Geert Geleijnse

Mr. Geert Geleijnse

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
GGGeert Geleijnse
Geert Geleijnse
BRBernd Rieger
Bernd Rieger
SignificanceFlexible endoscopes are essential for medical internal examinations. Digital endoscopes are connected to a video processor that can apply various operations to enhance the image. One of those operations is edge enhancement, which has a major impact on the perceived image quality by medical professionals. However, the specific methods and parameters of this operation are undisclosed and the arbitrary units to express the level of edge enhancement differ per video processor.AimObjectively quantify the level of edge enhancement from the recorded images alone, and measure the effect on sharpness and noise.ApproachEdge enhancement was studied in four types of flexible digital ear nose and throat endoscopes. Measurements were performed using slanted edges and gray patches. The level of edge enhancement was determined by subtracting the step response of an image without edge enhancement from images with selected settings of edge enhancement and measuring the resulting peak-to-peak differences. These values were then normalized by the step size. Sharpness was characterized by observing the normalized modulation transfer function (MTF) and computing the spatial frequency at 50% MTF. The noise was measured on the gray patches and computed as a weighted sum of variances from the luminance and two chrominance channels of the pixel values.ResultsThe measured levels were consistent with the level set via the user interface on the video processor and varied typically from 0 to 1.3. Both sharpness and noise increase with larger levels of edge enhancement with factors of 3 and 4 respectively.ConclusionsThe presented method overcomes the issue of vendors expressing the level of edge enhancement each differently in arbitrary units. This allows us to compare the effects, and we can start exploring the relationship with the subjectively perceived image quality by medical professionals to find substantiated optimal settings.

17 August 2023 in The Laryngoscope
Verified
Journal Article
Open access
GGGeert Geleijnse
Geert Geleijnse
LVL. L. Veder
L. L. Veder
MHM. M. Hakkesteegt
M. M. Hakkesteegt
HGH. H. W. de Gier
H. H. W. de Gier
BRB. Rieger
B. Rieger
RMR. M. Metselaar
R. M. Metselaar
Objectives: Digital endoscopes are connected to a video processor that applies various operations to process the image. One of those operations is edge enhancement that sharpens the image. The purpose of this study was to (1) quantify the level of edge enhancement, (2) measure the effect on sharpness and image noise, and (3) study the influence of edge enhancement on image quality perceived by ENT professionals.Methods: Three digital flexible endoscopic systems were included. The level of edge enhancement and the influence on sharpness and noise were measured in vitro, while systematically varying the levels of edge enhancement. In vivo images were captured at identical levels of one healthy larynx. Each series of in vivo images was presented to 39 ENT professionals according to a forced pairwise comparison test, to select the image with the best image quality for diagnostic purposes. The numbers of votes were converted to a psychometric scale of just noticeable differences (JND) according to the Thurstone V model.Results: The maximum level of edge enhancement varied per endoscopic system and ranged from 0.8 to 1.2. Edge enhancement increased sharpness and noise. Images with edge enhancement were unanimously preferred to images without edge enhancement. The quality difference with respect to zero edge enhancement reaches an optimum at levels between 0.7 and 0.9.Conclusion: Edge enhancement has a major impact on sharpness, noise, and the resulting perceived image quality. We conclude that ENT professionals benefit from this video processing and should verify if their equipment is optimally configured.Level of Evidence: NA Laryngoscope, 134:842–847, 2024

30 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
BGBenjamin Gravesteijn
Benjamin Gravesteijn
EKEline Krijkamp
Eline Krijkamp
JBJan Busschbach
Jan Busschbach
GGGeert Geleijnse
Geert Geleijnse
IHIsabel Retel Helmrich
Isabel Retel Helmrich
Cornelis VerhoefCornelis Verhoef
Cornelis Verhoef
Background: COVID-19 has put unprecedented pressure on healthcare systems worldwide, leading to a reduction of the available healthcare capacity. Our objective was to develop a decision model that supports prioritization of care from a utilitarian perspective, which is to minimize population health loss. Methods: A cohort state-transition model was developed and applied to 43 semi-elective non-paediatric surgeries commonly performed in academic hospitals. Scenarios of delaying surgery from two weeks were compared with delaying up to one year, and no surgery at all. Model parameters were based on registries, scientific literature, and the World Health Organization global burden of disease study. For each surgery, the urgency was estimated as the average expected loss of Quality-Adjusted Life-Years (QALYs) per month. Results: Given the best available evidence, the two most urgent surgeries were bypass surgery for Fontaine III/IV peripheral arterial disease (0.23 QALY loss/month, 95%-CI: 0.09-0.24) and transaortic valve implantation (0.15 QALY loss/month, 95%-CI: 0.09-0.24). The two least urgent surgeries were placing a shunt for dialysis (0.01, 95%-CI: 0.005-0.01) and thyroid carcinoma resection (0.01, 95%-CI: 0.01-0.02): these surgeries were associated with a limited amount of health lost on the waiting list. Conclusion: Expected health loss due to surgical delay can be objectively calculated with our decision model based on best available evidence, which can guide prioritization of surgeries to minimize population health loss in times of scarcity. This tool should yet be placed in the context of different ethical perspectives and combined with capacity management tools to facilitate large-scale implementation. Summary box: What is already known on this topic: The perspective of maximizing population health, a utilitarian ethical perspective, has been described to be most defendable in times of scarcity. To prioritize surgical patients, literature mainly discusses approaches which are intra-disciplinary (e.g. within gynecological or oncological surgery) and mostly existed of narrative reviews of the literature. Some decision tools were developed, which rely on the consensus of experts on various measures of urgency (e.g. health benefit, or time until inoperable). No approach was found which transparently weighs objective factors in order to quantify a clinically relevant measure of urgency. What this study adds: In contrast to previously developed approaches, our approach transparently and consistently aggregates best available objective evidence across disciplines. This novel aggregated urgency measure can be easily linked with capacity management tools. Our approach can help to minimize health losses when trying to overcome delay in surgeries in times of surgical scarcity, during the COVID-19 pandemic and beyond.

1 July 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
GGGeert Geleijnse
Geert Geleijnse
BRBernd Rieger
Bernd Rieger
The erratum corrects a typo in Eq. (4) of the published article.

4 November 2026 in Hearing Research
Verified
Journal Article
Open access
SMSarah Meehan
Sarah Meehan
NHNick M.J. Hanenberg
Nick M.J. Hanenberg
NCNadia Van Crugten
Nadia Van Crugten
MAMarloes L. Adank
Marloes L. Adank
GGGeert Geleijnse
Geert Geleijnse
JVJantien L. Vroegop
Jantien L. Vroegop