Guilherme Martini

Mr. Guilherme Martini

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GHGustavo de Oliveira Hoffmann
Gustavo de Oliveira Hoffmann
GMGuilherme Martini
Guilherme Martini
John G BuckleyJohn G Buckley
John G Buckley
ARAndre Rodacki
Andre Rodacki
The 2-Minute Step Test (2MST) is commonly scored by step count, which overlooks how the task is performed. This study tested whether a smartphone held to the thigh can be used to quantify thigh kinematics to determine 2MST outcome parameters, and whether a machine learning (ML) data analysis approach of the smartphone signal yields better agreement with motion capture (ground truth) compared to a more typical analytical data analysis approach (AA). Eighty-four healthy adults completed the 2MST while holding a smartphone against the right thigh. A thigh angular velocity ‘ground truth’ reference was obtained by simultaneous recording via motion capture (Vicon). Smartphone signals were resampled and processed using analytical (i.e., adaptive Butterworth filtering) and machine-learning data processing approaches (i.e., a stacked regression model trained to identify peak angular velocities). Step cycles and cycle duration were identical across equipment modalities and data analysis pipelines (mean 143 ± 18 cycles; 0.84 ± 0.11 s). However, the mean and variability of peak thigh angular velocity differed across the different modalities/pipelines (motion capture: 303 ± 39°·s−1; AA: 280 ± 47°·s−1; ML: 304 ± 37°·s−1). Bland–Altman agreement, compared to the ground truth measure, showed larger bias and limits of agreement for AA (bias 25.5°·s−1; −49.8–100.8) compared to ML (bias 1.0°·s−1; −15.4–17.5). These findings support using a smartphone held to the thigh to assess how the 2MST is performed, including providing the number and timing of steps completed and the average and variability in thigh angular velocity across cycles. Findings also suggest that a machine learning data analysis approach provides thigh angular velocity measures that are nearly identical to motion capture techniques, whereas a typical analytical data analysis approach has errors of around 8%.

5 November 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GHGustavo de Oliveira Hoffmann
Gustavo de Oliveira Hoffmann
TRThais Reichert
Thais Reichert
MEMatheus Henrique Esquelbeck
Matheus Henrique Esquelbeck
MGMayra Alejandra Camacho Gama
Mayra Alejandra Camacho Gama
GMGuilherme Martini
Guilherme Martini
ARAndré Luiz Felix Rodacki
André Luiz Felix Rodacki
Holding a smartphone against the thigh provides a simple means of instrumenting the Two-Minute Step Test (2MST), but it constrains arm swing and may affect movement, cardiovascular responses, and perceived exertion. This study examined whether holding a smartphone against the thigh during the 2MST alters thigh kinematics, heart rate response, or perceived exertion in healthy young adults. Forty-five participants (27 men and 18 women; 19.5 ± 2.6 years) performed the 2MST under two counterbalanced conditions: unrestricted arm swing, with the smartphone secured to the right thigh using an elastic pouch, and constrained arm swing, with the smartphone held against the right thigh and the opposite hand placed on the contralateral thigh. Smartphone gyroscope data were used to determine step cycles, mean thigh peak angular velocity, cycle duration, variability, and the rate of change in thigh peak angular velocity. Heart rate response and perceived exertion were also recorded. Paired comparisons were performed using appropriate tests with Bonferroni correction. Step cycle counts were similar between constrained and unrestricted conditions (131 ± 20 vs 127 ± 19 cycles; p = 0.091). Mean thigh peak angular velocity, cycle duration, rate of change in thigh peak angular velocity, cycle duration variability, and heart rate response did not differ between conditions. Thigh peak angular velocity variability was higher in the constrained condition (p < 0.01; effect size = 0.68). Perceived exertion was also slightly higher in the constrained condition (12.6 ± 1.8 vs 11.9 ± 2.1; p = 0.024), but the difference was below the minimal detectable change threshold. These findings indicate that holding a smartphone against the thigh does not meaningfully alter overall 2MST performance, most thigh kinematic outcomes, or heart rate response, supporting this practical smartphone-based protocol.