Rene Jaros

Dr. Rene Jaros

VSB–Technical University of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Cybernetics and Biomedical Engineering
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Open access
RKRadana Kahankova
Radana Kahankova
Radek MartinekRadek Martinek
Radek Martinek
RJRene Jaros
Rene Jaros
KBKhosrow Behbehani
Khosrow Behbehani
AMAdam Matonia
Adam Matonia
JBJoachim A. Behar
Joachim A. Behar
Fetal electrocardiography (fECG) is a promising alternative to cardiotocography continuous fetal monitoring. Robust extraction of the fetal signal from the abdominal mixture of maternal and fetal electrocardiograms presents the greatest challenge to effective fECG monitoring. This is mainly due to the low amplitude of the fetal versus maternal electrocardiogram and to the non-stationarity of the recorded signals. In this review, we highlight key developments in advanced signal processing algorithms for non-invasive fECG extraction and the available open access resources (databases and source code). In particular, we highlight the advantages and limitations of these algorithms as well as key parameters that must be set to ensure their optimal performance. Improving or combining the current or developing new advanced signal processing methods may enable morphological analysis of the fetal electrocardiogram, which today is only possible using the invasive scalp electrocardiography method.

30 May 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Radek MartinekRadek Martinek
Radek Martinek
RKRadana Kahankova
Radana Kahankova
JJJanusz Jezewski
Janusz Jezewski
RJRene Jaros
Rene Jaros
JMJitka Mohylova
Jitka Mohylova
HNHomer Nazeran
Homer Nazeran
Non-adaptive signal processing methods have been successfully applied to extract fetal electrocardiograms (fECGs) from maternal abdominal electrocardiograms (aECGs); and initial tests to evaluate the efficacy of these methods have been carried out by using synthetic data. Nevertheless, performance evaluation of such methods using real data is a much more challenging task and has neither been fully undertaken nor reported in the literature. Therefore, in this investigation, we aimed to compare the effectiveness of two popular non-adaptive methods (the ICA and PCA) to explore the non-invasive (NI) extraction (separation) of fECGs, also known as NI-fECGs from aECGs. The performance of these well-known methods was enhanced by an adaptive algorithm, compensating amplitude difference and time shift between the estimated components. We used real signals compiled in 12 recordings (real01–real12). Five of the recordings were from the publicly available database (PhysioNet-Abdominal and Direct Fetal Electrocardiogram Database), which included data recorded by multiple abdominal electrodes. Seven more recordings were acquired by measurements performed at the Institute of Medical Technology and Equipment, Zabrze, Poland. Therefore, in total we used 60 min of data (i.e., around 88,000 R waves) for our experiments. This dataset covers different gestational ages, fetal positions, fetal positions, maternal body mass indices (BMI), etc. Such a unique heterogeneous dataset of sufficient length combining continuous Fetal Scalp Electrode (FSE) acquired and abdominal ECG recordings allows for robust testing of the applied ICA and PCA methods. The performance of these signal separation methods was then comprehensively evaluated by comparing the fetal Heart Rate (fHR) values determined from the extracted fECGs with those calculated from the fECG signals recorded directly by means of a reference FSE. Additionally, we tested the possibility of non-invasive ST analysis (NI-STAN) by determining the T/QRS ratio. Our results demonstrated that even though these advanced signal processing methods are suitable for the non-invasive estimation and monitoring of the fHR information from maternal aECG signals, their utility for further morphological analysis of the extracted fECG signals remains questionable and warrants further work.

10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Radek MartinekRadek Martinek
Radek Martinek
MLMartina Ladrova
Martina Ladrova
MSMichaela Sidikova
Michaela Sidikova
RJRene Jaros
Rene Jaros
KBKhosrow Behbehani
Khosrow Behbehani
AKAleksandra Kawala-Sterniuk
Aleksandra Kawala-Sterniuk
Analysis of biomedical signals is a very challenging task involving implementation of various advanced signal processing methods. This area is rapidly developing. This paper is a Part III paper, where the most popular and efficient digital signal processing methods are presented. This paper covers the following bioelectrical signals and their processing methods: electromyography (EMG), electroneurography (ENG), electrogastrography (EGG), electrooculography (EOG), electroretinography (ERG), and electrohysterography (EHG).

27 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RJRene Jaros
Rene Jaros
Radek MartinekRadek Martinek
Radek Martinek
RKRadana Kahankova
Radana Kahankova
Fetal electrocardiography is among the most promising methods of modern electronic fetal monitoring. However, before they can be fully deployed in the clinical practice as a gold standard, the challenges associated with the signal quality must be solved. During the last two decades, a great amount of articles dealing with improving the quality of the fetal electrocardiogram signal acquired from the abdominal recordings have been introduced. This article aims to present an extensive literature survey of different non-adaptive signal processing methods applied for fetal electrocardiogram extraction and enhancement. It is limiting that a different non-adaptive method works well for each type of signal, but independent component analysis, principal component analysis and wavelet transforms are the most commonly published methods of signal processing and have good accuracy and speed of algorithms.

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Radek MartinekRadek Martinek
Radek Martinek
MLMartina Ladrova
Martina Ladrova
MSMichaela Sidikova
Michaela Sidikova
RJRene Jaros
Rene Jaros
KBKhosrow Behbehani
Khosrow Behbehani
AKAleksandra Kawala-Sterniuk
Aleksandra Kawala-Sterniuk
Advanced signal processing methods are one of the fastest developing scientific and technical areas of biomedical engineering with increasing usage in current clinical practice. This paper presents an extensive literature review of the methods for the digital signal processing of cardiac bioelectrical signals that are commonly applied in today’s clinical practice. This work covers the definition of bioelectrical signals. It also covers to the extreme extent of classical and advanced approaches to the alleviation of noise contamination such as digital adaptive and non-adaptive filtering, signal decomposition methods based on blind source separation and wavelet transform.

11 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
RJRene Jaros
Rene Jaros
Radek MartinekRadek Martinek
Radek Martinek
LDLukas Danys
Lukas Danys
This paper deals with transformations from electrocardiographic (ECG) to vectorcardiographic (VCG) leads. VCG provides better sensitivity, for example for the detection of myocardial infarction, ischemia, and hypertrophy. However, in clinical practice, measurement of VCG is not usually used because it requires additional electrodes placed on the patient’s body. Instead, mathematical transformations are used for deriving VCG from 12-leads ECG. In this work, Kors quasi-orthogonal transformation, inverse Dower transformation, Kors regression transformation, and linear regression-based transformations for deriving P wave (PLSV) and QRS complex (QLSV) are implemented and compared. These transformation methods were not yet compared before, so we have selected them for this paper. Transformation methods were compared for the data from the Physikalisch-Technische Bundesanstalt (PTB) database and their accuracy was evaluated using a mean squared error (MSE) and a correlation coefficient (R) between the derived and directly measured Frank’s leads. Based on the statistical analysis, Kors regression transformation was significantly more accurate for the derivation of the X and Y leads than the others. For the Z lead, there were no statistically significant differences in the medians between Kors regression transformation and the PLSV and QLSV methods. This paper thoroughly compared multiple VCG transformation methods to conventional VCG Frank’s orthogonal lead system, used in clinical practice.