Fatih ÇOLDUR

Prof. Dr. Fatih ÇOLDUR

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GKGulsah Saydan Kanberoglu
Gulsah Saydan Kanberoglu
FÇFatih ÇOLDUR
Fatih ÇOLDUR
CTCihan Topcu
Cihan Topcu
OCOsman Cubuk
Osman Cubuk
Novel tamoxifen-selective potentiometric electrodes based on various ion associations of tamoxifen were developed. The most suitable membrane composition, which has the best potentiometric characteristics, was examined under steady-state conditions. The membrane composed of (w/w) 3% tamoxifen-phosphomolibdate ion pair, 32% poly(vinylchloride), and 65% 2-nitrophenyloctylether was determined as the membrane with the best analytical properties. On the condition of ${\rm pH}=2-6$ , the fabricated electrode exhibited linear responses over the concentration range of $9.1\times \,\, 10^{-6}- 1\times \,\, 10^{-3}$ M tamoxifen solutions ( $R^{2} =0.9989$ ) with a sensitivity of 42.9 ± 0.3 mV/decade, detection limit of $7.3\pm ~0.4 \,\, \times 10^{-6}$ M and short response time of $\approx 25$ s. The influences of some alkaline, alkaline earth metals, biologically significant molecules, and some pharmaceutical species over electrode responses were studied. The proposed electrode was applied for the determination of tamoxifen contents of some pharmaceutical formulations by using standard addition method. The potentiometric analysis results obtained for the pharmaceutical formulations were in good harmony with the results obtained by high performance liquid chromatography at 95% confidence level.


8 May 2022 in Chemical Papers
Verified
Journal Article
Closed access
PDF file
YSYaver Subasi
Yaver Subasi
GKGulsah S. Kanberoglu
Gulsah S. Kanberoglu
FÇFatih ÇOLDUR
Fatih ÇOLDUR
OCOsman Cubuk
Osman Cubuk
MZMehmet Zahmakiran
Mehmet Zahmakiran


9 August 2024 in Microchemical Journal
Verified
Journal Article
Closed access
TCTopcu Cihan
Topcu Cihan
SASenanur Aydin
Senanur Aydin
BABetul Hilal Atasoy
Betul Hilal Atasoy
RYRabia Rana Yilmaz
Rabia Rana Yilmaz
FÇFatih ÇOLDUR
Fatih ÇOLDUR
BCBulent Caglar
Bulent Caglar

1 February 2024 in Journal of the Mexican Chemical Society
Verified
Journal Article
Open access
PDF file
OYOzden Yildirim
Ozden Yildirim
FÇFatih ÇOLDUR
Fatih ÇOLDUR
CTCihan Topcu
Cihan Topcu
BCBulent Caglar
Bulent Caglar
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo-2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all-solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi-walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0×10-6-1.0×10-1 M with a slope of 31.1 mV/decade and a detection limit of 5.0×10-7 M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin. Resumen. En este estudio, inicialmente, se sintetizó una base de Schiff simétrica derivada de la tiourea, (1E,3E)-1,3-bis(5-bromo-2-hidroxibenciliden)tiourea, y se caracterizó mediante análisis FTIR y SEM-EDX. Además, se construyó un sensor potenciométrico selectivo de Cu(II) de estado sólido basado en este compuesto sintetizado como sustancia electroactiva. Los estudios de optimización indicaron que la composición del compuesto sensor óptimo que presentaba las mejores características potenciométricas fue con 3 % de base de Schiff, 5 % de nanotubos de carbono multipared (MWCNT), 20 % de aceite de parafina y 72 % de grafito en masa. El sensor propuesto mostró una respuesta lineal en el rango de concentración de 5×10-6 a 1×10-1 M con una pendiente de 31 mV/década y un límite de detección de 5×10-7 M. El sensor propuesto mostró una respuesta bastante selectiva, estable (deriva de potencial: 1.85 mV/h) y rápida (<10 s) hacia los iones Cu(II). Debido a la magnitud de su deriva de potencial, el sensor debe recalibrarse a lo largo del tiempo de análisis con un intervalo de al menos media hora. El sensor puede emplearse con seguridad en las muestras con pH en el rango de 2.0 a 6.5. La vida útil de la superficie fresca del sensor se determinó en 2 semanas. La ventaja más importante del sensor es que la superficie del compuesto sensor es renovable (al menos 10 veces) y, por tanto, el sensor puede utilizarse muchas veces durante un largo periodo de tiempo. Las aplicaciones analíticas del sensor se llevaron a cabo con éxito, utilizando el electrodo en la valoración potenciométrica de iones Cu(II) con EDTA como electrodo indicador, en la determinación directa del contenido de Cu(II) de muestras de agua enriquecidas y en la determinación del contenido (p/p) de Cu% de una moneda turca.