Christiane Thielemann

Prof. Christiane Thielemann


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
MMMargot Mayer
Margot Mayer
OAOnetsine Arrizabalaga
Onetsine Arrizabalaga
FLFlorian Lieb
Florian Lieb
MCManuel Ciba
Manuel Ciba
SRSylvia Ritter
Sylvia Ritter
CTChristiane Thielemann
Christiane Thielemann
Microelectrode array (MEA) technology in combination with three-dimensional (3D) neuronal cell models derived from human embryonic stem cells (hESC) provide an excellent tool for neurotoxicity screening. Yet, there are significant challenges in terms of data processing and analysis, since neuronal signals have very small amplitudes and the 3D structure enhances the level of background noise. Thus, neuronal signal analysis requires the application of highly sophisticated algorithms. In this study, we present a new approach optimized for the detection of spikes recorded from 3D neurospheres (NS) with a very low signal-to-noise ratio. This was achieved by extending simple threshold-based spike detection utilizing a highly sensitive algorithm named SWTTEO. This analysis procedure was applied to data obtained from hESC-derived NS grown on MEA chips. Specifically, we examined changes in the activity pattern occurring within the first ten days of electrical activity. We further analyzed the response of NS to the GABA receptor antagonist bicuculline. With this new algorithm method we obtained more reliable results compared to the simple threshold-based spike detection.

6 July 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CNC. Nick
C. Nick
SYS. Yadav
S. Yadav
RJR. Joshi
R. Joshi
JSJörg J Schneider
Jörg J Schneider
CTChristiane Thielemann
Christiane Thielemann
Electrodes based on carbon nanotubes are a promising approach to manufacture highly sensitive sensors with a low limit of signal detection and a high signal-to-noise ratio. This is achieved by dramatically increasing the electrochemical active surface area without increasing the overall geometrical dimensions. Typically, carbon nanotube electrodes are nearly planar and composed of randomly distributed carbon nanotube networks having a limited surface gain for a specific geometrical surface area. To overcome this limitation, we have introduced vertically aligned carbon nanotube (VACNT) networks as electrodes, which are arranged in a microelectrode pattern of 60 single electrodes. Each microelectrode features a very high aspect ratio of more than 300 and thus a dramatically increased surface area. These microelectrodes composed of VACNT networks display dramatically decreased impedance over the entire frequency range compared to planar microelectrodes caused by the enormous capacity increase. This is experimentally verified by electrochemical impedance spectroscopy and cyclic voltammetry.

1 April 2018 in Environmental Research
Verified
Journal Article
Open access
TKTim Köhler
Tim Köhler
MWMaximilian Wölfel
Maximilian Wölfel
MCManuel Ciba
Manuel Ciba
UBUlrich Bochtler
Ulrich Bochtler
CTChristiane Thielemann
Christiane Thielemann
Terrestrial Trunked Radio (TETRA) is a worldwide common mobile communication standard, used by authorities and organizations with security tasks. Previous studies reported on health effects of TETRA, with focus on the specific pulse frequency of 17.64 Hz, which affects calcium efflux in neuronal cells. Likewise among others, it was reported that TETRA affects heart rate variability, neurophysiology and leads to headaches. In contrast, other studies conclude that TETRA does not affect calcium efflux of cells and has no effect on people's health. In the present study we examine whether TETRA short- and long-term exposure could affect the electrophysiology of neuronal in vitro networks. Experiments were performed with a carrier frequency of 395 MHz, a pulse frequency of 17.64 Hz and a differential quaternary phase-shift keying (pi/4 DQPSK) modulation. Specific absorption rates (SAR) of 1.17 W/kg and 2.21 W/kg were applied. In conclusion, the present results do not indicate any effect of TETRA exposure on electrophysiology of neuronal in vitro networks, neither for short-term nor long-term exposure. This applies to the examined parameters spike rate, burst rate, burst duration and network synchrony.

1 November 2017 in Neural Computation
Verified
Journal Article
Closed access
RBR. Bestel
R. Bestel
Revathi AppaliRevathi Appali
Revathi Appali
Ursula van RienenUrsula van Rienen
Ursula van Rienen
CTChristiane Thielemann
Christiane Thielemann
Microelectrode arrays serve as an indispensable tool in electro-physiological research to study the electrical activity of neural cells, enabling measurements of single cell as well as network communication analysis. Recent experimental studies have reported that the neuronal geometry has an influence on electrical signaling and extracellular recordings. However, the corresponding mechanisms are not yet fully understood and require further investigation. Allowing systematic parameter studies, computational modeling provides the opportunity to examine the underlying effects that influence extracellular potentials. In this letter, we present an in silico single cell model to analyze the effect of geometrical variability on the extracellular electric potentials. We describe finite element models of a single neuron with varying geometric complexity in three-dimensional space. The electric potential generation of the neuron is modeled using Hodgkin-Huxley equations. The signal propagation is described with electro-quasi-static equations, and results are compared with corresponding cable equation descriptions. Our results show that both the geometric dimensions and the distribution of ion channels of a neuron are critical factors that significantly influence both the amplitude and shape of extracellular potentials.

17 September 2014 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
CNChristoph Nick
Christoph Nick
SYSandeep Yadav
Sandeep Yadav
RJRavi Joshi
Ravi Joshi
CTChristiane Thielemann
Christiane Thielemann
JSJörg J Schneider
Jörg J Schneider
The growth of cortical neurons on three dimensional structures of spatially defined (structured) randomly oriented, as well as on vertically aligned, carbon nanotubes (CNT) is studied. Cortical neurons are attracted towards both types of CNT nano-architectures. For both, neurons form clusters in close vicinity to the CNT structures whereupon the randomly oriented CNTs are more closely colonised than the CNT pillars. Neurons develop communication paths via neurites on both nanoarchitectures. These neuron cells attach preferentially on the CNT sidewalls of the vertically aligned CNT architecture instead than onto the tips of the individual CNT pillars.

12 April 2016 in Bioelectromagnetics
Verified
Journal Article
Closed access
PDF file
SOStefan Oster
Stefan Oster
ADAndreas W. Daus
Andreas W. Daus
CEChristian Erbes
Christian Erbes
MGMichael Goldhammer
Michael Goldhammer
UBUlrich Bochtler
Ulrich Bochtler
CTChristiane Thielemann
Christiane Thielemann