Hip resurfacing arthroplasty (HRA) preserves femoral bone and was widely adopted for young, active patients with hip osteoarthritis before the decline of large-diameter metal-on-metal (MoM) bearings, which was driven by adverse reactions to metal debris (ARMD) and raised cobalt and chromium levels. New bearing couples, notably ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP), together with lessons learned from registries, have renewed interest in the procedure. This narrative review summarizes the historical evolution of HRA, current indications and contraindications, the learning curve, and the documented biomechanical and functional advantages (bone preservation, sta-bility, return to sport, gait), and compares contemporary implants using registry and published data. Long-term registry data support selected MoM implants only in men with large femoral heads (Birmingham Hip Resurfacing: 88.5% survival at 20 years; ADEPT: 94.1% at 15 years). The CoC ReCerf (MatOrtho) shows 5-year survival of 98.0–99.6% irrespective of sex and head size, but follow-up is short (mean 4 years) and evidence is limited to level III–IV. Data on cementless CoC H1 (Zimmer) and metal-on-polyethylene designs remain preliminary. HRA should be restricted to experienced surgeons in high-volume centres, with rigorous patient selection. Long-term registry surveillance and prospective comparative studies, including comparisons with short-stem and dual-mobility total hip arthroplasty, are needed.
Revision total knee arthroplasty (rTKA) is a technically demanding procedure that fre-quently relies on stems, augments, metaphyseal cones and constrained implants to restore knee alignment and stability. In carefully selected cases with preserved metaphyseal bone stock and competent collateral ligaments, robotic assistance allows a bone-preserving strategy in which alignment, joint line height, and soft-tissue balance are restored using conventional posterior-stabilized components with short cemented stems rather than higher invasive and constrained constructs. This technical note describes a step-by-step surgical workflow using the Mako robotic system (Stryker) to revise failed primary TKA associated with minimal metaphyseal bone loss to rTKA with conventional posterior-stabilized components with short cemented stems within a functional-alignment framework. The workflow integrates CT-based three-dimensional planning, registration on in situ implants, real-time gap assessment, and precise robotic bone preparation to correct deformity and to restore stability while minimizing additional bone resection. In this setting, limited tibial metaphyseal defects are managed with impacted autologous cancellous graft, and stable fixation is achieved with short cemented stems. This reproducible robotic-assisted approach is intended as a bone-preserving option for selected rTKA cases associated with minimal bone loss and as a conceptual bridge between robotic-assisted primary and conventional revision TKA performed with mechanical technique and alignment.
Background: Revision total knee arthroplasty (rTKA) is a technically demanding procedure that, when performed using mechanically aligned strategies, frequently relies on stems, augments, metaphyseal cones and constrained implants to restore knee alignment and stability. In carefully selected cases with preserved metaphyseal bone stock and competent collateral ligaments, robotic assistance allows a bone-preserving strategy in which alignment, joint line height, and soft-tissue balance are restored using conventional posterior-stabilized components with short cemented stems rather than higher invasive and constrained constructs. Methods: This technical note describes a step-by-step surgical workflow using the Mako robotic system (Stryker) to revise failed primary TKA associated with minimal metaphyseal bone loss to rTKA with conventional posterior-stabilized components and short cemented stems within a functional alignment framework. Results: The workflow integrates CT-based three-dimensional planning, registration on in situ implants, real-time gap assessment, and precise robotic bone preparation to correct deformity and to restore stability while minimizing additional bone resection. In this setting, limited tibial metaphyseal defects are managed with impacted autologous cancellous graft, and stable fixation is achieved with short cemented stems. Conclusions: This robotic-assisted approach is intended as a bone-preserving option for selected rTKA cases associated with minimal bone loss and as a conceptual bridge between robotic-assisted primary and conventional revision TKAs performed with mechanical techniques and alignments.
Purpose: Long stems with diaphyseal fixation are widely used in revision total hip arthroplasty (RTHA) but may increase surgical complexity and compromise femoral bone stock. Primary femoral stems, used as a de-escalation strategy, could simplify RTHA in selected patients as a bone preserving strategy. This study aimed to evaluate the clinical and radiographic outcomes of this technique using a cementless rectangular-taper shortened stem during both components RTHA. Methods: Between January 2019 and January 2025, 301 both components RTHA were prospectively included in our institutional total joint registry. Among them, 23 RTHA (20 patients, 14 men, mean age at revision = 63 years [54–71]) with femoral de-escalation with the use of a cementless rectangular-taper shortened stem and a dual mobility cup construct were identified and retrospectively reviewed at latest follow-up, focusing on complications related to this reconstruction technique. Clinical outcome was evaluated with the Harris Hip Score (HHS). Results: At a mean follow-up of 48 months (23–75), no postoperative periprosthetic fracture, mechanical failure or early loosening of the femoral reconstruction occurred. One early dislocation occurred at 41 days, managed by closed reduction without recurrence at latest follow-up. The mean HHS significantly improved from 70 (59–83) preoperatively to 94 (64–100) postoperatively, with 96% of patients achieving HHS ≥ 80 at latest follow-up. Conclusions: In selected patients undergoing RTHA with limited femoral bone loss, femoral de-escalation with a cementless rectangular-taper shortened stem demonstrated reliability for femoral reconstruction with no component-related complication and significant functional improvement at short-term follow-up.