Nina Maria Cornelia Mathijssen

Dr. Nina Maria Cornelia Mathijssen

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SMSophie Moerman
Sophie Moerman
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
DNDieu D. Niesten
Dieu D. Niesten
RRRoeland Riedijk
Roeland Riedijk
WRWillard J. Rijnberg
Willard J. Rijnberg
AVAnne J. H. Vochteloo
Anne J. H. Vochteloo
It is unclear whether cemented or uncemented hemiarthroplasty is the best treatment option in elderly patients with displaced femoral neck fractures. Previous randomized trials comparing cemented and uncemented hemiarthroplasty have conflicting results. We conducted a randomized controlled trial to compare cemented and uncemented hemiarthroplasty. This multicenter parallel-randomized controlled trial included patients of 70 years and older with a displaced femoral neck fracture (Garden type III or IV). Inclusion was between August 2008 and June 2012. Patients were randomized between a cemented hemiarthroplasty, type Müller Straight Stem or an uncemented hemiarthroplasty, type DB-10. Primary outcomes were complications, operation time, functional outcome (measured by Timed-Up-and-Go (TUG) and Groningen Activity Restriction Scale (GARS)) and mid-thigh pain. Health Related Quality of Life (HRQoL, expressed with the SF-12) was measured as an secondary outcome. Follow up was 1 year. In total 201 patients were included in the study (91 uncemented, 110 cemented hemiarthroplasties) The uncemented group showed more major local complications (intra- and postoperative fractures and dislocations) odds ratio (95% confidence interval) 3.36 (1.40 to 8.11). There was no difference in mean operation time (57.3 vs 55.4 min). There were no differences in functional outcomes (TUG 12.8 (9.4) vs. 13.9 (9.0), GARS 43.2 (19.7) vs. 39.2 (16.5)) and mid-thigh pain (18.6 vs 21.6%). Physical component SF-12 HRQoLwas lower in the uncemented group (30.3 vs. 35.3 p < 0.05 after six weeks, 33.8 vs 38.5 p < 0.05 after 12 weeks). A cemented hemiarthroplasty in elderly patients with a displaced femoral neck fracture results in less complications compared to an uncemented hemiarthroplasty. Netherlands Trial Registry; NTR 1508 , accepted date 27 okt 2008

19 December 2015 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
HVHennie Verburg
Hennie Verburg
CLCarsten C. G. van Leeuwen
Carsten C. G. van Leeuwen
TMTim L. Molenaar
Tim L. Molenaar
GHGerjon Hannink
Gerjon Hannink

14 October 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
BHB. Hesseling
B. Hesseling
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
LSL.N. van Steenbergen
L.N. van Steenbergen
MMMarijke Melles
Marijke Melles
SVS.B.W. Vehmeijer
S.B.W. Vehmeijer
JPJ.T. Porsius
J.T. Porsius
Background: The purpose of this study was to explore whether subgroups of patients with different functional recovery trajectories after total hip arthroplasty can be discerned, as well as their predictors, using data from the Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Implantaten [LROI]). Methods: We retrospectively reviewed prospectively collected Oxford Hip Scores (OHS) up to 1 year postoperatively for patients who had undergone a primary total hip arthroplasty. Latent class growth modeling was used to classify subgroups of patients according to the trajectory of functional recovery represented by the patients’ OHS. We used multivariable multinomial logistic regression analysis to explore factors associated with class membership. Results: A total of 6,030 patients were analyzed. Latent class growth modeling identified fast starters (fast initial improvement, high 12-month scores; 87.7%), slow starters (no initial change and subsequent improvement; 4.6%), and late dippers (initial improvement and subsequent deterioration; 7.7%). Factors associated with slow starters were female sex (odds ratio [OR], 1.63 [95% confidence interval (CI), 1.14 to 2.33]) and smoking (OR, 1.95 [95% CI, 1.26 to 3.03]); an anterior approach (OR, 0.47 [95% CI, 0.29 to 0.78]) had a protective effect against a less favorable response. Factors associated with late dippers were age of >75 years (OR, 1.62 [95% CI, 1.22 to 2.15]), smoking (OR, 1.68 [95% CI, 1.17 to 2.42]), American Society of Anesthesiologists (ASA) grade of III or IV (OR, 1.41 [95% CI, 1.05 to 1.91]), obesity (OR, 1.96 [95% CI, 1.43 to 2.69]), poorer EuroQol-5 Dimensions (EQ-5D) Self-Care (OR, 1.41 [95% CI, 1.09 to 1.82] for “some problems” and OR, 2.90 [95% CI, 1.39 to 6.03] for “unable”), poorer EQ-5D Anxiety/Depression (OR, 1.31 [95% CI, 1.00 to 1.71] for “moderately” and OR, 1.86 [95% CI, 1.06 to 3.24] for “extremely”), poorer EQ-5D visual analog scale (OR, 0.91 [95% CI, 0.86 to 0.97] per 10 points), direct lateral approach (OR, 2.18 [95% CI, 1.58 to 3.02]), and hybrid fixation with a cemented acetabular implant (OR, 1.79 [95% CI, 1.00 to 3.21]). Conclusions: We discerned fast starters, slow starters, and late dippers after total hip arthroplasty. Female sex, older age, obesity, higher ASA grades, and worse EQ-5D scores were associated with a less favorable response to total hip arthroplasty, as well as hybrid fixation (cemented acetabular implant) and direct lateral approach. Anterior approach had a protective effect against a less favorable response. However, all subgroups experienced functional improvement following total hip arthroplasty. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

4 March 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
HVH. Verburg
H. Verburg
NLN. J. London
N. J. London
MLM. Landsiedl
M. Landsiedl
MDM. Dominkus
M. Dominkus
More personalized implant designs for total knee arthroplasty might optimize the clinical outcome after surgery. One of these personalized implant designs is the Persona knee implant system (Zimmer Biomet, Warsaw, Indiana, USA). The primary objective of this study was to determine patient reported outcomes and implant survivorship of the Persona Knee system used in primary total knee arthroplasty, up to two years after surgery. From November 2013 to July 2016 consecutive patients undergoing primary total knee arthroplasty were enrolled in a prospective observational cohort study at three centers. Preoperatively, at 6 weeks, 6 months, 1 and 2 years after surgery, patients completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Oxford Knee Score (OKS), the Knee Society Score (KSS, 2011, modified version) and the EQ-5D. Adverse Events were captured, assessed for relationship to device, and recorded in the study database. Furthermore, physical functioning was assessed by the orthopedic surgeon. Repeated measures analyses were performed on PROM scores. Kaplan Meier was used to calculate survivorship of the Persona Knee Implant System. A total of 146 total knee arthroplasties were performed. 61% (89/146) of the patients were female and mean age was 64.7 (± 6.9) years. Two years after surgery, one patient had a revision of the polyethylene insert because of a periprosthetic joint infection. Therefore, the Kaplan-Meier survival estimate at 2 years was 0.99 (0.95–1.00 95% CI). OKS increased from 22.1 (95% CI 20.9–23.3) to 41.8 (95% CI 40.6–43.1) two years after surgery. Furthermore, all other PROMs also increased from before surgery to 2 year postoperatively. The Persona Knee implant is safe and effective and the clinical results up to two years after surgery are promising. PROMs results are very good; pain, function and quality of life all improved greatly after TKA. Further studies are needed to determine the long term clinical performance of the Persona prosthesis. Clinicaltrials.gov ( NCT02337244 ). Registered June 1st, 2015. Retrospectively registered.

7 January 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
PKPatrick Krastman
Patrick Krastman
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
SBSita M. A. Bierma-Zeinstra
Sita M. A. Bierma-Zeinstra
GKGerald Kraan
Gerald Kraan
JRJos Runhaar
Jos Runhaar
Background: The standard diagnostic work-up for hand and wrist fractures consists of history taking, physical examination and imaging if needed, but the supporting evidence for this work-up is limited. The purpose of this study was to systematically examine the diagnostic accuracy of tests for hand and wrist fractures.Methods: A systematic search for relevant studies was performed. Methodological quality was assessed and sensitivity (Se), specificity (Sp), accuracy, positive predictive value (PPV) and negative predictive value (NPV) were extracted from the eligible studies.Results: Of the 35 eligible studies, two described the diagnostic accuracy of history taking for hand and wrist fractures. Physical examination with or without radiological examination for diagnosing scaphoid fractures (five studies) showed Se, Sp, accuracy, PPV and NPV ranging from 15 to 100%, 13–98%, 55–73%, 14–73% and 75–100%, respectively. Physical examination with radiological examination for diagnosing other carpal bone fractures (one study) showed a Se of 100%, with the exception of the triquetrum (75%). Physical examination for diagnosing phalangeal and metacarpal fractures (one study) showed Se, Sp, accuracy, PPV and NPV ranging from 26 to 55%, 13–89%, 45–76%, 41–77% and 63–75%, respectively.Imaging modalities of scaphoid fractures showed predominantly low values for PPV and the highest values for Sp and NPV (24 studies). Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Ultrasonography (US) and Bone Scintigraphy (BS) were comparable in diagnostic accuracy for diagnosing a scaphoid fracture, with an accuracy ranging from 85 to 100%, 79–100%, 49–100% and 86–97%, respectively. Imaging for metacarpal and finger fractures showed Se, Sp, accuracy, PPV and NPV ranging from 73 to 100%, 78–100%, 70–100%, 79–100% and 70–100%, respectively.Conclusions: Only two studies were found on the diagnostic accuracy of history taking for hand and wrist fractures in the current review. Physical examination was of moderate use for diagnosing a scaphoid fracture and of limited use for diagnosing phalangeal, metacarpal and remaining carpal fractures. MRI, CT and BS were found to be moderately accurate for the definitive diagnosis of clinically suspected carpal fractures.

1 October 2016 in Surgical Infections
Verified
Journal Article
Closed access
NMNina Maria Cornelia Mathijssen
Nina Maria Cornelia Mathijssen
GHGerjon Hannink
Gerjon Hannink
PSPatrick D.J. Sturm
Patrick D.J. Sturm
PPPeter Pilot
Peter Pilot
RBRolf M. Bloem
Rolf M. Bloem
BSB. Willem Schreurs
B. Willem Schreurs
Background: The aim of this study was to investigate the effect of door opening rates on air quality in the operation room during hip revision surgery by measuring the number of colony forming units per cubic meter (CFU/m3). Methods: During 70 hip revision operations the number of CFU/m3 was measured at four time points. Factors that may influence air quality were recorded, including the number of persons present, duration of surgery, and door opening rates. The measured CFU/m3 was dichotomized as either acceptable (≤20 CFU/m3) or not acceptable (>20 CFU/m3). To determine whether door openings were associated with CFU/m3 values, we used generalized linear mixed models to model the dichotomized repeatedly measured CFU/m3 values. Results: The median number of door openings per operation was eight (range, 0–72), the median duration of surgery was 145 min (range, 60–285), and the median number of persons present during surgery was eight (range, 5–10). Adjusted for number of persons in the operation room and duration of surgery, the number of door openings per operation was associated (odds ratio [OR] 1.05 [95% confidence interval {CI} 1.02–1.09]; p = 0.003) with an unacceptable number of CFU/m3. Conclusions: In conclusion, a substantial association between number of door openings and an unacceptable number (>20) of CFU/m3 was found. Adjusted for number of persons in the operation room and duration of surgery, every door opening increased the odds of unacceptable CFU/m3 values by 5%. Number of persons present during surgery and duration of surgery were not related to CFU/m3.