Beata Sas-Korczyńska

Prof. Dr. Beata Sas-Korczyńska

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2016 in The Breast Journal
Verified
Journal Article
Closed access
PDF file
PSPiotr Skotnicki
Piotr Skotnicki
BSBeata Sas-Korczyńska
Beata Sas-Korczyńska
LSLukasz Strzepek
Lukasz Strzepek
JJJerzy Jakubowicz
Jerzy Jakubowicz
PBPaweł Blecharz¹
Paweł Blecharz¹
TWTomasz Walasek
Tomasz Walasek
Mucinous breast carcinoma (MBC) carcinoma represents approximately 1-6% of all malignant breast carcinoma and is divided into pure (PMBC) and mixed (MMBC) subtypes. This study presents the comparison of clinical characteristics and treatment results in 70 patients with PMBC and 40 patients with MMBC, treated at a single institution during 25 years. Performed analyses showed that only nodal status was different in both subtypes. Patients with MMBC showed a significantly higher incidence of axillary nodal metastases in comparison to PMBC (25% versus 10%, respectively). Instead, the 10-year disease-free survival rate was significant higher in PMBC than MMBC (85.7% versus 65%, p < 0.02, test log rank). Authors own observations and data from literature proved that MMBC should be considered as subtypes of mucinous breast cancer.

21 October 2016 in Medical Science Monitor
Verified
Journal Article
Open access
PDF file
EŁElżbieta Łuczyńska
Elżbieta Łuczyńska
JNJoanna Niemiec
Joanna Niemiec
EHEdward Hendrick
Edward Hendrick
SHSylwia Heinze
Sylwia Heinze
JJJanusz Jaszczyński
Janusz Jaszczyński
JRJanusz Rys
Janusz Rys
BACKGROUND:Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was t...

14 May 2019 in European Radiology
Verified
Journal Article
Open access
PDF file
Wojciech RudnickiWojciech Rudnicki
Wojciech Rudnicki
SHSylwia Heinze
Sylwia Heinze
JNJoanna Niemiec
Joanna Niemiec
ZKZbigniew Kojs
Zbigniew Kojs
BSBeata Sas-Korczyńska
Beata Sas-Korczyńska
EŁElżbieta Łuczyńska
Elżbieta Łuczyńska
Objectives Contrast-enhanced spectral mammography (CESM) is a novel method for breast cancer detection. The aim of this study is to check if there is a possibility of quantitative assessment of contrast enhancement in CESM and if there is any correlation between quantitative assessment of contrast enhancement in CESM and histopathology. Methods A total of 167 female patients underwent CESM. All subjects previously had suspicious lesions found on mammography, breast ultrasound, or both. After imaging, the following parameters were evaluated: number of enhancing lesions in each breast and size and degree of enhancement of each lesion. Based on the collected data, the percentage signal difference between enhancing lesion and background (%RS) and signal-difference-to-noise ratio (SDNR) were measured for each lesion. Results The number of lesions detected in the study population was 195. Among all diagnosed lesions, 120 (62%) were assessed to be infiltrating cancers, 16 (8%) non-infiltrating cancers, and 59 (30%) were benign. Thirteen (7%) lesions did not enhance in CESM; all non-enhancing lesions were confirmed to be benign under histopathological examination. Analysis of enhancement indices showed that signal values within lesions and signal values within background ROIs (regions of interest) were similar in CC (craniocaudal) and MLO (mediolateral) projections. Mean %RS values were correlated with the type of enhancing lesion, infiltrating cancers having the highest values, benign lesions the lowest. Conclusions This work has demonstrated a significant correlation between the degree of lesion enhancement in CESM and malignancy. Quantitative analysis of enhancement levels in CESM can distinguish between invasive cancers and benign or in situ lesions. Key Points • There is a possibility of quantitative assessment of contrast enhancement in CESM. • Correlation between quantitative assessment of contrast enhancement in CESM and histopathology was observed.

27 November 2008
Verified
Journal Article
Closed access
EWEwa Wojcik
Ewa Wojcik
JKJan Kulpa
Jan Kulpa
BSBeata Sas-Korczyńska
Beata Sas-Korczyńska
SKStanisław Korzeniowski
Stanisław Korzeniowski
JJJerzy Jakubowicz
Jerzy Jakubowicz

21 May 2010 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
BSBeata Sas-Korczyńska
Beata Sas-Korczyńska
SKStanisław Korzeniowski
Stanisław Korzeniowski
EWEwa Wójcik
Ewa Wójcik

1 July 2010 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
BSBeata Sas-Korczyńska
Beata Sas-Korczyńska
AŚAnna Śladowska
Anna Śladowska
BRBożena Rozwadowska-Bogusz
Bożena Rozwadowska-Bogusz
SDSonia Dyczek
Sonia Dyczek
JLJan Lesiak
Jan Lesiak
SKStanisław Korzeniowski
Stanisław Korzeniowski
The most often found complications in patients with breast cancer who received radiotherapy are cardiac and pulmonary function disorders and development of second malignancies. To compare the intensity modulated radiotherapy with the 3D tangential beams technique in respect of dose distribution in target volume and critical organs they generate in patients with early-stage breast cancer who received breast-conserving therapy. A dosimetric analysis was performed to assess the three radiotherapy techniques used in each of 10 consecutive patients with early-stage breast cancer treated with breast-conserving therapy. Radiotherapy was planned with the use of all the three techniques: 3D tangential beams with electron boost, IMRT with electron boost, and intensity modulated radiotherapy with simultaneous integrated boost. The use of the IMRT techniques enables more homogenous dose distribution in target volume. The range of mean and median dose to the heart and lung was lower with the IMRT techniques in comparison to the 3D tangential beams technique. The range of mean dose to the heart amounted to 0.3-3.5 Gy for the IMRT techniques and 0.4-4.3 for the tangential beams technique. The median dose to the lung on the irradiated side amounted to 4.9-5 Gy for the IMRT techniques and 5.6 Gy for the 3D tangential beams technique. The application of the IMRT techniques in radiotherapy patients with early-stage breast cancer allows to obtain more homogenous dose distribution in target volume, while permitting to reduce the dose to critical organs.