Alessandra Huscher

Dr. Alessandra Huscher


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2017 in Acta Oncologica
Verified
Journal Article
Open access
DCDelia Ciardo
Delia Ciardo
AAAngela Argenone
Angela Argenone
GBGenoveva Ionela Boboc
Genoveva Ionela Boboc
FCFrancesca Cucciarelli
Francesca Cucciarelli
FRFiorenza De Rose
Fiorenza De Rose
O(on the behalf of the Breast Working Group of the Italian Association of Radiation Oncology (AIRO)
on the behalf of the Breast Working Group of the Italian Association of Radiation Oncology (AIRO)
Aim: To quantify the variability between radiation oncologists (ROs) when outlining axillary nodes in breast cancer. Material and methods: For each participating center, three ROs with different levels of expertise, i.e., junior (J), senior (S) and expert (E), contoured axillary nodal levels (L1, L2, L3 and L4) on the CT images of three different patients (P) of an increasing degree of anatomical complexity (from P1 to P2 to P3), according to contouring guidelines. Consensus contours were generated using the simultaneous truth and performance level estimation (STAPLE) method. Results: Fifteen centers and 42 ROs participated. Overall, the median Dice similarity coefficient was 0.66. Statistically significant differences were observed according to the level of expertise (better agreement for J and E, worse for S); the axillary level (better agreement for L1 and L4, worse for L3); the patient (better agreement for P1, worse for P3). Statistically significant differences in contouring were found in 18% of the inter-center comparison. Less than a half of the centers could claim to have a good agreement between the internal ROs. Conclusions: The overall intra-institute and inter-institute agreement was moderate. Central lymph-node levels were the most critical and variability increased as the complexity of the patient’s anatomy increased. These findings might have an effect on the interpretation of results from multicenter and even mono-institute studies.

9 May 2023 in The Breast Journal
Verified
Journal Article
Open access
PDF file
ALAndrea Vittorio Emanuele Lisa
Andrea Vittorio Emanuele Lisa
MSMarzia Salgarello
Marzia Salgarello
AHAlessandra Huscher
Alessandra Huscher
FCFabio Corsi
Fabio Corsi
DPDaniele Piovani
Daniele Piovani
MKMarco Klinger
Marco Klinger
Purpose. In modern breast cancer treatment, a growing role has been observed for breast reconstruction together with an increase in clinical indications for postmastectomy radiotherapy (PMRT). Choosing the optimum type of reconstructive technique is a clinical challenge. We therefore conducted a national multicenter study to analyze the impact of PMRT on breast reconstruction. Methods. We conducted a retrospective case-control multicenter study on women undergoing breast reconstruction. Data were collected from 18 Italian Breast Centres and stored in a cumulative database which included the following: autologous reconstruction, direct-to-implant (DTI), and tissue expander/immediate (TE/I). For all patients, we described complications and surgical endpoints to complications such as reconstruction failure, explant, change in type of reconstruction, and reintervention. Results. From 2001 to April 2020, 3116 patients were evaluated. The risk for any complication was significantly increased in patients receiving PMRT (aOR, 1.73; 95% CI, 1.33–2.24; ). PMRT was associated with a significant increase in the risk of capsular contracture in the DTI and TE/I groups (aOR, 2.24; 95% CI, 1.57–3.20; ). Comparing type of procedures, the risk of failure (aOR, 1.82; 95% CI, 1.06–3.12, ), explant (aOR, 3.34; 95% CI, 3.85–7.83, ), and severe complications (aOR, 2.54; 95% CI, 1.88–3.43, ) were significantly higher in the group undergoing DTI reconstruction as compared to TE/I reconstruction. Conclusion. Our study confirms that autologous reconstruction is the procedure least impacted by PMRT, while DTI appears to be the most impacted by PMRT, when compared with TE/I which shows a lower rate of explant and reconstruction failure. The trial is registered with NCT04783818, and the date of registration is 1 March, 2021, retrospectively registered.

24 January 2024 in Gynecologic Oncology
Verified
Journal Article
Closed access
Gabriella MacchiaGabriella Macchia
Gabriella Macchia
Savino CillaSavino Cilla
Savino Cilla
DPDonato Pezzulla
Donato Pezzulla
MCMaura Campitelli
Maura Campitelli
CLConcetta Laliscia
Concetta Laliscia
FDFrancesco DEODATO
Francesco DEODATO

18 June 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
MLMaria Cristina Leonardi
Maria Cristina Leonardi
Matteo PepaMatteo Pepa
Matteo Pepa
SGSimone Giovanni Gugliandolo
Simone Giovanni Gugliandolo
RLRosa Luraschi
Rosa Luraschi
SVSabrina Vigorito
Sabrina Vigorito
BJBarbara Alicja Jereczek-Fossa
Barbara Alicja Jereczek-Fossa
Objectives: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV). Methods: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them. Results: Eighteen RT centres participated in the study. Comparative analyses revealed that, on average, the SC-CTVs were smaller than GS-CTV for P1 and P2 (by −29.25% and −27.83%, respectively) and larger for P3 (by +12.53%). The mean Jaccard index was greater for P1 and P2 compared to P3, but the overlap extent value was around 0.50 or less. Regarding nodal levels, L4 showed the highest concordance with the GS. In the intra-patient comparison, L2 and L3 achieved lower TS than L4. Nodal levels showed discrepancy with GS, which was not statistically significant for P1, and negligible for P2, while P3 had the worst agreement. DICE similarity coefficient did not exceed the minimum threshold for agreement of 0.70 in all the measurements. Conclusions: Substantial differences were observed between SC- and GS-CTV, especially for P3 with altered arm setup. L2 and L3 were the most critical levels. The study highlighted these key points to address. Advances in knowledge: The present study compares, by means of validated geometric indexes, manual segmentations of axillary lymph nodes in breast cancer from different observers and different institutions made on radiotherapy planning CT images. Assessing such variability is of paramount importance, as geometric uncertainties might lead to incorrect dosimetry and compromise oncological outcome.

1 May 2017 in Breast Cancer Management
Verified
Journal Article
Open access
AHAlessandra Huscher
Alessandra Huscher
DSDina Santus
Dina Santus
ASAlberto Soregaroli
Alberto Soregaroli
SMStefano Mutti
Stefano Mutti
GLGabriele Levrini
Gabriele Levrini
MBMario Bignardi
Mario Bignardi
Aim: The aim was identification of reference structures for breast clinical target volume (CTV) in prone position, throughout image fusion process. Materials & methods: We analyzed breast glandular tissue distribution in 20 diagnostic MRIs, referring to structures reported in ESTRO guidelines for supine irradiation. The volume containing breast glandular tissue in all cases was defined as MRI prone CTV (MRIpCTV). Then in ten subsequent patients planned for prone irradiation, MRI and computed tomography (CT) simulation was acquired. MRIpCTV was defined followed by our findings and transferred to CT for definitive delineation. Results: MRIpCTV was defined by the caudal edge of clavicular head, 3 mm above inframammary fold, by the medial thoracic artery, by a plane passing through the lateral surface of pectoralis muscles, by the anterior surface of pectoralis muscles and 3 mm from the skin. Deformed CTV was consistent with anatomy on CT; the limits chosen for MRIpCTV fit adequately also for CT. Conclusion: ...