Arnulfo Castro Vásquez

Dr. Arnulfo Castro Vásquez

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Información tecnológica
Verified
Journal Article
Closed access
PDF file
AVArnulfo Castro Vásquez
Arnulfo Castro Vásquez
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
SGSaúl González
Saúl González
LRLidia H Rascón
Lidia H Rascón
En este trabajo se presenta una metodología para el manejo de datos sobre información geográfica. La metodología se aplicó en la identificación de materiales de construcción de calles y avenidas de un área geográfica específica de Ciudad Juárez en México. Los datos necesarios para el desarrollo del modelo fueron obtenidos del Sistema de Información Geográfica de la Universidad Autónoma de Ciudad Juárez, los cuales incluyeron la intensidad y las coordenadas X,Y, Z de unos 878 mil registros de la ciudad. El desarrollo se realizó en varias etapas. La primera corresponde al pre-procesamiento y limpieza de los datos; la segunda es la formulación del modelo e incorporación de los datos a un gestor de base de datos; la tercera es el análisis mismo con técnicas de minería de datos utilizando el software Waika to Environment Knowledge Analysis (WEKA). Para la predicción se utilizaron los algoritmos k-means y Make Density Based Clusters. Los resultados fueron contrastados con imágenes satelitales de las zonas analizadas, validando así la metodología propuesta.

1 January 2016 in Información tecnológica
Verified
Journal Article
Open access
PDF file
FEFrancisco Enriquez
Francisco Enriquez
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
GBGabriel Bravo
Gabriel Bravo
AVArnulfo Castro Vásquez
Arnulfo Castro Vásquez
Se construyó un sistema de prueba semi-automatizado para auxiliar en las labores de préstamos de equipo del Laboratorio de Control en la Universidad Autónoma de Ciudad Juárez (México), específicamente de las tarjetas de adquisición de datos USB-6009 del fabricante National Instruments. Se diseñó un sistema para validar las entradas y salidas de esta tarjeta. El desarrollo se llevó a cabo utilizando una interfaz gráfica en LabVIEW y un punto de apoyo o base prototipo basada en un microcontrolador, que ayuda a corroborar su correcto o mal funcionamiento de la tarjeta cuando es prestada o cuando es retornada por el usuario al laboratorio. El diseño de la interfaz indica al usuario los periféricos que estén dañados y genera un reporte para llevar el control de las validaciones realizadas. De esta manera se tendrá un mejor control de préstamo de estas tarjetas de adquisición al momento de su entrega y devolución, beneficiando al laboratorio y al usuario.

18 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GBGabriel Bravo
Gabriel Bravo
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
GPGeu Misael Puentes
Geu Misael Puentes
FEFrancisco Enriquez
Francisco Enriquez
Cota RuizCota Ruiz
Cota Ruiz
AVArnulfo Castro Vásquez
Arnulfo Castro Vásquez
This work presents a time-domain analog-to-digital conversion method in which the amplitude of a sensor signal is encoded through its crossing instants with a periodic ramp. The proposed architecture departs from conventional ADC and PWM demodulation approaches by shifting quantization entirely to the time domain, enabling waveform reconstruction using only a ramp generator, an analog comparator, and a timer capture module. A theoretical framework is developed to formalize the voltage-to-time mapping, derive expressions for resolution and error, and identify conditions that ensure monotonicity and single-crossing behavior. Simulation results demonstrate high-fidelity reconstruction for both periodic and non-periodic signals, including real photoplethysmographic (PPG) waveforms, with errors approaching the theoretical quantization limit. A hardware implementation on a PSoC 5LP microcontroller confirms the practicality of the method under realistic operating conditions. Despite ramp nonlinearity, comparator delay, and sensor noise, the system achieves effective resolutions above 12 bits using only native mixed-signal peripherals and no conventional ADC. These results show that accurate waveform reconstruction can be obtained from purely temporal information, positioning time-encoded sensing as a viable alternative to traditional amplitude-based conversion. The minimal analog front end, low power consumption, and scalability of timer-based processing highlight the potential of the proposed approach for embedded instrumentation, distributed sensor nodes, and biomedical monitoring applications.

10 April 2024 in Nova Scientia
Verified
Journal Article
Open access
PDF file
AVArnulfo Castro Vásquez
Arnulfo Castro Vásquez
RGReyna García-Guadarrama
Reyna García-Guadarrama
MEMarco Tulio Gallo Estrada
Marco Tulio Gallo Estrada
This work describes the process of toxicity prediction of ionic liquids, specifically toxicity with respect to the IPC-81 rat cell line. We studied 355 molecular structures of ionic liquids, whose three-dimensional geometry is encoded by means of symbol strings such as Simplified Molecular Input Line Entry System (SMILES) language. The feeding of the input data to the different machine learning models requires that the geometrical and near atomic neighbor information of each ionic liquid be mapped or transformed to numerical vector notation (xi) using the following two molecular descriptors: Atom-Centered Symmetry Functions (ACSF), and Extended Connectivity Fingerprints (ECFP). Three machine learning algorithms: Extreme Gradient Boosting (XGBoost), Support Vector Regression (SVR) and Kernel Ridge Regression (KRR) were used to build the predictive mathematical regression model relating the input values xi to the response value represented by the logarithm of the mean effective concentration (yi = logEC50) in the toxicity assessment, using the coefficient of determination (r2) as a metric of the degree of fitness. The results obtained indicated that the ECFP combination with a radial distance of 6 atomic neighbors in conjunction with the KRR algorithm provides the best average fit with r2=0.8602±0.032, and with respect to the ACSF molecular descriptor the best average fit was obtained with the XGBoost algorithm with r2=0.8029±0.055. En este trabajo se describe el proceso de predicción de toxicidad de los líquidos iónicos, en particular con respecto a la línea celular en ratas IPC-81. Se estudiaron 355 estructuras moleculares de líquidos iónicos, cuya geometría tridimensional está codificada mediante cadenas de símbolos en lenguaje Simplified Molecular Input Line Entry System (SMILES). La alimentación de los datos de entrada a los diferentes modelos de aprendizaje máquina requiere que la información geométrica y de contactos atómicos cercanos de cada liquido iónico sea mapeada o trasformada a notación vectorial numérica (xi) utilizando los siguientes descriptores moleculares: funciones de simetría centradas en cada átomo Atom-Centered Symmetry Functions (ACSF), y huellas digitales de conectividad extendida Extended Connectivity Fingerprints (ECFP). Se usaron tres algoritmos de aprendizaje máquina: Extreme Gradient Boosting (XGBoost), Support Vector Regression (SVR) y Kernel Ridge Regression (KRR) para construir el modelo matemático de regresión predictivo que relacione los valores de entrada xi con el valor de respuesta representado por el logaritmo de la concentración media efectiva (yi = logEC50) en la evaluación de toxicidad, usando como métrica del grado de ajuste, el coeficiente de determinación (r2). Los resultados indican que la combinación ECFP, con una distancia radial de 6 vecinos atómicos, en conjunto con el algoritmo KRR, proporciona el mejor ajuste promedio con r2=0.8602±0.032, y con respecto al descriptor molecular ACSF, el mejor ajuste promedio se obtuvo con el algoritmo XGBoost con r2=0.8029±0.055.

18 January 2026 in Technologies
Verified
Journal Article
Open access
PDF file
GBGabriel Bravo
Gabriel Bravo
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
GPGeu Misael Puentes
Geu Misael Puentes
FEFrancisco Enriquez
Francisco Enriquez
Cota RuizCota Ruiz
Cota Ruiz
AVArnulfo Castro Vásquez
Arnulfo Castro Vásquez
This work presents a time-domain analog-to-digital conversion method in which the amplitude of a sensor signal is encoded through its crossing instants with a periodic ramp. The proposed architecture departs from conventional ADC and PWM demodulation approaches by shifting quantization entirely to the time domain, enabling waveform reconstruction using only a ramp generator, an analog comparator, and a timer capture module. A theoretical framework is developed to formalize the voltage-to-time mapping, derive expressions for resolution and error, and identify the conditions ensuring monotonicity and single-crossing behavior. Simulation results demonstrate high-fidelity reconstruction for both periodic and non-periodic signals, including real photoplethysmographic (PPG) waveforms, with errors approaching the theoretical quantization limit. A hardware implementation on a PSoC 5LP microcontroller confirms the practicality of the method under realistic operating conditions. Despite ramp nonlinearity, comparator delay, and sensor noise, the system achieves effective resolutions above 12 bits using only native mixed-signal peripherals and no conventional ADC. These results show that accurate waveform reconstruction can be obtained from purely temporal information, positioning time-encoded sensing as a viable alternative to traditional amplitude-based conversion. The minimal analog front end, low power consumption, and scalability of timer-based processing highlight the potential of the proposed approach for embedded instrumentation, distributed sensor nodes, and biomedical monitoring applications.