Claudio Chimenti

Claudio Chimenti

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2018 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
Michele TepedinoMichele Tepedino
Michele Tepedino
VPValeria Paoloni
Valeria Paoloni
PCPaola Cozza
Paola Cozza
CCClaudio Chimenti
Claudio Chimenti
Clear aligner treatment offers several advantages, but the available literature shows that some kind of tooth movements are unpredictable. In addition, the majority of the studies are focused on one clear aligner system, while different characteristics of various systems can provide different treatment outcomes. The aim of the present retrospective cohort study was to evaluate the predictability of Nuvola® aligner system in achieving torque movements of anterior teeth. Thirty-nine adult patients, who were consecutively treated with clear aligners, were retrospectively selected, and digital models pre-treatment (T0), post-treatment (T1) and the digital setup models (TS) were collected. Only the first phase of treatment made of 12 aligners was considered for the present study. Torque of anterior teeth was measured as labiolingual inclination on digital models at T0, T1, and TS using VAM software. Any difference between the predicted and achieved torque movements was evaluated using Wilcoxon signed-rank test or paired sample t test. First-type error was set as p < 0.008. No statistically significant difference was found for all the anterior teeth between predicted and achieved torque movements. The studied clear aligner system was able to produce clinical outcomes comparable to the planning of the digital setup relative to torque movements of the anterior teeth.

1 December 1997 in General and Comparative Endocrinology
Verified
Journal Article
Closed access
EME. Grassi Milano
E. Grassi Milano
FBF. Basari
F. Basari
CCClaudio Chimenti
Claudio Chimenti

1 October 2009 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
EPElena Di Palma
Elena Di Palma
Giulio GaspariniGiulio Gasparini
Giulio Gasparini
SPSandro Pelo
Sandro Pelo
Gianluca TartagliaGianluca Tartaglia
Gianluca Tartaglia
CCClaudio Chimenti
Claudio Chimenti

1 January 2016
Verified
Book Chapter
Closed access
VGValentina P Gallo
Valentina P Gallo
FAFiorenza Accordi
Fiorenza Accordi
CCClaudio Chimenti
Claudio Chimenti
ACAnnalena Civinini
Annalena Civinini
ECEnrico Crivellato
Enrico Crivellato

1 July 2012 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
DCDomenico Ciavarella
Domenico Ciavarella
VPVincenzo Parziale
Vincenzo Parziale
MMMario Mastrovincenzo
Mario Mastrovincenzo
APAntonio Palazzo
Antonio Palazzo
ASAntonio Sabatucci
Antonio Sabatucci
CCClaudio Chimenti
Claudio Chimenti

1 May 2005 in The Angle Orthodontist
Verified
Journal Article
Closed access
CCClaudio Chimenti
Claudio Chimenti
LFLorenzo Franchi
Lorenzo Franchi
MGMaria Grazia Di Giuseppe
Maria Grazia Di Giuseppe
MLMaria Lucci
Maria Lucci
The aim of this study was to evaluate in vitro the effect of variations in the size of elastomeric ligatures on the static frictional resistance generated by orthodontic sliding mechanics under dry condition. Frictional forces generated by elastomeric ligatures treated with a lubricating material (silicone) were analyzed as well. An Instron testing machine was used to assess the static frictional forces of a 0.019 x 0.025-inch stainless steel rectangular wire that was ligated to a molar convertible tube and to three stainless steel 0.022-inch pre-adjusted brackets with elastomeric ligatures with different dimensions: small, medium, and large. The static friction produced by two prototypes of silicone-lubricated elastomeric ligatures was also measured. The small and medium elastomeric ligatures produced significantly less friction than the large ligatures. No statistically significant difference was found between small and medium ligatures. The decrease in frictional forces of small and medium modules had to be ascribed mainly to the smaller thickness of both ligatures with respect to large ligatures. The lubricated elastomeric ligatures generated significantly smaller frictional forces than nonlubricated elastomeric ligatures with different dimensions. The variation in the dimensions of the elastomeric ligatures is able to influence the static frictional resistance generated by orthodontic sliding mechanics in the buccal segments. The use of small and medium elastomeric ligatures determines a 13-17% decrease in static friction compared with large ligatures. Silicone-lubricated modules can reduce static friction by 23-34% with respect to the small and medium nonlubricated elastomeric ligatures and by 36-43% compared with nonlubricated large ligatures.