Fengju Zhang

Dr. Fengju Zhang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Current Eye Research
Verified
Journal Article
Closed access
MZMingyue Zhang
Mingyue Zhang
FZFengju Zhang
Fengju Zhang
YLYu Li
Yu Li
YSYanzheng Song
Yanzheng Song
ZWZhiqun Wang
Zhiqun Wang
Purpose: This study was designed to evaluate and compare the sensitivity and specificity of the Belin/Ambrósio Deviation (BADD), Corneal Biomechanical Index (CBI) and Tomographic and Biomechanical Index (TBI) for the diagnosis of keratoconus in Chinese myopic eyes prior to undergoing corneal refractive surgery. Methods: A total of 125 patients (185 eyes) planned to undergo corneal refractive surgery were selected from the Refractive Center of Beijing Tongren Hospital between December 2017 and December 2018. They were divided into four groups: the normal group, bilateral keratoconus (BK) group, unilateral keratoconus (UK) group, and the forme fruste keratoconus (FFK) group. After determining the BADD, CBI, and TBI for each eye using the Corvis ST combined with Pentacam, the sensitivity and specificity of these three indices in diagnosing keratoconus were analyzed through receiver operating characteristic (ROC) curves. Results: The TBI exhibited the highest diagnostic efficiency in normal vs. UK (area under the ROC curve [AUROC]: 0.992), normal vs. UK+BK (AUROC: 0.988), normal vs. UK+BK* (*stand randomly selecting one eye of each patient in BK group) (AUROC: 0.982), normal vs. UK+BK+FFK (AUROC: 0.965), and normal vs. UK+BK*+FFK (AUROC: 0.953). The CBI demonstrated the highest diagnostic efficiency in normal vs. FFK (AUROC: 0.897). Finally, the BADD showed the highest diagnostic efficiency in normal vs. BK (AUROC: 0.998) and normal vs. BK* (AUROC: 0.996). Conclusion: The BADD, CBI, and TBI performed well in diagnosing keratoconus in Chinese myopic eyes. The CBI showed the highest diagnostic efficiency compared with normal for FFK. In addition, the TBI offered the greatest accuracy in detecting keratoconus and FFK eyes vs. the other parameters.

8 February 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
YQYa Qi
Ya Qi
LLLizhou Liu
Lizhou Liu
YLYu Li
Yu Li
FZFengju Zhang
Fengju Zhang
Background: To study the baseline factors that related to faster axial elongation after orthokeratology (OK) treatment and the characteristics of cases with axial length decrease in a group of myopia children. Methods: This is a retrospective study. The records of 73 children who had wear OK lens for at least one year were reviewed. Only the data of right eyes were included. Baseline data included: age, gender, parental myopia, refractive error, corneal power, central corneal thickness, axial length and anterior chamber depth. Corneal power, central corneal thickness, anterior chamber depth and axial length after one-year of OK lens wear were also collected. The related factors affecting axial length change were analyzed. A comparison was made on the cases of axial length increase and axial length decrease. Results: Of the 73 eyes, axial length increased by 0.18 ± 0.17 mm (P < 0.001) after one year of OK lens wear. Correlation analysis showed that one-year axial length change was negatively correlated with age and positively correlated with the parental myopia and baseline myopia. Stepwise multiple linear regression analysis showed that the factors associated with faster axial elongation were lower baseline myopic spherical equivalent (P = 0.018), higher parental myopia degree (P = 0.026), and younger age at the onset of lens wear. (P = 0.039). Nine eyes showed negative axial growth (−0.06 ± 0.04 mm), and had older initial age of lens wear, higher baseline myopic spherical equivalent, and lager baseline corneal power, when compared with cases of axial length increase. Conclusions: Myopia children with lower baseline myopic spherical equivalent, younger initial age and higher parental myopia had faster axial elongation after orthokeratology treatment. More aggressive treatment should be considered. In children with slow axial elongation, OK lens wear may lead to negative axial growth. Whether there are reasons other than central corneal thinning and choroidal thickening needs further study.

18 April 2019 in Current Eye Research
Verified
Journal Article
Closed access
GLGang Liang
Gang Liang
LWLi Wang
Li Wang
ZPZhiqiang Pan
Zhiqiang Pan
FZFengju Zhang
Fengju Zhang
Purposes: To (i) evaluate various methods for preserving refractive lenticules (RLs) from myopic eyes following small-incision lenticule extraction (SMILE), in order to (ii) establish a sound, standard storage RL preservative for clinical uses. Methods: In this prospective study, we compared freshly excised post-SMILE RLs (control group) with post-SMILE RLs (experimental group). Experimental group RLs were preserved in one of several preservatives: glycerol, allochroic silicagel desiccant, or Optisol. Following preservation in one of these three media, samples were evaluated by light microsopy (LM), and transmission (TEM) and scanning (SEM) electron microscopy on days-1, -3, -7, and -14. Results: Changes in cellular morphology were observed at all time points.Compared with fresh control-group RLs, there were significant histological changes in RLs preserved in glycerol and allochroic silicagel, but not Optisol. Comparison of the three methods revealed Optisol to be the best, followed by allochroic silica gel desiccant, followed by glycerol. RLs preserved in Optisol maintained the highest degree of viability and integrity. And the RLs viability and collagen density decreased with prolongation of storage time all. Conclusions: Optisol is a mid- term corneal storage medium, which can maintain post-SMILE corneal RLs for 14days, is feasible and effective method for tissue storage.

1 February 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
CHChunchun He
Chunchun He
JJJoern S. Joergensen
Joern S. Joergensen
MKMichael C. Knorz
Michael C. Knorz
KMKeith N. McKay
Keith N. McKay
FZFengju Zhang
Fengju Zhang
PURPOSE: To evaluate vision and corneal surface regularity after each step of a three-step surgical treatment of keratoconus and post–laser in situ keratomileusis (LASIK) ectasia (implantation of intracorneal ring segments [ICRS], corneal cross-linking [CXL], and implantation of toric intraocular contact lenses [ICLs]). METHODS: Thirty-one eyes of 24 patients with moderate to severe keratoconus and post-LASIK ectasia (stages II and III of Amsler–Krumeich classification) were included. All eyes underwent all three steps. The time interval between ICRS implantation and CXL was 4 to 6 weeks, and ICL implantation was performed 6 to 8 months after CXL. Visual acuity, refraction, and corneal topometric indices were evaluated with the Pentacam system (index of surface variance [ISV], index of vertical asymmetry [IVA], keratoconus index [KI], central keratoconus index [CKI], index of height asymmetry [IHA], index of height decentration [IHD], and corneal wavefront parameters [eg, higher order aberrations, spherical aberration, and coma]). RESULTS: Decimal uncorrected distance visual acuity (UDVA) improved from 0.13 ± 0.17 preoperatively to 0.69 ± 0.18 at 1 year, whereas corrected distance visual acuity (CDVA) improved from 0.56 ± 0.24 to 0.80 ± 0.18, respectively. The topometric indices ISV, IVA, KI, and IHD also improved significantly, whereas CKI and IHA showed no significant improvement. Higher order aberrations, spherical aberration, and coma improved significantly compared to baseline. CONCLUSIONS: The combined use of ICRS, CXL, and ICL implantation significantly improves visual acuity, higher order aberrations, and corneal shape in moderate and severe keratoconus and post-LASIK ectasia. [ J Refract Surg . 2020;36(2):104–109.]

18 October 2018 in Current Eye Research
Verified
Journal Article
Closed access
DWDan Wang
Dan Wang
YLYu Li
Yu Li
MSMing Shen Sun
Ming Shen Sun
NGNing Guo
Ning Guo
FZFengju Zhang
Fengju Zhang
PURPOSE: To evaluate the differences between the estimated and measured lenticule thickness and relationships in myopic eyes with different refractive errors after small-incision lenticule extraction (SMILE). METHODS: This prospective study included a total of 190 eyes (96 patients) with a manifest refraction spherical equivalent (MRSE) of −6.16 ± 1.71 D. The measured lenticule thickness was obtained from digital spectral-domain optical coherence tomography image analysis. The estimated lenticule thickness was obtained from the software program. Comparative statistics and linear regression analyses were performed. RESULTS: At 1 month, the estimated lenticule thickness was 113.68 ± 19.35 µm and the measured lenticule thickness was 96.9 ± 17.5 µm. The difference between the estimated and measured lenticule thickness was 13.63 ± 9.1 µm (p < 0.001) thicker. The difference was lower than the mean data in the moderate myopia group (9.7 ± 6.4 µm) and larger in the high myopia group (12.3 ± 8.8 µm) and the super-high myopia group (17.9 ± 6.9 µm). The discrepancy between the estimated and measured lenticule thickness was significantly dependent on the MRSE (p < 0.001). MRSE only showed significant differences between the three and six-month follow-up visit in the super-high myopic group (p = 0.03). CONCLUSION: The measured lenticule thickness was thinner than the estimated lenticule thickness for SMILE in most eyes. The higher the refraction, the larger the difference after SMILE surgery. The mismatch between the estimated and measured thickness did not influence the refractive precision and stability of different refractive errors.

5 April 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
JZJihong Zhou
Jihong Zhou
WGWei Gu
Wei Gu
YGYan Gao
Yan Gao
GHGuoli He
Guoli He
FZFengju Zhang
Fengju Zhang
Background: The purpose of this study was to compare the astigmatic correction by vector analysis in patients with high myopic astigmatism after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) with cyclotorsion compensation or small-incision lenticule extraction (SMILE) with stringent head positioning. Setting: Beijing Aier-Intech Eye Hospital, Beijing, China. Design: A retrospective case series. Methods: Patients who had correction of myopic astigmatism of 2 diopters (D) or more treated with either FS-LASIK with cyclotorsion compensation or SMILE with stringent head positioning were included. The results of vision and refraction were analyzed and compared between groups with the right eye. Results: The study enrolled 94 patients (41eyes in an FS-LASIK with compensation of cyclotorsion group and 53 eyes in a SMILE with stringent head positioning control group. The mean preoperative manifest cylinder was -2.65 ± 0.77D in the FS-LASIK group and 2.51 ± 0.56D in the SMILE group (P = 0.302). At 12 months, there was no significant between-group difference in uncorrected distance visual acuity (UDVA, P = 0.274) and postoperative spherical equivalent (SEQ) (P = 0.107). 46.3% and 24.5% of eyes in the FS-LASIK and SMILE groups were within 0.25 D were within 0.25D postoperative cylinder, respectively, and 78% and 66% of eyes in these two groups were within 0.5 D postoperative cylinder (P = 0.027, P = 0.202). The vector analysis showed comparable between-group target-induced astigmatism (TIA) (P = 0.114), surgically induced astigmatism (SIA) (P = 0.057), difference vector (DV, P = 0.069), and the angle of error (AE) (P = 0 .213) values. The index of success (IOS) was 0.18 in the FS-LASIK group and 0.24 in the SMILE group (P = 0.024), with a significant difference between the two groups. Conclusion: FS-LASIK with compensation of cyclotorsion showed a favorable correction of high myopic astigmatism (≥ 2.0 D) compared to SMILE with stringent head positioning at 12 months.