An efficient solid phase extractive preconcentration/separation method was developed for the trace determination of herbicides in aqueous samples using Amberlite XAD-4 resin as the adsorbent. The retained herbicides were eluted with methanol at a flow rate of 1.0 mL min−1 and determined by HPLC-DAD (wavelength of 220 nm) using water (pH:4.7, phosphoric acid) and methanol (ratio 35:65) as the mobile phase with a flow rate of 1.0 mL min−1. Quantitative recoveries of simazine, atrazine and its metabolities were achieved at optimized analysis conditions that included 0.75 g of resin; a pH of 3.0; an eluent volume of 3.0 mL; an eluent flow rate of 1.0 mL min−1; and a sample flow rate of 4.0 mL min−1. The limits of detection, preconcentration factor, and linear ranges for the herbicides were 0.084–0.121 µgL−1, 1000, and 0.5–20 mg L−1, respectively. The performance of the method was evaluated by analysis of spiked water samples. The recoveries of simazine, atrazine and their metabolities were found to be quantitative (99.6–104.8%) with RSDs of 2.2–4.8% and 2.8–4.7% for intra-day and inter-day precision, respectively. The proposed method was successfully applied for trace determination of studied analytes in waste water, apple juice, and red wine samples.
Background: fipronil, a widely utilized insecticide in agriculture, has been shown to have potential health implications as it can accumulate in the environment and affect human health.
This study presents the separation and recovery of boron from geothermal waters with a polymeric membrane system and suggests a transport mechanism. The optimum relative parameters of the transport were examined. The recovery value of boron was 60.46% by using polymeric membrane system from prepared aquatic solution to the acceptor phase. The membrane’s capacity and selectivity of the transport process were examined. Kinetics values were calculated for each transport parameter. The optimum kinetic values were 1.4785 × 10−6 (s−1), 7.3273 × 10−8 (m/s), 13.5691 × 10−8 (mol/m2.s), 5.8174 × 10−12 (m2/s) for constant rate, permeability coefficient, flux, and diffusion coefficient, respectively. Boron was transported selectively and successfully from geothermal waters in the presence of other metal cations with 59.85% recovery value. This study indicates the application of real samples in polymeric membrane systems, which are very practical, economic, and easy to use for large-scale applications. The chemical and physical properties of polymer inclusion membranes (PIMs) offer the opportunity to be specially designed for specific applications.
9 January 2020 in Food Additives & Contaminants: Part A
Polycyclic aromatic hydrocarbons (PAHs) are ingested with foods and cause toxicities for humans. Yoghurt is one of the main foods that mediate PAH ingestion. Yanık yoghurt, a traditional strained yoghurt, can contain PAHs due to its production process. Therefore, the concentration and types of four polycyclic aromatic hydrocarbons were determined by gas chromatography-mass spectrometry (GC-MS). Yanık yoghurt samples were collected from different shops in Denizli, Turkey. For the method validation, the Eurachem guide (second edition) was adopted. Accordingly, linearity, working range, limits of detection (LOD), quantification (LOQ), precision and trueness values were set. Due to the selected validation parameters, the limit for detection was between 0.03 ng g−1and 0.05 ng g−1while the limit for quantification was between 0.10 ng g−1 and 0.16 ng g−1. Recovery rates higher than 83.80 % were obtained for four PAHs at two spiked concentrations (2.0 and 5.0 ng g−1). Five Yanık yoghurt samples and one commercial concentrated yoghurt sample were successfully analysed using the validated method.
This paper presents a simple, relatively inexpensive method for the detection of a group of commonly used herbicides such as mesotrione, simazine and atrazine in vegetables, thermal water and sediment samples by means of reversed phase-high performance liquid chromatography (RP-HPLC) with ultraviolet detection (DAD). The calibration curves were linear in the concentration range of 0.10-5.00 μg/mL. The limits of detection calculated at a signal-to-noise ratio of 3 were in the range of 0.03-0.10 μg/mL. The uncertainties of analytical methods were lower than 10 %. The method was validated by spiking recovery test of mesotrione, simazine and atrazine from the samples. Simazine and atrazine in the concentration range of 0.03-0.82 μg/g were detected in most of the vegetable samples, whereas mesotrione in the concentration of 2.40 and 4.96 μg/ mL was found only in thermal waters and 0.28 μg/g in a sediment sample.
24 November 2020 in International Journal of Environmental Analytical Chemistry
The current study portrays a dispersive solid-phase extraction as a silica nanoparticle-covered Graphene Oxide(GO-SiO2) synthesised with some modification as in the literature and developed removal/preconcentration method for selective extraction of some heavy metal in water samples. Flame atomic absorption spectrophotometry (FAAS) was used to measure in optimum conditions for the proposed method. Field emission scanning electron microscope (FESEM) and X-beam diffraction (XRD) were utilised for the characterisation of solid phase. The developed method presents high surface areas for sorption capacity and a low amount of solid phase. The removal percentage was performed at approximately 100% with pH 4 to 10 for all metal ions. According to validation results under the optimised method, the limits of detection (LODs) and quantification (LOQs) were found in the range of 5.8–23.0 µg L−1 and 16.0 − 38.1 µg L−1, respectively. The developed method was applied by using certified reference material (BCR 715) for trueness, which observed high relative recovery with lower than 11.8% relative error except for Pb and Cd. The comparison between the experimental results and the certified reference material indicated that the accuracy of the method is higher than 90%. The proposed method was effectively practised for five water samples with standard addition.