such an additional suction flow, it is as if the discharge of the intake is increased. Because dual intakes introduce mutual flow blockages and cause more disturbances, the critical submergence is increased. Agreement between the theoretical and experimental results was satisfactory. Depending on the flow and geometrical conditions, the correlation coefficients between the experimental and theoretical results vary from 0.61–0.90.
9 March 2016 in Arabian Journal for Science and Engineering
The effects of dimensions and relative positions of two (a dual) pipe intakes on the critical submergence are investigated. A dimensional analysis provided the relationship between the critical submergence and the governing dimensionless variables. Also, the potential flow solution was utilized to predict the critical submergence(s) for dual pipe intakes without partition walls located in the canal axis. Experiments were conducted on two vertical intakes at various relative positions. The experimental results indicate that the critical submergence is considerably affected by the relative positions and dimensions of an intake. The critical submergence for dual pipe intakes is larger than that of a single intake under identical conditions. The agreement between the potential flow solution and the experimental data related to the dual intakes on the same axis as the canal flow was found to be good.