Luis Moreno-Navarro

Dr. Luis Moreno-Navarro

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2025 in Journal of Neurology
Verified
Journal Article
Open access
PDF file
LMLuis Moreno-Navarro
Luis Moreno-Navarro
SMSergio Mora-Diaz
Sergio Mora-Diaz
LRLourdes Ruiz-Escribano-Menchen
Lourdes Ruiz-Escribano-Menchen
ASAngel Sempere
Angel Sempere
Background The proposed 2024 McDonald criteria incorporate the kappa free light chain (KFLC) index as an additional biomarker in multiple sclerosis (MS) diagnosis. Emerging evidence suggests that a high KFLC index may relate to worse outcomes in people with MS (pwMS). This study had two main objectives: to evaluate the diagnostic performance of the KFLC index against the 2017 and proposed 2024 clinico-radiological McDonald criteria, and to explore its prognostic significance. Methods We performed a retrospective cohort study of adults with a first episode suggestive of MS (2019–2024). All underwent lumbar puncture with simultaneous determination of the KFLC index and oligoclonal bands (OCB). Results Among 150 participants, OCB showed sensitivities of 85.9% (2017) and 86.6% (2024) with specificities of 79.7% and 81.9%. A KFLC index cut-off of 12.0 yielded sensitivities of 87.5% (2017) and 88.1% (2024) with specificities of 79.2% and 81.4%, comparable to OCB. In pwMS, KFLC index ≥ 100 was associated with younger age (OR 1.53, p = 0.048), women (OR 1.53, p = 0.037), relapses (OR 2.30, p = 0.029) and new infratentorial or spinal cord (SC) lesions (OR 6.90, p = 0.003). In multivariable analysis, KFLC index ≥ 100 remained associated with new infratentorial or SC lesions (aOR 8.07, p = 0.019). Conclusion The KFLC index shows diagnostic utility comparable to OCB; however, it is an adjunctive biomarker that complements clinical and MRI findings and should not be used as a standalone diagnostic test. An elevated KFLC index was associated with short-term accrual of infratentorial or SC lesions; these exploratory findings require validation in larger, longer-term cohorts.

1 January 2024 in Revista De Neurologia
Verified
Journal Article
Open access
LMLuis Moreno-Navarro
Luis Moreno-Navarro
MLMònica Farrerons Llopart
Mònica Farrerons Llopart
NHNicolás López Hernández
Nicolás López Hernández
SCSarai Moliner Castellano
Sarai Moliner Castellano
MAMaría José Ballesteros Aparicio
María José Ballesteros Aparicio
LALuis Concepción Aramendía
Luis Concepción Aramendía
Introduction. Acute ischemic stroke is one of the leading global causes of morbidity and mortality. Mechanical thrombectomy has improved the functional prognosis of this condition; however, hemorrhagic transformation is a common complication. Spectral computed tomography (CT) imaging, as a neuroimaging control test, distinguishes contrast extravasation from hemorrhagic transformation due to the differential behavior of materials at dual energy levels. This distinction is valuable in its clinical therapeutic management. Material and methods. A single-center, observational, retrospective study was conducted in which the presence of various clinical, radiological, and therapeutic variables in patients with acute ischemic stroke treated with mechanical thrombectomy at our hospital between July 2022 and March 2023 was investigated using access to a dissociated database and medical records. Results. Out of 155 included patients, spectral cranial CT was performed in 63, and conventional cranial CT in 75. In the spectral CT group, 21 hyperdense images were detected, compared to 28 in the conventional CT group. In 42.8% of cases where hyperdensity was detected in the conventional CT group, it was not possible to distinguish between contrast extravasation and hemorrhagic transformation, in contrast to the 4.8% in the spectral CT group (p < 0.001). Conclusions. Spectral CT provides high diagnostic confidence to the radiologist in identifying the type of detected hyperdensity, thereby offering significant therapeutic confidence to the neurologist in early resuming anticoagulation therapy.

1 November 2025 in Neurointervention
Verified
Journal Article
Open access
PDF file
PRPablo Ros-Arlanzón
Pablo Ros-Arlanzón
DCDiego José Corona-García
Diego José Corona-García
MWManuel Dieter Warnken-Miralles
Manuel Dieter Warnken-Miralles
EGElisa Ginés-Murcia
Elisa Ginés-Murcia
LMLuis Moreno-Navarro
Luis Moreno-Navarro
NLNicolás López-Hernández
Nicolás López-Hernández
Purpose: Carotid web (CW) is an underrecognized cause of recurrent ischemic stroke in young patients with cryptogenic stroke, and its optimal management remains uncertain. This study aimed to determine the recurrence of ischemic events and the incidence of asymptomatic thrombus formation in CW, in order to optimize secondary prevention strategies.Materials and Methods: We conducted a retrospective analysis of patients diagnosed with CW at a comprehensive stroke center in Spain between January 2021 and December 2024. CW was identified via computed tomography angiography or digital subtraction angiography. We assessed stroke recurrence, asymptomatic thrombus formation, and secondary prevention strategies. Early duplex sonography was systematically performed during hospitalization to detect in-hospital re-thrombosis.Results: Among 23 patients with CW-related ischemic stroke, 2 (8.7%) experienced recurrent ipsilateral stroke. Notably 4 (17.4%) patients exhibited thrombus formation within the CW, 3 of them while still hospitalized, detected through early duplex sonography. These findings, which preceded any clinical recurrence, prompted timely anatomical correction via stenting or endarterectomy, with no further events observed. All patients with clinical or radiologic recurrence (n=6) underwent either carotid stenting (n=4) or endarterectomy (n=2), after which no further ischemic events were observed.Conclusion: CW carries a substantial risk of early thrombus formation and recurrent ischemic stroke. Routine early neurosonologic monitoring during hospitalization can detect in-hospital re-thrombosis and enable timely intervention with stenting or endarterectomy, which appears effective in preventing recurrence.

4 April 2025 in Multiple Sclerosis and Related Disorders
Verified
Journal Article
Closed access
LMLuis Moreno-Navarro
Luis Moreno-Navarro
MFMonica Farrerons-Llopart
Monica Farrerons-Llopart
SLSofia Lorenzo-Garcia
Sofia Lorenzo-Garcia
LRLourdes Ruiz-Escribano-Menchen
Lourdes Ruiz-Escribano-Menchen
ASAngel P. Sempere
Angel P. Sempere

15 June 2023 in Archivos de Bronconeumología
Verified
Journal Article
Closed access
MRMarta Gómez Román
Marta Gómez Román
MRMaria del Mar García Ródenas
Maria del Mar García Ródenas
LMLuis Moreno-Navarro
Luis Moreno-Navarro
SSSantos Asensio Sánchez
Santos Asensio Sánchez
ASAngel Sempere
Angel Sempere

24 June 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
VPVíctor Martínez Pozo
Víctor Martínez Pozo
David BarbadoDavid Barbado
David Barbado
CDCarmina Díaz-Marín
Carmina Díaz-Marín
JGJonatan García-Campos
Jonatan García-Campos
ABaa Blasco
aa Blasco
DSDiana Salas-Gómez
Diana Salas-Gómez
This systematic review examined the validity and reliability of wearable inertial sensor systems to quantify spatiotemporal gait parameters in post-stroke adults, a population in which gait asymmetry and altered motor control challenge accurate measurement. Sixteen studies involving 300 participants were included. Spatial parameters gait speed, cadence, and step/stride length showed consistently good-to-excellent agreement with reference systems (ICC 0.85–0.98; 95% LoA ±0.03–0.08 m/s for gait speed, ±4–10 steps/min for cadence, and ±3–8 cm for step/stride length) and high test–retest reliability. Temporal parameters demonstrated greater heterogeneity, with larger errors and lower concordance (ICC 0.40–0.85; LoA ±0.04–0.12 s), particularly for swing time (ICC 0.40–0.70; LoA up to ±0.15 s). Paretic-side measurements showed 10–20% lower concordance and 30–50% wider limits of agreement compared with the non-paretic side, although within-subject reliability remained moderate to high. No consistent influence of sensor number on measurement accuracy was observed. Overall, wearable inertial sensors provide robust estimates of spatial gait parameters, whereas temporal outcomes especially swing time remain limited due to challenges in gait event detection under stroke-related biomechanical alterations. These findings highlight the need for standardized protocols and improved algorithms to enhance comparability across studies and support broader clinical adoption.