Objective: The aim of this study was to evaluate whether a 3-dimensional (3D) camera can outperform highly trained technicians in precision of patient positioning and whether this transforms into a reduction in patient exposure. Materials and Methods: In a single-center study, 3118 patients underwent computer tomography (CT) scans of the chest and/or abdomen on a latest generation single-source CT scanner supported with an automated patient positioning system by 3D camera. One thousand five hundred fifty-seven patients were positioned laser-guided by a highly trained radiographer (camera off) and 1561 patients with 3D camera (camera on) guidance. Radiation parameters such as effective dose, organ doses, CT dose index, and dose length product were analyzed and compared. Isocenter accuracy and table height were evaluated between the 2 groups. Results: Isocenter positioning was significantly improved with the 3D camera (P < 0.001) as compared with visual laser-guided positioning. Absolute table height differed significantly (P < 0.001), being higher with camera positioning (165.6 ± 16.2 mm) as compared with laser-guided positioning (170.0 ± 20.4 mm). Radiation exposure decreased using the 3D camera as indicated by dose length product (321.1 ± 266.6 mGy·cm; camera off: 342.0 ± 280.7 mGy·cm; P = 0.033), effective dose (3.3 ± 2.7 mSv; camera off: 3.5 ± 2.9; P = 0.053), and CT dose index (6.4 ± 4.3 mGy; camera off: 6.8 ± 4.6 mGy; P = 0.011). Exposure of radiation-sensitive organs such as colon (P = 0.015) and red bone marrow (P = 0.049) were also lower using the camera. Conclusions: The introduction of a 3D camera improves patient positioning in the isocenter of the scanner, which results in a lower and also better balanced dose reduction for the patients.
Purpose: Controversy exists on the association of arterial hypertension (HTN) and neurovascular compression (NVC) at the ventrolateral medulla (VLM). No standardized and reproducible technique has been introduced yet for detection of NVC in HTN. This study aimed to generate, analyze and compare different results of exact reproducible anatomical 3D-representations of the VLM in patients with HTN, based on magnetic resonance imaging (MRI). Methods: A 3T scanner provided MRI (T2-constructive interference in steady state (CISS) high resolution imaging and three-dimensional Time-of-flight (3D-TOF) angiography) from the posterior fossa of 44 patients with clinical treatment-resistant HTN. Image processing consists of segmentation of the CISS data, registration and fusion of the CISS and TOF data and visualization. For each patient two 3D-visualizations (before and after fusion) were obtained. The reproduction quality of the vessels, flow-related signal variability and pulsation artifacts were analyzed and compared, using a ranking score. Results: Integrating vascular information from TOF into CISS data reduced artifacts in 3D-visualizations of exclusively processed CISS data. The quality of 3D-visualization of the vessels near the brain stem was significantly improved (p = 0.004). The results were reproducible and reliable. The quality of the 3D-presentations of neurovascular relationships at the VLM improved significantly (p < 0.001). Conclusion: The 3D-visualization of fused image data provides an excellent overview of the relationship between cranial nerves and vessels at the VLM and simplifies the detection of NVC in HTN. It provides a powerful tool for future clinical and scientific research. Although microvascular decompression (MVD) in treatment resistant HTN is not a standard procedure, it can be discussed in selected patients with intractable severe HTN.
30 June 2022 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: There is growing evidence of leakage of gadolinium in an impaired blood-retina barrier. We investigated gadolinium enhancement in different eye compartments and correlated the enhancement with specific ophthalmologic diseases. MATERIALS AND METHODS: In a prospective clinical study (ClinicalTrials.gov Identifier: NCT05035251), 95 patients (63 with and 32 without ophthalmologic disease) were examined before and after gadolinium administration (20 and 120 minutes) with heavily T2-weighted FLAIR. The cohort was divided according to the location of pathology into anterior and posterior eye compartment groups. Relative signal intensity increase in the anterior eye chamber, vitreous body with retina, optic nerve sheath, and the Meckel cave was analyzed and correlated with the final clinical diagnosis. RESULTS: In patients with a disorder in the anterior eye compartment, significant signal intensity increases were found in the central anterior eye chamber (P 20 minutes = .000, P 120 minutes = .000), lateral anterior eye chamber (P 20 minutes = .001, P 120 minutes = .005), and vitreous body with retina (P 20 minutes = .02) compared with the control group. Patients with pathologies in the posterior eye compartment showed higher signal intensity levels in the central anterior eye compartment (P 20 minutes = .041) and vitreous body with retina (P 120 minutes = .006). CONCLUSIONS: Increased gadolinium enhancement was found in the central and lateral anterior eye compartments and the vitreous body with retina in patients with anterior eye compartment disorders 20 and 120 minutes after contrast application, suggesting impairment of the blood-aqueous barrier. In patients with a disorder in the posterior eye compartment, pathologic enhancement indicated disruption of the blood-retinal barrier that allows gadolinium to diffuse into the vitreous body with retina from posterior to anterior, opposite to the known physiologic glymphatic pathway.
1 January 2020 in European Journal of Radiology Open
To investigate contrast dynamics and artifacts associated with different breathing maneuvers during pulmonary computed tomography angiography (pCTA) in a prospective randomized clinical trial. Three different breathing maneuvers (inspiration, expiration, Mueller) were randomly assigned to 146 patients receiving pCTA for suspected pulmonary embolism (PE). Contrast enhancement of central and peripheral arteries and imaging quality of lung parenchyma were compared and analyzed. Results were compared by using the analysis of variances (ANOVA) and Kruskal-Wallis-Test. Mean enhancement in the pulmonary trunk was highest during breath-hold in inspiration (293 HU, range 195–460 HU) compared to Mueller (259 HU, range 136–429 HU, p = 0022) and expiration (267 HU, range 115–376 HU). This was similar for the right pulmonary artery (inspiration 289 HU, range 173–454 HU; Mueller 250 HU, range 119–378 HU; p = 0.007; expiration 257 HU, range 114–366 HU; p = 0.032) and left pulmonary artery (inspiration 280.3 HU, range 170–462 HU; Mueller 245 HU, range 111–371 HU; p = 0.016; expiration 252 HU, range 110–371 HU). Delineation of peripheral arteries was significantly better in inspiration vs Mueller (p = 0.006) and expiration (p = 0.049). Assessment of the lung parenchyma was significantly better in inspiration vs Mueller (p = 0.013) or expiration (p < 0.001). Resting inspiratory position achieved the highest enhancement levels in central and peripheral pulmonary arteries and best image quality of the pulmonary parenchyma in comparison to other breathing maneuvers. It is necessary to train the maneuver prior to the examination in order to avoid deep inspiration with the risk of suboptimal opacification of the pulmonary arteries.
The differential diagnosis of retroperitoneal masses includes a variety of benign and malignant conditions, among which infections constitute a significant subgroup. Familiarity with these infectious pseudotumours could facilitate prompt diagnosis. In this report, we describe three patients with an infectious pseudotumour, which was clinically and radiologically highly suggestive of a neoplasm. The first patient was a 62-year-old woman with a history of Richter syndrome, who seven months after allogeneic haematopoetic stem cell transplantation from an unrelated donor presented with a renal mass. A renal biopsy at that time revealed necrotic tissue. The patient displayed multiple relapses of Richter syndrome (for which she received also chimeric antigen receptor T-cell therapy salvage chemotherapy) and remissions of the lymphoma as well as an Aspergillus pneumonia for which she was treated with intravenous ambisome and afterwards oral posaconazole. Since the renal mass persisted and to exclude malignancy, nephrectomy was performed which revealed the presence of fungal hyphae. The second patient was a 51-year-old man with a history of a low-grade non-muscle-invasive bladder urothelial carcinoma, who after Mycobacterium bovis Calmette-Guerin instillation presentedwith fever and a suspicious renal mass. A partial nephrectomy was performed. Intraoperative frozen section analysis and routine histology suggested a Mycobacterium bovis-associated lesion, which was confirmed by polymerase chain reaction (PCR) analysis. The third patient was an 85-year-old man who presented with loss of appetite, fatigue, and significant weight loss (24 Kg in less than a year) as well as a travel history. The laboratory tests showed a low sodium and a high potassium level. CT scans revealed a solitary lesion in the right lung, a small liver lesion as well as bilateral adrenal lesions. A CT-guided biopsy revealed the presence of Histoplasma capsulatum, which was confirmed by PCR analysis. A retrospective review of all parameters indicates that all three patients presented with some risk factors, such as immunosuppression, travel, or clinical history that could raise the suspicion of infection in order to be included in the differential diagnosis, thus providing an additional tool for timely diagnosis.
Background/Objectives: The aim of this study was to identify predictors of temporal window failure (TWF) in transcranial color-coded duplex sonography (TCCS) based on demographical and computed tomography (CT)-based parameters such as temporal bone thickness (TBT), and to define sex-specific thresholds for predicting TWF. Methods: We retrospectively analyzed a series of adult patients who underwent cranial CT and TCCS. Bitemporal TBT was measured in nine standardized regions on CT, and mean TBT per side was calculated. Temporal bone window (TBW) quality was graded with two semiquantitative TCCS scores assessing the visibility of the middle cerebral artery (MCA), contralateral temporal bone, mesencephalon, and ipsilateral sphenoid bone. Associations between TBT, sex, age, and TBW visibility were analyzed by correlation, chi-square tests, and logistic regression. Results: 200 patients (102 men, 98 women; mean age 68 ± 16 years) were enrolled. Mean TBT was 3.1 ± 0.7 mm (right) and 3.2 ± 0.7 mm (left). TBT correlated weakly with age (r = 0.15–0.18, p < 0.05) and was higher in women (p < 0.05). Age and sex influenced TBW visibility (p < 0.05) with small effect sizes. Increased TBT strongly predicted poor TBW (β ≈ –1.7, p < 0.001). Optimal TBT cut-offs predicting adequate TBW were 3.8 mm (men) and 3.3 mm (women), maximizing specificity (men: 0.95, women: 0.85) and negative predictive value (men: 0.87, women: 0.66). Conclusions: Advanced age and female sex were both associated with TWF. CT-assessed TBT represents a robust predictor of TCCS feasibility. Implementation of sex-specific TBT threshold values may facilitate patient pre-selection and improve procedural efficiency in neurosonographic diagnostics.