While the Italian standard UNI 11235:2015 establishes minimum performance criteria, the thermal resistance of the growing medium of green roofs is not included in national regulations. Instead, thermal transmittance limits for roofs are obtained by referring to other stratigraphic layers. In the absence of specific national and international standards for laboratory calculations of the thermal performance of growing media for green roofs, a multi-year laboratory testing campaign was carried out on 8 samples which aimed to define the thermal resistance reference values of growing media as a function of density and water content. Thermal conductivity varies between 0.046–0.179 W/mK for dry samples as a function of density and between 0.046–0.47 W/mK as a function of moisture content. Defining a reference method, laboratory tests and restitution of the output in performance curves, was based on 108 tests carried out according to and deviating from the standard based on both guarded hot plate and heat flow meter methods. The significance of the results has prompted researchers and industrial partners to engage in further investment and ongoing tests in this area, targeting the definition of a standard laboratory method to be presented worldwide.
Green roofs are one of the most extensively investigated roofing technologies. Most of the bibliographical studies show results of researches focused on the analysis of different configurations of green roofs, but only few researches deal with the calculation of the growing media thermal resistance using laboratory tests. From 2009 to 2013, ITC-CNR, the Construction Technologies Institute of the National Research Council of Italy, carried out a first laboratory experimental campaign focused on the definition of thermal performances curves of growing media for green roofs as a function of both density and percentage of internal moisture. During this campaign, the experimental results underlined some existing gaps, such as the absence of specific standards concerning the sample laboratory preparation, the absence of shared references concerning the compaction level reached by samples in real working conditions and the evaluation of the internal moisture content of growing media exposed to atmospheric agents. For this reason, the ITC-CNR has set up a second experimental campaign focused on the solution of the gaps underlined by the first phase concerning the preparation of samples for the laboratory calculation of the thermal resistance of growing media for green roofs. This paper proposes and presents methodological approaches, methods and new test devices implemented to solve these gaps, and the results obtained.
The preservation of cultural heritage within museum environments requires systematic control and monitoring of indoor microclimatic conditions. Over the past four decades, scientific evidence has established the critical role of environmental parameters, including air temperature, relative humidity, light, and airborne pollutants, in the preventive conservation of artifacts. International standards and national guidelines mandate continuous, non-invasive monitoring protocols that integrate conservation requirements with the architectural and operational constraints of historic buildings. Effective implementation necessitates a multidisciplinary approach balancing artifact preservation, human comfort, and building energy efficiency. Recent international recommendations further promote adaptive approaches wherein microclimate thresholds are calibrated to site-specific “historical climate” conditions, derived from minimum one-year baseline datasets. While essential for long-term conservation management, the design and implementation of such monitoring systems present significant technical and logistical challenges. This study presents a replicable methodological approach wherein preliminary surveys and three short-term monitoring campaigns (duration: 2 to 5 weeks) supported design, sensor selection, and spatial deployment and will allow the validation of a long-term continuous monitoring infrastructure (at least one year). These preliminary investigations enabled the following: (1) identification of priority environmental parameters; (2) optimization of sensor placement relative to exhibition layouts and maintenance protocols; and (3) preliminary assessment of microclimate risks in naturally ventilated spaces in the absence of HVAC systems.