Los casos reportados de infección por Lactococcus garvieae son escasos y sólo uno asociado a hemodiálisis. Comunicamos el caso de endocarditis infecciosa de curso fatal por L. garvieae en un paciente con una enfermedad renal crónica sometido a hemodiálisis y portador de diverticulosis colónica no complicada. Se realiza una revisión de los casos publicados y se discuten los actuales desafíos diagnósticos y terapéuticos de este patógeno, capaz de producir infecciones graves y potencialmente fatales en pacientes susceptibles. Este sería el segundo caso de infección asociada a hemodiálisis y el primero reportado en Chile.
It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP).
The effectiveness against radiation of tungsten bismuth caps, used in interventional cardiology is not well known. To determine the degree of radiation protection conferred by these caps in real work conditions. We compared the gross electric charges received at brain lobe levels by three occupationally exposed professionals who participated in 22 consecutive procedures, inside and outside of the tungsten bismuth cap. The median electric charges outside and inside the cap were 3.71 (range 1.46-5.62) and 2.2 (range 1.29-3.93) nC, which correspond to a 40% radiation attenuation. However, the protection was heterogeneous. Tungsten bismuth caps provide an adequate attenuation, but its degree is heterogeneous.
22 May 2024 in Revista Chilena de Radiología (English Edition)
Background: The efficacy of radiation-attenuating lead-acrylic face masks used in interventional cardiology has been little studied. Objective: To determine ...
15 July 2024 in Journal of Radiological Protection
Background. Anecdotal reports are appearing in the scientific literature about cases of brain tumors in interventional physicians who are exposed to ionizing radiation. In response to this alarm, several designs of leaded caps have been made commercially available. However, the results reported on their efficacy are discordant. Objective. To synthesize, by means of a systematic review of the literature, the capacity of decreasing radiation levels conferred by radiation attenuating devices (RADs) at the cerebral level of interventional physicians. Methodology. A systematic review was performed including the following databases: MEDLINE, SCOPUS, EBSCO, Science Direct, Cochrane Controlled Trials Register (CENTRAL), WOS, WHO International Clinical Trials Register, Scielo and Google Scholar, considering original studies that evaluated the efficacy of RAD in experimental or clinical contexts from January 1990 to May 2023. Data selection and extraction were performed in triplicate, with a fourth author resolving discrepancies. Results. Twenty articles were included in the review from a total of 373 studies initially selected from the databases. From these, twelve studies were performed under clinical conditions encompassing 3801 fluoroscopically guided procedures, ten studies were performed under experimental conditions with phantoms, with a total of 88 procedures, four studies were performed using numerical calculations with a total of 63 procedures. The attenuation and effectiveness of provided by the caps analyzed in the present review varying from 12.3% to 99.9%, and 4.9% to 91% respectively. Conclusion. RAD were found to potentially provide radiation protection, but a high heterogeneity in the shielding afforded was found. This indicates the need for local assessment of cap efficiency according to the practice.