shengjie lei

Dr. shengjie lei


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2025 in Radiation Measurements
Verified
Journal Article
Closed access
YGYi Guo
Yi Guo
SLshengjie lei
shengjie lei
MFMeihua Fang
Meihua Fang
YZYulian Zhang
Yulian Zhang
XCXinyi Cai
Xinyi Cai
ZWZiqi Wu
Ziqi Wu

14 July 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YGYi Guo
Yi Guo
YZYulian Zhang
Yulian Zhang
YGYipan Guo
Yipan Guo
MFMeihua Fang
Meihua Fang
SLshengjie lei
shengjie lei
XCXinyi Cai
Xinyi Cai

1 May 2012 in Chinese Physics C
Verified
Journal Article
Closed access
PDF file
GCGuo-Yun Chen
Guo-Yun Chen
SLshengjie lei
shengjie lei
YXYong Xin
Yong Xin
SLSheng-Jie Lei
Sheng-Jie Lei
FHFu-Cheng Huang
Fu-Cheng Huang
JMJia-Yi Ma
Jia-Yi Ma

1 January 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
JLJiafeng Li
Jiafeng Li
MZMing Zhang
Ming Zhang
SLshengjie lei
shengjie lei
MFMeihua Fang
Meihua Fang
CFChuanyuan Fu
Chuanyuan Fu
XCXinyi Cai
Xinyi Cai
This study presents the characterization of a compact NaI(Tl)-SiPM detector system for wide-energy gamma-ray spectroscopy from 0.511 to 20.28 MeV. The system utilizes a dual-channel architecture with high-gain and low-gain channels to address dynamic range limitations. Performance was calibrated using standard radioactive sources and quasi-monoenergetic gamma rays produced via inverse Compton scattering at the Shanghai Laser Electron Gamma Source (SLEGS) beamline of the Shanghai Synchrotron Radiation Facility (SSRF). A simulation-based analysis revealed a fundamental challenge for spectroscopy with this compact instrument at high energies. While the total detection efficiency remains high at approximately 30%, the corresponding full-energy peak (FEP) efficiency was found to drop to a negligible 0.01% at 20.28 MeV. This low FEP efficiency, a direct consequence of incomplete energy deposition in the detector's limited volume, precludes the use of traditional photopeak-based calibration in the high-energy domain. A calibration was performed across the full energy range using methodologies appropriate for each domain. In the low-energy range, where photopeaks are well-defined, a standard calibration achieved an energy resolution of 6.64% at 0.662 MeV and a linear response with a coefficient of determination R 2 of 0.99993. To address the challenge in the high-energy range, a non-photopeak methodology using a simulation-corrected characteristic inflection point was validated. This approach yielded a non-linear calibration described by a second-order polynomial with an R 2 of 0.99973. This work thus provides a comprehensive characterization and a viable methodology for utilizing compact detectors in wide energy-range applications, indicating their potential as sensors for advanced systems employing spectrum unfolding.

10 February 2023 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
CWChangji Wang
Changji Wang
JLJinwang Li
Jinwang Li
BXBowen Xu
Bowen Xu
SLshengjie lei
shengjie lei
An integrated airfoil alkali metal high-temperature heat pipe structure is proposed for the air rudder. The heat transfer properties of lithium and sodium are analyzed, and the equal-thickness test pieces are designed and prepared. The sonic limit, condensation limit, viscosity limit, entrainment limit, capillary limit and boiling limit are calculated theoretically, and the corresponding feasible working areas are drawn according to each limit curve. It is found that the optimal working temperature range of the test piece is 800∼1500 K. The effects of heating power and placement angle on the start-up time, isothermal performance, and heat transfer performance of the test piece are studied by experiments. The increase in heating power is helpful to shorten the start-up time and improve the isothermal performance and heat transfer performance of the test piece. The placement angle has little effect on the start-up time, but it has an effect on the isothermal performance and heat transfer performance.

1 November 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
CFChuanyuan Fu
Chuanyuan Fu
YGYi Guo
Yi Guo
SLshengjie lei
shengjie lei
MFMeihua Fang
Meihua Fang
JLJiafeng Li
Jiafeng Li
KTKe Tian
Ke Tian
The detection of radiation in intense fields frequently necessitates high count-rate capabilities. The discernment of neutron signatures from heterogeneous radiation fields characterized by multiple coexisting particle species presents a considerable challenge. Although plastic scintillators endowed with Pulse Shape Discrimination (PSD) capabilities offer a primary modality for neutron-gamma discrimination, the mitigation of charged-particle-induced interference requires coincidence screening methodologies, wherein the anti-coincidence technique is of significant utility. Conventional AC approaches, often reliant upon rudimentary energy thresholding from veto detectors, typically exhibit deficiencies in precise temporal coincidence and event-type characterization. Conversely, acquisition systems based on Full Waveform Digitization, when subjected to high count rates, encounter data transmission bottlenecks attributable to voluminous datasets. To surmount these impediments, this investigation introduces and substantiates a novel hardware-instantiated Anti-Coincidence (AC) system. This system integrates high-speed operational amplifiers, voltage comparators, and radio-frequency analog switches to form an analog signal selection unit, thereby facilitating real-time, analog-domain filtration of signals pertinent to target particles with lower power consumption. Experimental evaluations, conducted with a Silicon Photomultiplier (SiPM) array coupled to a plastic scintillator possessing fast-neutron detection capabilities and exposed to mixed 252 Cf and 90 Sr sources, demonstrate that the hardware AC system reduced the total event count by 89.34 ± 0.03%. More importantly, by efficiently suppressing the electron background, the AC system significantly enhances the reliability of the subsequent PSD analysis. This is evidenced by an increase in the calculated Figure of Merit (FOM) for neutron-gamma discrimination from 1.34 ± 0.02 to 1.41 ± 0.02, This improvement can be explained by the reduction of the electron background in the region of PSD values used for neutron selection.