Miltiadis Matsagkas

Dr. Miltiadis Matsagkas


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
PTPaola Tasso
Paola Tasso
ARAnastasios Raptis
Anastasios Raptis
MMMiltiadis Matsagkas
Miltiadis Matsagkas
MRMaurizio Lodi Rizzini
Maurizio Lodi Rizzini
Diego GalloDiego Gallo
Diego Gallo
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
Endovascular aneurysm repair (EVAR) has disseminated rapidly as an alternative to open surgical repair for the treatment of abdominal aortic aneurysms (AAAs), because of its reduced invasiveness, low mortality, and morbidity rate. The effectiveness of the endovascular devices used in EVAR is always at question as postoperative adverse events can lead to re-intervention or to a possible fatal scenario for the circulatory system. Motivated by the assessment of the risks related to thrombus formation, here the impact of two different commercial endovascular grafts on local hemodynamics is explored through 20 image-based computational hemodynamic models of EVAR-treated patients (N = 10 per each endograft model). Hemodynamic features, susceptible to promote thrombus formation, such as flow separation and recirculation, are quantitatively assessed and compared with the local hemodynamics established in image-based infrarenal abdominal aortic models of healthy subjects (N = 10). Moreover, the durability of endovascular devices is investigated analyzing the displacement forces (DFs) acting on them. The hemodynamic analysis is complemented by a geometrical characterization of the EVAR-induced reshaping of the infrarenal abdominal aortic vascular region. The findings of this study indicate that (1) the clinically observed propensity to thrombus formation in devices used in EVAR strategies can be explained in terms of local hemodynamics by means of image-based computational hemodynamics approach; (2) reportedly prothrombotic hemodynamic structures are strongly associated with the geometry of the aortoiliac tract postoperatively; and (3) DFs are associated with cross-sectional area of the aortoiliac tract postoperatively. In perspective, our study suggests that future clinical followup studies could include a geometric analysis of the region of the implant, monitoring shape variations that can lead to hemodynamic disturbances of clinical significance.

17 April 2017 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
MMMiltiadis Matsagkas
Miltiadis Matsagkas
GKGeorge N. Kouvelos
George N. Kouvelos
KSKonstantinos Spanos
Konstantinos Spanos
AAAthanasios Athanasoulas
Athanasios Athanasoulas
AGAthanasios Giannoukas
Athanasios Giannoukas
Our goal was to evaluate the use of an AFX main body combined with an Endurant proximal aortic cuff to treat selected patients with an abdominal aortic aneurysm (AAA) associated with anatomical challenges, such as a small distal aortic diameter and a hostile aortic neck. A retrospective analysis of prospectively collected data from 2 vascular institutions identified 14 elective patients with an AAA (all men, 73.5 ± 5.1 years) treated with the AFX main body combined with an Endurant proximal aortic cuff. Patients had a small distal aortic diameter (median 19 mm) and a short or angulated proximal aortic neck (median length 20 mm, range 9–26 mm, median angulation 41.5°, range 23–80°). Six patients (42.9%) had an aortic neck that did not meet the indications for use of the AFX proximal aortic cuff. Primary technical success was achieved in all patients with no 30-day device-related complications or deaths. During a median follow-up period of 13 months (range 6-28 months), no re-intervention was needed. The diameter of the aneurysmal sac decreased from 57.6 ± 5.6 mm preoperatively to 50.4 ± 4.9 mm (P < 0.001) postoperatively. There were no aneurysm-related deaths or ruptures. No migration, disconnection or type I or III endoleak was observed. In 5 of the 6 patients, the initial type II endoleak spontaneously resolved during follow-up, whereas that in the remaining patient persisted without any change in the diameter of the aneurysmal sac. In patients with complex AAA anatomical configurations combining a hostile aortic neck and a narrow aortic bifurcation, the use of an AFX main body combined with an Endurant proximal aortic cuff seems to be feasible with favourable mid-term results.

8 January 2018 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
ARAnastasios Raptis
Anastasios Raptis
Michalis XenosMichalis Xenos
Michalis Xenos
GKGeorge N. Kouvelos
George N. Kouvelos
AGAthanasios Giannoukas
Athanasios Giannoukas
MMMiltiadis Matsagkas
Miltiadis Matsagkas
OBJECTIVESThe objective of this study is to analyse the flow conditions in the AFX and Nellix endografts (EGs) accounting for their postimplantation configuration in patients with an endovascular aneurysm repair-treated abdominal aortic aneurysm.METHODSWe reconstructed post-endovascular aneurysm repair computed tomography scans of patients treated with an AFX or Nellix EG creating post-implantation EG models. We examined 16 patients, 8 in each group. The blood flow properties were obtained by computational fluid dynamics simulations and were subsequently compared with physiological infrarenal blood flow properties measured in 5 healthy subjects. Specifically, pressure drop, maximum velocity and wall shear stress were measured at peak systole and mean helicity at mid-diastole.RESULTSOur statistical analyses showed that the haemodynamic properties in both control regions did not vary statistically after the implantation of either the AFX or the Nellix EG, except for helicity that was significantly lower in the abdominal part of the Nellix EG compared with the expected physiological measurement. Regardless of the overall blood flow restoration, it is important to note that low pressure drop was detected along the limbs of the AFX and suppressed blood helical motion was detected at the entrance of the Nellix device.CONCLUSIONSIt is observed from the results that the AFX EG has achieved absolute restoration of blood flow after endovascular aneurysm repair, although the development of secondary flow in the upper part of the EG and the low pressure drop in its limbs should be acknowledged. The Nellix EG also seems to be haemodynamically efficient. However, the suppression of helical flow before blood enters the device might raise concerns about its clinical application.

22 April 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
SKSpyridon Charilaos Katsoudas
Spyridon Charilaos Katsoudas
SMStavros Malatos
Stavros Malatos
ARAnastasios Raptis
Anastasios Raptis
MMMiltiadis Matsagkas
Miltiadis Matsagkas
Athanasios GiannoukasAthanasios Giannoukas
Athanasios Giannoukas
Michalis XenosMichalis Xenos
Michalis Xenos
Pathophysiological conditions in arteries, such as stenosis or aneurysms, have a great impact on blood flow dynamics enforcing the numerical study of such pathologies. Computational fluid dynamics (CFD) could provide the means for the calculation and interpretation of pressure and velocity fields, wall stresses, and important biomedical factors in such pathologies. Additionally, most of these pathological conditions are connected with geometric vessel changes. In this study, the numerical solution of the 2D flow in a branching artery and a multiscale model of 3D flow are presented utilizing CFD. In the 3D case, a multiscale approach (3D and 0D–1D) is pursued, in which a dynamically altered velocity parabolic profile is applied at the inlet of the geometry. The obtained waveforms are derived from a 0D–1D mathematical model of the entire arterial tree. The geometries of interest are patient-specific 3D reconstructed abdominal aortic aneurysms after fenestrated (FEVAR) and branched endovascular aneurysm repair (BEVAR). Critical hemodynamic parameters such as velocity, wall shear stress, time averaged wall shear stress, and local normalized helicity are presented, evaluated, and compared.

3 May 2017 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
ARAnastasios Raptis
Anastasios Raptis
Michalis XenosMichalis Xenos
Michalis Xenos
Efstratios GeorgakarakosEfstratios Georgakarakos
Efstratios Georgakarakos
GKGeorge N. Kouvelos
George N. Kouvelos
Athanasios GiannoukasAthanasios Giannoukas
Athanasios Giannoukas
MMMiltiadis Matsagkas
Miltiadis Matsagkas
Endovascular aneurysm repair (EVAR) is a clinically effective technique for treating anatomically eligible abdominal aortic aneurysms (AAAs), involving the deployment of an endograft (EG) that is designed to prevent blood leakage in the aneurysmal sac. While most EGs have equivalent operating principles, the hemodynamic environment established by different EGs is not necessarily the same. So, to unveil the post-EVAR hemodynamic properties, we need an EG-specific computational approach that currently lacks from the literature. Endurant and Excluder are two EGs with similar pre-installation designs. We assumed that the flow conditions in the particular EGs do not vary significantly. The hypothesis was tested combining image reconstructions, computational fluid dynamics (CFD), and statistics, taking into account the postimplantation position of the EGs. Ten patients with Endurant EGs and ten patients with Excluder EGs were included in this study. The two groups were matched with respect to the preoperative morphological characteristics of the AAAs. The EG models are derived from image reconstructions of postoperative computed tomography scans. Wall shear stress (WSS), displacement force, velocity, and helicity were calculated in regions of interest within the EG structures, i.e., the main body, the upper and lower part of the limbs. Excluder generated higher WSS compared to Endurant, especially on the lower part of the limbs (p = 0.001). Spatial fluctuations of WSS were observed on the upper part of the Excluder limbs. Higher blood velocity was induced by Excluder in all the regions of interest (p = 0.04, p = 0.01, and p = 0.004). Focal points of secondary flow were detected in the main body of Endurant and the limbs of Excluder. The displacement force acting on the lower part of the Excluder limbs was stronger compared to the Endurant one (p = 0.03). The results showed that two similar EGs implanted in similar AAAs can induce significantly different flow properties. The delineation of the hemodynamic features associated with the various commercially available EGs could further promote the personalization of treatment offered to aneurysmal patients and inspire ideas for the improvement of EG designs in the future.

1 October 2019 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
ARAnastasios Raptis
Anastasios Raptis
Michalis XenosMichalis Xenos
Michalis Xenos
KSKonstantinos Spanos
Konstantinos Spanos
GKGeorge N. Kouvelos
George N. Kouvelos
AGAthanasios Giannoukas
Athanasios Giannoukas
MMMiltiadis Matsagkas
Miltiadis Matsagkas