The analysis of fatty acid methyl esters (FAMEs) is of high relevance for monitoring and control of various industrial processes and biological systems. In this study, a novel, green analytical approach for the determination of 24 FAMEs from aqueous samples is proposed, which is based on a headspace solid-phase microextraction (SPME) arrow followed by gas chromatography coupled to tandem mass spectrometry (GC–MS/MS). The method was substantially accelerated to a run time of 44 min per sample by thorough optimization and automation of the relevant parameters. The limiting parameters, mostly based on expediting equilibrium attainment, were found to be parameters of extraction: material, pH, time, and temperature, which were optimized to divinylbenzene polydimethylsiloxane (DVB-PDMS), pH 2, 20 min, and 70 °C, respectively. The optimization and automation of the method led to low method detection limits (9–437 ng L−1) and high selectivity. Evaluation of the method on real samples was done by analyzing the aqueous phase of a bioreactor, whereby the matrix effect could be greatly reduced due to dilution and headspace sampling. The rapid, sensitive, selective, and matrix-reduced approach is found to be not only a novel method for water analysis but is promising for further applications, e.g., with solid and gaseous samples containing FAMEs. Graphical abstract
30 January 2025 in The Journal of Physical Chemistry C
Coffee is typically brewed by extracting roasted and milled beans with hot water, but alternative methods such as cold brewing became increasingly popular over the past years. Cold-brewed coffee is attributed to health benefits, fewer acids, and bitter substances. But the preparation of cold brew typically needs several hours or even days. To create a cold-brew coffee within a few minutes, we present an approach in which an ultrashort-pulsed laser system is applied at the brewing entity without heating the powder suspension in water, efficiently extracting caffeine and aromatic substances from the powder. Already 3 min irradiation at room temperature leads to a caffeine concentration of 25 mg caffeine per 100 ml, comparable to the concentrations achieved by traditional hot brewing methods but comes without heating the suspension. Furthermore, the liquid phase’s alkaloid content, analyzed by reversed-phase liquid chromatography coupled to high-resolution mass spectrometry, is dominated by caffeine and trigonelline and is comparable to traditional cold-brewed coffee rather than hot-brewed coffee. Furthermore, analyzing the head-space of the prepared coffee variants, using in-tube extraction dynamic head-space followed by gas chromatography coupled to mass spectrometry, gives evidence that the lack of heating leads to the preservation of more (semi-)volatile substances like pyridine, which provide cold-brew coffee its unique taste. This pioneering study may give the impetus to investigate further the possibility of cold-brewing coffee, accelerated by more than one order of magnitude, using ultrafast laser systems.
23 September 2023 in Analytical and Bioanalytical Chemistry
Fatty acids (FAs) and fatty acid methyl esters (FAMEs) co-occur in many samples, and analysis of both substance classes is frequently of high interest. To this end, this study introduces the first method for simultaneous determination of FAs and FAMEs including fully automated solvent-free solid-phase microextraction (SPME) arrow headspace extraction combined with isotope-labeling in situ FA derivatization with deuterated methanol (CD3OD). By using the chromatographic isotope effect (ΔRt = 0.03 min) and the + 3 m/z mass shift, FAs can be selectively differentiated from the FAMEs during gas chromatography tandem-mass spectrometry (GC–MS/MS) operated in the multiple reaction monitoring (MRM) aquisition mode. Additionally, an approach is presented to predict the retention times of deuterated compounds. Optimization of the derivatization conditions was accomplished by design of experiments and found to be 20 min, 50 °C, 4 v/v% CD3OD, and pH 2.1. During method validation, FAs and FAMEs were calibrated in different concentration ranges by standard addition in five real matrices and ultrapure water leading to good linearities and method detection limits for FAs ranging from 1–30 µg L−1 and for FAMEs from 0.003–0.72 µg L−1. FAs and FAMEs were detected in real samples from surface water, wastewater treatment plant effluent, and three different bioreactor samples and could be quantified in concentrations ranging from 2–1056 µg L−1 for FAs and 0.01–14 µg L−1 for FAMEs. Graphical Abstract