Juncheng Liang

Dr. Juncheng Liang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2015 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JLJuncheng Liang
Juncheng Liang
PZP. H. Zheng
P. H. Zheng
ZYZ. J. Yang
Z. J. Yang
HLH. R. Liu
H. R. Liu
MZM. Zhang
M. Zhang
QGQ. J. Guo
Q. J. Guo
Accurate measurement of radon and its progenies is the basis to control the radon dose and reduce the risk of lung cancer caused. The precise calibration of measuring instrument is an important part of the quality control of measurements of the concentration of radon and radon progenies. To establish Chinese national standards and realise reliable calibrations of measuring instrument for radon and its progenies, a radon chamber with regulation capability of environmental parameters, aerosol and radon concentrations was designed and constructed at National Institute of Metrology (NIM). The chamber has a total volume of ∼20 m3 including an exposure volume of 12.44 m3. The radon concentration can be controlled from 12 Bq m−3 to the maximum of 232 kBq m−3. The regulation range of temperature, relative humidity and aerosol are 0.66 –44.39°C, 16.4 –95 %RH and 102 –106 cm−3, respectively. The main advantages of the NIM radon chamber with respect to maintaining a stable concentration and equilibrium factor of radon progenies in a wide range through automatic regulation and control of radon and aerosol are described.

8 June 2022 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
QZQianqian Zhou
Qianqian Zhou
HLHaoran Liu
Haoran Liu
ZYZhijie Yang
Zhijie Yang
WZWeihua Zeng
Weihua Zeng
JLJuncheng Liang
Juncheng Liang

1 January 2013 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
AKAbdumomin Kadir
Abdumomin Kadir
LZLei Zhang
Lei Zhang
QGQiuju Guo
Qiuju Guo
JLJuncheng Liang
Juncheng Liang
Radon exposure to the public contributes more than half of all the radiation doses caused by natural radiation; accurate measurement of radon progeny is quite essential for the dose evaluation of radon exposure in environment. For the purpose of establishing a radon progeny standard and controlling measurement quality of commercial devices, it is quite important to analyze the efficiency of different measurement methods and determine which would be the most appropriate for radon progeny measurements. Through theoretical analysis and experimental measurement, some commonly used measurement methods were compared in this study and the development trends of those methods were reviewed. Results show that for radon progeny measurement, the spectroscopic analysis method is better than the gross count method, while least‐square calculation methods is better than traditional three‐count or five‐count method. Multiperiod counting of α plus β spectrum as well as using weighted least‐square calculation method might be the best choice for accurate measurement on radon progeny in standard radon chamber when calibrating commercial radon progeny monitors.

1 October 2024 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
YTYifan Tian
Yifan Tian
WZWeihua Zeng
Weihua Zeng
HLHaoran Liu
Haoran Liu
JLJuncheng Liang
Juncheng Liang
ZFZihao Fan
Zihao Fan
SHShengli Hou
Shengli Hou

1 April 2018 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
JLJuncheng Liang
Juncheng Liang
ZYZhijie Yang
Zhijie Yang
LWLiyuan Wang
Liyuan Wang
ZLZexi Li
Zexi Li
MZMing Zhang
Ming Zhang
DYDaqing Yuan
Daqing Yuan

6 December 2024 in Science of The Total Environment
Verified
Journal Article
Closed access
JLJing Luo
Jing Luo
YHYan Huang
Yan Huang
JLJinlong Lai
Jinlong Lai
JLJuncheng Liang
Juncheng Liang
XLXue-gang Luo
Xue-gang Luo
MZMin Zhao
Min Zhao