The aim of this study is to compare the accuracy of Airgo™, a non-invasive wearable device that records breath, with respect to a gold standard. In 21 healthy subjects (10 males, 11 females), four parameters were recorded for four min at rest and in different positions simultaneously by Airgo™ and SensorMedics 2900 metabolic cart. Then, a cardio-pulmonary exercise test was performed using the Erg 800S cycle ergometer in order to test Airgo™’s accuracy during physical effort. The results reveal that the relative error median percentage of respiratory rate was of 0% for all positions at rest and for different exercise intensities, with interquartile ranges between 3.5 (standing position) and 22.4 (low-intensity exercise) breaths per minute. During exercise, normalized amplitude and ventilation relative error medians highlighted the presence of an error proportional to the volume to be estimated. For increasing intensity levels of exercise, Airgo™’s estimate tended to underestimate the values of the gold standard instrument. In conclusion, the Airgo™ device provides good accuracy and precision in the estimate of respiratory rate (especially at rest), an acceptable estimate of tidal volume and minute ventilation at rest and an underestimation for increasing volumes.
1 January 2017 in World Journal of Transplantation
To systematically review reports on deceased-donor-lobar lung transplantation (ddLLTx) and uniformly describe size matching using the donor-to-recipient predicted-total lung-capacity (pTLC) ratio. We set out to systematically review reports on ddLLTx and uniformly describe size matching using the donor-to-recipient pTLC ratio and to summarize reported one-year survival data of ddLLTx and conventional-LTx. We searched in PubMed, CINAHL via EBSCO, Cochrane Database of Systematic Reviews via Wiley (CDSR), Database of Abstracts of Reviews of Effects via Wiley (DARE), Cochrane Central Register of Controlled Trials via Wiley (CENTRAL), Scopus (which includes EMBASE abstracts), and Web of Science for original reports on ddLLTx. Nine observational cohort studies reporting on 301 ddLLTx met our inclusion criteria for systematic review of size matching, and eight for describing one-year-survival. The ddLLTx-group was often characterized by high acuity; however there was heterogeneity in transplant indications and pre-operative characteristics between studies. Data to calculate the pTLC ratio was available for 242 ddLLTx (80%). The mean pTLCratio before lobar resection was 1.25 ± 0.3 and the transplanted pTLCratio after lobar resection was 0.76 ± 0.2. One-year survival in the ddLLTx-group ranged from 50%-100%, compared to 72%-88% in the conventional-LTx group. In the largest study ddLLTx (n = 138) was associated with a lower one-year-survival compared to conventional-LTx (n = 539) (65.1% vs 84.1%, P < 0.001). Further investigations of optimal donor-to-recipient size matching parameters for ddLLTx could improve outcomes of this important surgical option.
26 October 2017 in The Clinical Respiratory Journal