Mehmetzeki Yıldız

Dr. Mehmetzeki Yıldız


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
UÖUtku Özgen
Utku Özgen
MYMehmetzeki Yıldız
Mehmetzeki Yıldız
MAMehmet Osman Akçakaya
Mehmet Osman Akçakaya
TKTalat Kırış
Talat Kırış
Background and Objectives: The authors aimed to describe their experience performing frameless stereotactic biopsies using an Autoguide Robotic Platform and to compare the outcomes with a frame-based stereotactic technique. We would like to emphasize the importance of this study, as it is the first in the literature to use sodium fluorescein for confirmation in intracranial biopsies taken with a Stealth Autoguide Robotic Platform. Materials and Methods: We retrospectively evaluated 30 patients who underwent a stereotactic intracranial biopsy between June 2018 and March 2024. The patients were divided into two groups: The robotic biopsy group (n = 15) underwent a frameless image-guided stereotactic intracranial biopsy with a Stealth Autoguide Robotic Platform and optical neuronavigation system (Stealth-Station S8, Medtronic, Minneapolis, MN, USA) using intraoperative sodium fluorescein. The frame-based (Integra, CRW, New Jersey, USA) stereotactic biopsy group (n = 15) underwent a stereotactic biopsy with the use of a stereotactic planning system (Atlas Integra Software, NJ, USA and Brainlab AG, Munich, Germany) without sodium fluorescein. Preoperative MRI and CT scans were performed in all the patients. Their external cranial anatomy was registered using either facial tracing or O-Arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA). Results: The robotic biopsy group demonstrated a diagnostic yield of 93.3% (14/15), while the frame-based group achieved 100% (15/15), with no significant difference (p = 0.609). The mean calculated tip error in the robotic biopsy group was 0.42 ± 0.19 mm (range: 0.1–0.7 mm) and the postoperative targeting accuracy in the frame-based biopsy group was 0.51 ± 0.23 mm (range: 0.2–0.9 mm), with no significant difference (p = 0.287). The robotic biopsy group demonstrated a significantly shorter mean surgical time (40.26 ± 6.13 vs. 52.47 ± 8.92 min, p = 0.002). Conclusions: Both frame-based and robotic-assisted stereotactic biopsy techniques achieve comparable diagnostic accuracy and targeting precision. However, a robotic biopsy significantly reduces the surgical time compared to a frame-based technique. The use of intraoperative sodium fluorescein is a valuable adjunct method for confirming that biopsy specimens are obtained from the intended target site.

20 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
UÖUtku Özgen
Utku Özgen
MYMehmetzeki Yıldız
Mehmetzeki Yıldız
MAMehmet Osman Akçakaya
Mehmet Osman Akçakaya
TKTalat Kırış
Talat Kırış
Background and Objectives: The authors aimed to describe their experience in frameless stereotactic biopsy by using Autoguide Robotic Platform and compare outcomes with frame-based stereotactic technique. We would like to emphasize the importance of this study as it is the first in the literature to use sodium fluorescein for confirmation in intracranial biopsies taken with the Stealth Autoguide Robotic Platform. Materials and Methods: We retrospectively evaluated 30 patients who underwent stereotactic intracranial biopsy between June 2018 and March 2024. Patients were divided into two groups: Robotic biopsy group (n=15) underwent frameless image-guided stereotactic intracranial biopsy with Stealth Autoguide Robotic Platform and optical neuronavigation system (Stealth-Station S8, Medtronic, Minneapolis, MN, USA) by using intraoperative sodium fluorescein. Frame-based (Integra, CRW, New Jersey, USA) stereotactic biopsy group (n=15) underwent stereotactic biopsy with the use of a stereotactic planning system (Atlas Integra Software, New Jersey, USA and Brainlab AG, Munich, Germany), without sodium fluorescein and preoperative MRI and CT scans were performed in all patients. The external cranial anatomy was registered using either facial tracing or O-Arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA). Results: Robotic biopsy group demonstrated diagnostic yield of 93.3% (14/15) while frame-based group achieved 100% (15/15), with no significant difference (p=0.609). Mean calculated tip error in robotic biopsy group was 0.42±0.19 mm (range: 0.1-0.7 mm) and postoperative targeting accuracy in frame-based biopsy group was 0.51±0.23 mm (range: 0.2-0.9 mm), with no significant difference (p=0.287). robotic biopsy group demonstrated significantly shorter mean surgical time (40.26±6.13 vs 52.47±8.92 minutes, p=0.002). Conclusions: Both frame-based and robotic-assisted stereotactic biopsy techniques achieve comparable diagnostic accuracy and targeting precision. However, robotic biopsy significantly reduces surgical time compared to frame-based technique. The use of intraoperative sodium fluorescein is a valuable adjunct method for confirming that biopsy specimens are obtained from the intended target site.