Artificial intelligence has become increasingly integrated into medicine and surgery, yet much of its clinical impact has historically relied on models trained using low resolution and intermittently sampled data. High fidelity clinical data, defined by continuous acquisition, fine temporal resolution, and direct physiologic measurement, constitute a fundamentally different substrate for machine learning algorithms. Continuous monitoring tools such as near infrared spectroscopy and central venous oxygen saturations provide an uninterrupted stream of information that captures the dynamic behavior of human physiology. These data streams reveal complex patterns of physiologic compensation, adaptation, and eventual failure that remain largely invisible to traditional static clinical datasets. By tracking the delicate balance between oxygen delivery and systemic oxygen extraction in real time, clinicians can better understand the adequacy of perfusion before overt hemodynamic collapse occurs. When paired with machine learning methods capable of modeling temporal dependence, nonlinear interactions, and physiologic coupling, this rich stream of information enables a crucial transition from static risk prediction toward dynamic physiologic understanding. This chapter examines the conceptual foundations, analytic paradigms, data engineering requirements, and specific clinical applications of machine learning using high fidelity data, with particular emphasis on pediatric cardiovascular surgery and cardiac intensive care settings. Key methodologic challenges, interpretability considerations, and the ethical, regulatory, and operational constraints of deploying these computational models at the bedside are thoroughly discussed. The review concludes by highlighting future directions toward real time learning health systems and patient specific digital physiologic models that prioritize the continuous optimization of systemic oxygen delivery and extraction.
Background: The physiologic effects of vasoactive medications on the venous circulation remain incompletely understood. Contemporary bedside management often emphasizes the arterial circulation, whereas Guytonian physiology emphasizes the venous circulation and mean circulatory in determining steady-state cardiac output. The primary aim of this study was to characterize the effect of vasoactive medications on mean circulatory filling pressure and venous resistance. Methods: Demographic data and vasoactive data were collected from the electronic health record and collated with high-fidelity physiologic monitoring data. Mean circulatory filling pressure and venous resistance were calculated using clinically validated equations and then were modeled using a random forest regression incorporating postoperative time and infusion doses of epinephrine, norepinephrine, milrinone, vasopressin, phenylephrine, calcium, sodium nitroprusside, and nicardipine. Similar models were constructed for indexed systemic vascular resistance, cardiac index, cerebral oxygen extraction, and renal oxygen extraction. Results: Data from a total of 57 unique patients comprising 9,654,239 data points were analyzed. The model explained 91% of the variance in mean circulatory filling pressure and 58% of the variance in venous resistance. Vasopressin and norepinephrine were the most influential for mean circulatory filling pressure and venous resistance. Conclusion: Vasoactive medications modulate venous tone and impact mean circulatory filling pressure and venous resistance. High-fidelity physiologic data allow for characterizing these effects and guide titration of vasoactive medications at the bedside.
High-fidelity physiologic data provide an opportunity to characterize clinical physiology at temporal resolutions not available in conventional clinical datasets. Their use for research, however, is limited by substantial data-engineering and analytic requirements that are often recreated for each study. We developed a two-module workflow to automate recurring components of high-fidelity physiologic research while preserving investigator control over study design, physiologic definitions, model specification, and interpretation. The first module performs automated data collation. Patient- or event-level physiologic files are linked to a cohort dataset using persistent identifiers, source column names are programmatically identified and matched, physiologic signals are harmonized, redundant measurements are resolved according to prespecified rules, clinical metadata are propagated across physiologic observations, and absolute or event-relative time is established to create a standardized longitudinal analytic dataset. The collation module additionally quantifies missing-value burden and generates descriptive summaries, including the mean, standard deviation, median, and interquartile range, to facilitate data quality assurance and quality control before statistical analysis. A separate automated analysis module applies a mixed-effects modeling framework to the collated data. The initial implementation includes four analysis structures representing single-cohort or two-cohort studies aligned to either the beginning or end of a clinical event. Nonlinear trajectories may be modeled using spline functions, with patient or event incorporated as a random effect and additional covariates or sensitivity analyses included when appropriate. The current analysis types represent a practical starting framework rather than an exhaustive analytic library, and additional approaches can be incorporated as recurring scientific needs emerge. Because errors in automated workflows can propagate systematically across large datasets, validation of both modules and repeated validation following substantive updates are essential components of their development. This report describes the rationale, architecture, implementation, and practical considerations underlying this workflow for high-fidelity physiologic research.
Background: The physiologic effects of vasoactive medications on the venous circulation remain incompletely understood. Contemporary bedside management often emphasizes the arterial circulation, whereas Guytonian physiology emphasizes the venous circulation and mean circulatory filling pressure in determining steady-state cardiac output. The primary aim of this study was to characterize the effect of vasoactive medications on mean circulatory filling pressure and venous resistance. Methods: Demographic data and vasoactive data were collected from the electronic health record and collated with high-fidelity physiologic monitoring data. Mean circulatory filling pressure and venous resistance were calculated using clinically validated equations and then were modeled using a random forest regression incorporating postoperative time and infusion doses of epinephrine, norepinephrine, milrinone, vasopressin, phenylephrine, calcium, sodium nitroprusside, and nicardipine. Similar models were constructed for indexed systemic vascular resistance, cardiac index, cerebral oxygen extraction, and renal oxygen extraction. Results: Data from a total of 57 unique patients comprising 9,654,239 data points were analyzed. The model explained 57% of the variance in mean circulatory filling pressure and 59% of the variance in venous resistance. Vasopressin and norepinephrine were the most influential for mean circulatory filling pressure and venous resistance. Conclusions: Vasoactive medications appear to modulate venous tone and impact mean circulatory filling pressure and venous resistance. High-fidelity physiologic data allow for characterizing these effects and guide titration of vasoactive medications at the bedside.
Background: The aim of the study was to determine if there is an association between catheter-based occlusion of an arterial duct in premature infants and the incidence of necrotizing enterocolitis. Methods: This was a single center retrospective observational case control study. Infants born between 7/2018 and 12/2022, who were either born prior to 32 weeks gestation or weighed less than 1500 grams and had a patent arterial duct that received medical management, device closure, or surgical ligation were included. Group 1 consisted of infants born prior to 2020 who received only medical therapy and group 2 consisted of those who were born after 2020 and received catheter-based intervention. Analyses were conducted to determine if the incidence of necrotizing enterocolitis had changed since the introduction of catheter-based intervention at the institution in 2020. Results: There were 101 infants which met the inclusion criteria. Group 1 (n = 24) was prior to 2020 with medical management only, and group 2 (n = 77), 2020 onward with introduction of catheter-based occlusion. There were no significant changes in patient characteristics or any management options other than the introduction of device closure between the two groups. Development of necrotizing enterocolitis was shown to be at a median of 31 days and device closure at 49 days. There was a decreasing trend in the institutional incidence of necrotizing enterocolitis (2.6% vs 1.7%). Conclusion: Although we were unable to demonstrate statistical significance in the reduction of necrotizing enterocolitis between the groups, this may be due to the demonstrated need to intervene earlier as well as a larger sample size.