This paper presents an investigation of effects of high voltage direct current (HVDC) superimposed voltage harmonics on partial discharge (PD) behavior. Firstly, a single air filled void embedded in a slab of polymeric insulation was modeled using finite element methods (FEM). PD phenomena activated under the influence of rippled DC voltages were simulated using an interlinked environment of MATLAB and multiphysics simulation package COMSOL. Secondly, the results of the modeling were backed up by experimental tests, where HVDC superimposed harmonics were applied to artificial void samples in the lab and trends in the resultant PD characterized with varying harmonic orders and amplitudes. The results of both modeling and experiment are generally in agreement showing that as the harmonic orders and levels increase, the repetition rate of PD pulses rises in comparison to a purely DC applied voltage having the same peak amplitude. The findings of this study will assist in understanding of PD behavior under HVDC conditions where harmonic rippling occurs on the voltage waveform.
29 June 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Power cables undergo various types of overstressing conditions during their operation that influence the integrity of their insulation systems. This causes accelerated ageing and might lead to their premature failure in severe cases. This paper presents an investigation of the impacts of various dynamic electric fields produced by ripples, polarity reversal and transient switching impulses on partial discharge (PD) activity within solid dielectrics with the aim of considering such phenomena in high voltage direct current (HVDC) cable systems. Appropriate terminal voltages of a generic HVDC converter were reproduced — with different harmonic contaminations — and applied to the test samples. The effects of systematic operational polarity reversal and superimposed switching impulses with the possibility of transient polarity reversal were also studied in this investigation. The experimental results show that the PD is greatly affected by the dynamic changes of electric field represented by polarity reversal, ripples and switching. The findings of this study will assist in understanding the behaviour of PDs under HVDC conditions and would be of interest to asset managers considering the effects of such conditions on the insulation diagnostics.
Electrical treeing (ET) can irreversibly deteriorate the insulation of polymeric power cables leading to a complete failure. This paper presents the results of an experimental investigation into the effects of unipolar and polarity reversing DC voltages on electrical tree (ET) and partial discharge (PD) behavior within high voltage direct current (HVDC) cross linked polyethylene (XLPE) cable insulation. A double needle configuration was adopted to produce non-uniform electric fields within the insulation samples, potentially leading to electrical trees. The development of trees was monitored through an optical method and the associated partial discharge signals were measured through an electrical detection technique, simultaneously. The analysis of the results shows reasonable relation between the formation of ETs and the type of the applied voltages. The polarity reversing attribute of the test voltages has a pronounced effect on formation and growth of electrical trees. This implicates an interaction between the space charges that accumulate within polymeric materials and the operational polarity reversing electric fields, which causes insulation degradation. Therefore, study of influencing HVDC operational parameters on insulation degradations can contribute to improvements in cable design and advancement in insulation diagnostic strategies applicable in HVDC systems leading to more effective asset management.
Insulation degradation is an irreversible phenomenon that can potentially lead to failure of power cable systems. This paper describes the results of an experimental investigation into the influence of direct current (DC) superimposed with harmonic voltages on both partial discharge (PD) activity and electrical tree (ET) phenomena within polymeric insulations. The test samples were prepared from a high voltage direct current (HVDC) cross linked polyethylene (XLPE) power cable. A double electrode arrangement was employed to produce divergent electric fields within the test samples that could possibly result in formation of electrical trees. The developed ETs were observed via an optical method and, at the same time, the emanating PD pulses were measured using conventional techniques. The results show a tenable relation between ETs, PD activities, and the level of harmonic voltages. An increase in harmonic levels has a marked effect on development of electrical trees as the firing angle increases, which also leads to higher activity of partial discharges. This study of the influencing operational parameters of HVDC converters on power cable insulation is predicted to contribute to enhancements in cable design and progressive advancement in condition monitoring and insulation diagnostic techniques that can lead to more effective asset management in HVDC systems.
Insulation is a critical component of any electrical power system, which, when subjected to excessive stress, may lead to premature ageing and eventual failure. Partial discharge (PD) measurement is a well-developed insulation diagnostic method, particularly under alternating voltage (AC), for quality assessment and condition monitoring of power apparatus. However, this technique is still immature when applied to DC operating equipment, especially high voltage direct current (HVDC) systems where rippled and distorted voltage waveforms appear at the output terminal of the converters. This paper presents the results of experimental PD measurements and analysis for commonly encountered PD sources: corona, surface and void discharging defects under the application of DC and DC superimposed with harmonics. The results show that PD activity under rippled voltage is different than that under pure DC. PD occurs with higher repetition rate, and is - in varying degrees - influenced by the relative magnitudes of the harmonics, depending on the PD source. Since it appears that PD is more severe under the influence of harmonic voltage ripple, the results should be of interest to network operators and will contribute to understanding of the phenomena in HVDC insulation diagnostics.
1 February 2013 in Journal of Fuel Cell Science and Technology
Here, a hybrid vehicle structure comprising fuel cell/battery and a PMDC electrical machine has been proposed, in which an intelligent controller is to perform power management and regenerative braking tasks. Instead of a gasoline engine, an electric machine fulfills the power demand from the vehicle during driving and braking modes. In addition, regenerative braking is possible in the proposed structure. The fuel cell is connected to a battery (DC bus) via a DC/DC converter which can control the fuel cell power/current with a switching strategy. A Nero–Fuzzy controller has been devised in order for taking the power demand as one of its controlling signals and making decision with respect to the power management issue. Duty cycle of the DC/DC converter is computed by the driving controller and applied with a certain switching frequency. Along with the power demand, braking pedal displacement, and the battery state of charge act as controlling signals, which allow the power management controller to perform pertinent analysis for power sharing decision between both the power sources. A threshold zone has been considered for braking pedal, according to which a regenerative torque is produced by the electrical machine. Finally, the simulation results have been considered from different point of views and evaluated, which shows a tenable achievement. Particularly, a series of driving maneuvers were applied to the vehicle, and the results show that the proposed structure has a promising performance as a civic automobile with zero emissions.