Laila Hubbert

Dr. Laila Hubbert

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Human Molecular Genetics
Verified
Journal Article
Open access
PDF file
CHCarola Hedberg-Oldfors
Carola Hedberg-Oldfors
AAAlexandra Abramsson
Alexandra Abramsson
DODaniel P S Osborn
Daniel P S Osborn
ODOlof Danielsson
Olof Danielsson
AFAfsoon Fazlinezhad
Afsoon Fazlinezhad
Yalda JamshidiYalda Jamshidi
Yalda Jamshidi
Hypertrophic cardiomyopathy (HCM) is the most common inherited cardiovascular disorder, yet the genetic cause of up to 50% of cases remains unknown. Here, we show that mutations in KLHL24 cause HCM in humans. Using genome-wide linkage analysis and exome sequencing, we identified homozygous mutations in KLHL24 in two consanguineous families with HCM. Of the 11 young affected adults identified, 3 died suddenly and 1 had a cardiac transplant due to heart failure. KLHL24 is a member of the Kelch-like protein family, which acts as substrate-specific adaptors to Cullin E3 ubiquitin ligases. Endomyocardial and skeletal muscle biopsies from affected individuals of both families demonstrated characteristic alterations, including accumulation of desmin intermediate filaments. Knock-down of the zebrafish homologue klhl24a results in heart defects similar to that described for other HCM-linked genes providing additional support for KLHL24 as a HCM-associated gene. Our findings reveal a crucial role for KLHL24 in cardiac development and function.
1

1 May 2017 in ASAIO Journal
Verified
Journal Article
Closed access
VTVakhtang Tchantchaleishvili
Vakhtang Tchantchaleishvili
JLJessica G. Y. Luc
Jessica G. Y. Luc
CCCaitlin M. Cohan
Caitlin M. Cohan
KPKevin Phan
Kevin Phan
LHLaila Hubbert
Laila Hubbert
HMH. Todd Massey
H. Todd Massey
There is increasing evidence for successful management of end-stage heart failure with continuous-flow left ventricular assist device (CF-LVAD) technology. However, passive flow adjustment at fixed CF-LVAD speed is susceptible to flow balancing issues as well as adverse hemodynamic effects relating to the diminished arterial pulse pressure and flow. With current therapy, flow cannot be adjusted with changes in venous return, which can vary significantly with volume status. This limits the performance and safety of CF-LVAD. Active flow adjustment strategies have been proposed to improve the synchrony between the pump and the native cardiovascular system, mimicking the Frank–Starling mechanism of the heart. These flow adjustment strategies include modulation by CF-LVAD pump speed by synchrony and maintenance of constant flow or constant pressure head, or a combination of these variables. However, none of these adjustment strategies have evolved sufficiently to gain widespread attention. Herein we review the current challenges and future directions of CF-LVAD therapy and sensor technology focusing on the development of a physiologic, long-term active flow adjustment strategy for CF-LVADs.

27 December 2013 in Artificial Organs
Verified
Journal Article
Open access
PDF file
LHLaila Hubbert
Laila Hubbert
PSPer Sundbom
Per Sundbom
MLMatthias Loebe
Matthias Loebe
BPBengt Peterzén
Bengt Peterzén
HGHans Granfeldt
Hans Granfeldt
HAHenrik Ahn
Henrik Ahn
Mechanical circulatory support technology is continually improving. However, adverse complications do occur with devastating consequences, for example, pump thrombosis that may develop in several parts of the pump system. The aim of this study was to design an experimental clot/thrombosis model to register and analyze acoustic signals from the left ventricular assist device (LVAD) HeartMate II (HMII) (Thoratec Corporation, Inc., Pleasanton, CA, USA) and detect changes in sound signals correlating to clots in the inflow, outflow, and pump housing. Using modern telecom techniques, it was possible to register and analyze the HMII pump‐specific acoustic fingerprint in an experimental model of LVAD support using a mock loop. Increase in pump speed significantly (P < 0.005) changed the acoustic fingerprint at certain frequency (0–23 000 Hz) intervals (regions: R1–3 and peaks: P1,3–4). When the ball valves connected to the tubing were narrowed sequentially by ∼50% of the inner diameter (to mimic clot in the out‐ and inflow tubing), the frequency spectrum changed significantly (P < 0.005) in P1 and P2 and R1 when the outflow tubing was narrowed. This change was not seen to the same extent when the lumen of the ball valve connected to the inflow tube was narrowed by ∼50%. More significant (P < 0.005) acoustic changes were detected in P1 and P2 and R1 and R3, with the largest dB figs. in the lower frequency ranges in R1 and P2, when artificial clots and blood clots passed through the pump system. At higher frequencies, a significant change in dB figs. in R3 and P4 was detected when clots passed through the pump system. Acoustic monitoring of pump sounds may become a valuable tool in LVAD surveillance.

1 September 2017 in ASAIO Journal
Verified
Journal Article
Open access
LHLaila Hubbert
Laila Hubbert
JBJacek Baranowski
Jacek Baranowski
BDBaz Delshad
Baz Delshad
HAHenrik Ahn
Henrik Ahn
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelectromechanical system pressure sensor (Titan, ISS Inc., Ypsilanti, MI) was placed in the left atrium in four patients at the time of LVAD implantation. Titan sensor LAP was measured in all four patients on the intensive care unit and in three patients at home. Ramped speed tests were performed using LAP and echocardiography in three patients. The left ventricular end-diastolic diameter (cm), flow (L/min), power consumption (W), and blood pressure (mm Hg) were measured at each step. Measurements were performed over 36, 84, 137, and 180 days, respectively. The three discharged patients had equipment at home and were able to perform daily recordings. There were significant correlations between sensor pressure and pump speed, LV and LA size and pulmonary capillary wedge pressure, respectively (r = 0.92–0.99, p < 0.05). There was no device failure, and there were no adverse consequences of its use.

1 November 2005 in Journal of Cardiovascular Nursing
Verified
Journal Article
Closed access
ABAnders Broström
Anders Broström
LHLaila Hubbert
Laila Hubbert
PJPer Jakobsson
Per Jakobsson
PJPeter Johansson
Peter Johansson
BFBengt Fridlund
Bengt Fridlund
UDUlf Dahlström
Ulf Dahlström
Sleep-disordered breathing (SDB) is common in patients with heart failure (HF) and leads to disturbed sleep. The objective of this study was to determine the persistent effects of long-term nocturnal oxygen treatment in patients with severe HF regarding (1) objective outcomes, such as sleep, SDB, cardiac function, and functional capacity; (2) subjective outcomes, such as self-assessed sleep difficulties, daytime sleepiness, and health-related quality of life (HRQOL); and (3) the relationship between objective and subjective outcomes. In this open nonrandomized experimental study, 22 patients, median age 71 years, with severe HF were studied before and after 3 months of receiving nocturnal oxygen. The measures used were overnight polysomnography, echocardiography, 6-minute walk test, self-assessed sleep difficulties (Uppsala Sleep Inventory-HF), daytime sleepiness (Epworth Sleepiness Scale), and HRQOL (36-Item Short Form Health Survey and Minnesota Living with Heart Failure Questionnaire). SDB, with a 90% dominance of central sleep apnea, occurred in 41% of the patients with severe HF before intervention. After intervention, functional capacity improved for both the whole group of patients with HF (P < .01) and HF patients with SDB (P < .05). No improvements regarding cardiac function, objective sleep, subjective sleep, or SDB were seen, except for a decrease of ≥4% desaturations (P < .05). HRQOL did not differ significantly between HF patients with and without SDB before or after intervention with nocturnal oxygen. Long-term nocturnal oxygen treatment improved functional capacity in patients with severe HF, with or without SDB. No improvements were seen regarding sleep, daytime sleepiness, SDB, cardiac function, or HRQOL.

1 January 2017 in ASAIO Journal
Verified
Journal Article
Open access
LHLaila Hubbert
Laila Hubbert
CFClaes Forssell
Claes Forssell
JBJacek Baranowski
Jacek Baranowski
BLBo Lindgren
Bo Lindgren
JHJonas Holm
Jonas Holm
HAHenrik Ahn
Henrik Ahn
We report the endovascular stenting of an outflow tract thrombosis in a left ventricular assist device in a patient with relative contraindications to sternotomy and pump exchange. This report highlights the importance of simultaneous prevention of stroke using filter devices in the common carotid arteries.